Aims: Cardiovascular diseases manifest differently in males and females, potentially influenced by inherent sex- and age-related differences in myocardial tissue composition. Such inherent differences are not well-established in the literature. With this study using cardiac magnetic resonance (CMR) native T1 mapping, we aim to determine the effect of sex and age on myocardial tissue composition in healthy individuals. Methods and results: CMR native T1 mapping was performed in 276 healthy individuals (55% male, age 8–84 years) on a 1.5 Tesla scanner using a MOLLI 5(3)3 acquisition scheme. Additionally, 30 healthy participants (47% male, age 24–68 years) underwent a 1-year follow-up CMR to assess the longitudinal changes of native T1. Mean native T1 values were 1000 ± 22 ms in males and 1022 ± 23 ms in females [mean difference (MD) = 22 ms, 95% confidence interval (CI) (17, 27)]. Female sex was associated with higher native T1 in multivariable linear regression adjusting for age, heart rate, left ventricular mass index, and blood T1 [β=10 ms, 95% CI (3.4, 15.8)]. There was no significant interaction between sex and age (P = 0.27). Further, age was not associated with native T1 [β=0.1 ms, 95% CI (−0.02, 0.2)], and native T1 did not change during a 1-year period [MD −4 ms, 95% CI (−11, 3)]. Conclusion: Female sex was associated with higher native T1; however, there was no association between age and native T1. Additionally, there was no evidence of an interaction between sex and age. Our findings indicate intrinsic sex-based disparities in myocardial tissue composition.
Increased left ventricular mass (LVM) is a strong independent predictor for adverse cardiovascular events, but conventional echocardiographic methods are limited by poor reproducibility and accuracy. We developed a novel method based on adding the mean wall thickness from the parasternal short axis view, to the left ventricular end-diastolic volume acquired using the biplane model of discs. The participants (n = 85) had various left ventricular geometries and were assessed using echocardiography followed immediately by cardiac magnetic resonance, as reference. We compared our novel two-dimensional (2D) method to various conventional one-dimensional (1D) and other 2D methods as well as the three-dimensional (3D) method. Our novel method had better reproducibility in intra-examiner [coefficients of variation (CV) 9% vs. 11–14%] and inter-examiner analysis (CV 9% vs. 10–20%). Accuracy was similar to the 3D method (mean difference ± 95% limits of agreement, CV): Novel: 2 ± 50 g, 15% vs. 3D: 2 ± 51 g, 16%; and better than the “linear” 1D method by Devereux (7 ± 76 g, 23%). Our novel method is simple, has considerable better reproducibility and accuracy than conventional “linear” 1D methods, and similar accuracy as the 3D-method. As the biplane model forms part of the standard echocardiographic protocol, it does not require specific training and provides a supplement to the modern echocardiographic report.
Left ventricular (LV) mass (LVM) is a predictor of cardiovascular morbidity and mortality and commonly calculated using 1-dimensional (1D) echocardiographic methods. These methods are vulnerable to small measurement errors and LVM may wrongly change according to changes in LV volume (LVV). Less commonly used 2-dimensional (2D) methods can accommodate to the changes in LVV and may be a better alternative among patients receiving hemodialysis (HD) with large fluid fluctuations. Observational study. Patients with end-stage kidney disease receiving HD. One HD session. Transthoracic echocardiography was performed right before and after HD. LVM was calculated using 1D (Devereux, Penn, and Teichholz) and 2D methods (truncated ellipsoid and area-length). Significant differences in LVM after HD. We compared dimensions, LVV and LVM, in 53 patients (mean age, 63 ± 15 years; 66% men). For each 1-L increase in ultrafiltration volume (UFV), LV internal diameter decreased 1.1 mm (95% CI, 0.5-1.7 mm; P = 0.001). Patients were divided into 2 groups by the median UFV of 1.6 L. Patients with UFV > 1.6 L had significant smaller LVV and LV internal diameter after HD. LVM calculated using 1D methods decreased according to changes in LVV. Conversely, LVM calculated using 2D methods was not significantly different after HD. No significant change in differences between diastolic − systolic myocardial thickness or LVM as assessed using 1D and 2D methods was observed before and after HD, indicating that LVM remained constant despite HD. We did not use contrast enhancement, 3-dimensional methods, or cardiac magnetic resonance. LVM calculated using 2D methods, truncated ellipsoid and area-length, is less affected by fluctuations in fluid and LVV, in contrast to 1D methods. Complementary LVM calculation using 2D methods is encouraged, especially in patients with large fluid fluctuations in which increased LVM using a 1D method has been detected.
