Extubation during extracorporeal oxygenation (ECMO) in severe acute respiratory distress syndrome (ARDS) has not been well studied. Despite the potential benefits of this strategy, weaning from ECMO before liberation from invasive mechanical ventilation remains the most frequent approach. Our aim was to evaluate the safety and feasibility of a standardized approach for extubation during ECMO in patients with severe ARDS. We conducted a prospective observational study to assess the safety and feasibility of a standardized approach for extubation during ECMO in severe ARDS among 254 adult patients across 4 intensive care units (ICU) from 2 tertiary ECMO centers over 6 years. This consisted of a daily assessment of clinical and gas exchange criteria based on an Extracorporeal Life Support Organization guideline, with extubation during ECMO after validation by a dedicated intensive care medicine specialist. Fifty-four (21%) patients were extubated during ECMO, 167 (66%) did not reach the clinical criteria, and in 33 (13%) patients, gas exchange precluded extubation during ECMO. At ECMO initiation, there were fewer extrapulmonary organ dysfunctions (lower SOFA score [OR, 0.88; 95% CI, 0.79–0.98; P = .02] with similar PaO2/FiO2) when compared with patients not extubated during ECMO. Extubation during ECMO associated with shorter duration of invasive mechanical ventilation (7 (4–18) vs. 32 (18–54) days; P < .01) and of ECMO (12 (7–25) vs. 19 (10–41) days; P = .01). This was accompanied by a lower incidence of hemorrhagic shock (2 vs. 11%; P = .05), but more cannula-associated deep vein thrombosis (49 vs. 31%; P = .02) and failed extubation (20 vs. 6%; P < .01). There were no increased major adverse events. Extubation during ECMO is associated with a lower risk of all-cause death, independently of measured confounding (adjusted logistic regression OR 0.23; 95% confidence interval 0.08–0.69, P = .008). A standardized approach was safe and feasible allowing extubation during ECMO in 21% of patients with severe ARDS, selecting patients who will have a shorter duration of invasive mechanical ventilation, ECMO course, and ICU stay, as well as fewer infectious complications, and high hospital survival.
Urban mobility is a massive issue in the current century, being widely promoted the need of adopting sustainable solutions regarding transportation within large urban centres. The evolution of technologies has democratised smart cities to better plan and manage their mobility solutions, without compromising the social, economic, and environmental impacts. Pursuing the carbon neutrality and the climate agreement goals, soft mobility is one of the most popular emerging methods to provide greener alternatives regarding mobility. Among these transportation modes are the bicycle, which has been widely used in several public systems across the world, one of them being in Lisbon. This article provides a decision support system for bike-sharing docking stations for three council parishes of the city, namely, Parque das Nações, Marvila, and Beato. Taking advantage of clustering methods and GSM data from a telecommunication operator, this study pretends to highlight a novel approach to identify soft mobility hotspots, in specific bike-sharing docking stations, for suited mobility management systems in Lisbon’s city centre.
Background: The urgent need for mechanical ventilators to support respiratory insufficiency due to SARS-CoV-2 led to a worldwide effort to develop low-cost, easily assembled, and locally manufactured ventilators. The ATENA ventilator project was developed in a community-based approach targeting the development, prototyping, testing, and decentralized manufacturing of a new mechanical ventilator.Objective: This article aims to demonstrate ATENA's adequate performance and safety for clinical use.Material: ATENA is a low-cost ventilator that can be rapidly manufactured, easily assembled, and locally produced anywhere in the world. It was developed following the guidelines and requirements provided by European and International Regulatory Authorities (MHRA, ISO 86201) and National Authorities (INFARMED). The device was thoroughly tested using laboratory lung simulators and animal models.Results: The device meets all the regulatory requirements for pandemic ventilators. Additionally, the pre-clinical experiences demonstrated security and adequate ventilation and oxygenation, in vivo.Conclusion: The ATENA ventilator had a good performance in required tests in laboratory scenarios and pre-clinical studies. In a pandemic context, ATENA is perfectly suited for safely treating patients in need of mechanical ventilation.