16 April 2025 in European Heart Journal - Digital Health
Aims: This study aimed to test whether seismocardiography (SCG) can detect changes in loading conditions and detect significant differences in SCG signals between healthy individuals and those with cardiovascular disease (CVD). Methods and results: Twenty-six subjects (age 45 ± 16 years and 77% male) were included, 11 healthy subjects and 15 subjects with CVD. SCG was compared with transthoracic echocardiography (TTE) before and after infusion of 2 L of isotonic saline. Nine subjects (34%) with CVD did not tolerate the full infusion (2 L infusion intolerant), while the remaining 17 subjects (2 L infusion tolerant) successfully completed the infusion. Significant changes in SCG measurements were observed after infusion, including amplitudes Ls (19%, P = 0.015), Dd (23%, P = 0.016), and Ed (48%, P < 0.001) as well as most time intervals. TTE measurements also showed post-infusion changes in stroke volume (15%, P = 0.038), mitral annular velocity (7%, P = 0.013), left ventricular ejection time (1%, P = 0.035), and global longitudinal strain (6%, P = 0.003). Although SCG did not detect differences between the healthy and CVD groups, the diastolic amplitude Cd-Dd significantly differed between the infusion tolerant and intolerant groups (pre-infusion: 7.7 vs. 3.7 mg, P = 0.046; post-infusion: 8.3 vs. 4.1 mg, P = 0.034). Conclusion: SCG can detect changes in pre-load in both healthy subjects and subjects with CVD. SCG were also able to detect differences in SCG diastolic amplitudes between infusion-tolerant and -intolerant subjects, which may indicate ability to detect diastolic dysfunction and differences in left ventricular filling pressures.
(1) Background: To investigate how food intake and preload augmentation affect the cardiac output (CO) and volumes of the left ventricle (LV) and right ventricle (RV) assessed using cardiac magnetic resonance (CMR) and trans-thoracic echocardiography (TTE). (2) Methods: Eighty-two subjects with (n = 40) and without (n = 42) cardiac disease were assessed using both CMR and TTE immediately before and after a fast infusion of 2 L isotonic saline. Half of the population had a meal during saline infusion (food/fluid), and the other half were kept fasting (fasting/fluid). We analyzed end-diastolic (EDV) and end-systolic (ESV) volumes and feature tracking (FT) using CMR, LV global longitudinal strain (GLS), and RV longitudinal strain (LS) using TTE. (3) Results: CO assessed using CMR increased significantly in both groups, and the increase was significantly higher in the food/fluid group: LV-CO (ΔLV-CO: +2.6 ± 1.3 vs. +0.7 ± 1.0 p < 0.001), followed by increased heart rate (HR) (ΔHR: +12 ± 8 vs. +1 ± 6 p < 0.001). LV and RV achieved increased stroke volume (SV) through different mechanisms. For the LV, through increased contractility, increased LV-EDV, decreased LV-ESV, increased LV-FT, and GLS were observed. For the RV, increased volumes, increased RV-EDV, increased RV-ESV, and at least for the fasting/fluid group, unchanged RV-FT and RV-LS were reported. (4) Conclusions: Preload augmentation and food intake have a significant impact on hemodynamic and cardiac functional parameters. This advocates for standardized recommendations regarding oral intake of fluid and food before cardiac assessment, for example, TTE, CMR, and right heart catheterization. We also demonstrate different approaches for the LV and RV to increase SV: for the LV by increased contractility, and for the RV by volume expansion.
3 May 2022 in Frontiers in Cardiovascular Medicine
Introduction: Increased left ventricular mass (LVM) is one of the most powerful predictors of adverse cardiovascular events. Clinical evaluation requires reliable, accurate and reproducible echocardiographic LVM-quantification to manage patients. For this purpose, we have developed a novel two-dimensional (2D) method based on adding the mean wall thickness to the left ventricular volume acquired by the biplane method of disks, which has recently been validated in humans using cardiac magnetic resonance as reference value. We assessed the hypothesis that the novel method has better accuracy than conventional one-dimensional (1D) methods, when compared to necropsy LVM in pigs.Materials and Methods: Echocardiography was performed during anesthesia in 34 Danish Landrace pigs, weight 47–59 kg. All pigs were euthanized, cardiac necropsy was performed and the left ventricle was trimmed and weighed for necropsy LVM. Trans-thoracic echocardiography was applied for parasternal images. Transdiaphragmal echocardiography was applied for the apical images, which are otherwise difficult to obtain in pigs. We compared the conventional 1D- and 2D-methods and the novel 2D-method to the LVM from cardiac necropsy.Results: Necropsy LVM was 132 ± 11 g (mean ± SD). The novel method had better accuracy than other methods (mean difference ± 95% limits of agreement; coefficients of variation; standard error of the estimate, Pearson's correlation). Novel (−1 ± 20 g; 8%; 11 g; r = 0.70), Devereux (+26 ± 37 g; 15%; 33 g; r = 0.52), Area-Length (+27 ± 34 g; 13 %; 33 g; r = 0.63), Truncated Ellipsoid (+10 ± 30 g; 12%; 19 g; r = 0.63), biplane endo-/epicardial tracing (−3 ± 2 g; 10%; 14 g; r = 0.57). No proportional bias in linear regression was detected for any method, when compared to necropsy LVM.Conclusion: We confirm high accuracy of the novel 2D-based method compared to conventional 1D/2D-methods.