Following the 2013/59/EURATOM Directive, the Italian 101/2020 Decree Law lowered the annual limit on the equivalent dose to eye lens from 150 to 20 mSv for exposed workers, in order to limit the risk of radiation-induced cataract. Such a drastic reduction makes it very important to perform accurate dose monitoring for medical staff that works with ionizing radiation as interventional radiologists and cardiologists. The standard for occupational eye lens dosimetry consists into Hp(3) calibrated dosimeters placed on physicians glasses, next to the eyes. However, this dosimetry system suffers calibration issues, and therefore, the dose is usually extrapolated from extremity or whole body measurements, leading to low accuracy. Chips of thermoluminescent dosimeters TLD-100 and dedicated Hp(3) calibrated dosimeters were placed over a plexiglas (PMMA) phantom to measure the Entrance Surface Air Kerma (Ke) and the eye lens equivalent dose (H) to physician, respectively, during simulated interventional radiology procedures. Values were all below the regulatory limit. Our results show that TLD-100’s response seems to be correlated with Hp(3) according to the relationship Ke = F × H, with an average factor F = 3.9 mGy/mSv, opening the possibility of using both dosimeters for accurate radiation protection of exposed workers.
Drinking water, in addition to the best-known chemical and biological agents, contains radionuclides of both natural and artificial origin, which can contribute significantly to the overall effective dose received by the population. The Italian Decree Law 28/2016, implementing the 2013/51/EURATOM Directive, establishes the activities for risk management and the parameter values for different radionuclide activity concentrations. In addition to the institutions involved, the National Inspectorate for Nuclear Safety and Radiation Protection (ISIN) annually publishes monitoring reports of environmental radioactivity in Italy, including radioactivity in drinking water. The purpose of the study was to integrate ISIN reports with 2018–2020 data by collecting measurements performed by institutional laboratories to obtain more complete information and adding, for the Campania region, some data not yet published. This new updated report was not significantly different from ISIN’s one, meaning that those publications are nevertheless extremely representative of the radioactivity in Italian drinking water. However, the study allowed us to obtain more detailed data, including measurements not considered in ISIN reports, for instance, radon-222 activity concentrations. This may be of great usefulness for all radiation protection stakeholders in order to ensure environmental protection, pollution prevention, and population safety.
Interventional radiology offers minimally invasive procedures guided by real-time imaging, reducing surgical risks and enhancing patient recovery. While beneficial to patients, these advancements increase occupational hazards for physicians due to chronic exposure to ionizing radiation. This exposure raises health risks like radiation-induced cataracts, cardiovascular disease, and cancer. Despite regulations like the European Council Directive 2013/59/EURATOM, which sets limits on whole-body and eye lens doses, no dose limits exist for the brain and meninges, since the brain has traditionally been considered a radioresistant organ. Recent studies, however, have highlighted radiation-induced brain damage, suggesting that meningeal exposure in interventional radiology may be underestimated. This study evaluates the entrance air Cumulative mean annual entrance air kerma to the skullull during interventional radiology procedures, using thermoluminescent dosimeters and controlled exposure simulations. Data were collected by varying the exposure time and analyzing the contribution to the entrance air kerma on each side of the head. The results indicate that, considering the attenuation of the cranial bone, the absorbed dose to the brain, obtained by averaging the head entrance air kerma for the right, front, and left sides of the operator’s head, could represent 0.81% to 2.18% of the annual regulatory limit in Italy of 20 mSv for the average annual effective dose of exposed workers (LD 101/2020). These results provide an assessment of brain exposure, highlighting the relatively low but non-negligible contribution of brain irradiation to the overall occupational dose constraint. Additionally, a correlation between entrance air kerma and the Kerma-Area Product was observed, providing a potential method for improved dose estimation and enhanced radiation safety for interventional radiologists.
Surface brachytherapy (BT) lacks standard quality assurance (QA) protocols. Commercially available treatment planning systems (TPSs) are based on a dose calculation formalism that assumes the patient is made of water, resulting in potential deviations between planned and delivered doses. Here, a method for treatment plan verification for skin surface BT is reported. Chips of thermoluminescent dosimeters (TLDs) were used for dose point measurements. High-dose-rate treatments were simulated and delivered through a custom-flap applicator provided with four fixed catheters to guide the Iridium-192 (Ir-192) source by way of a remote afterloading system. A flat water-equivalent phantom was used to simulate patient skin. Elekta TPS Oncentra Brachy was used for planning. TLDs were calibrated to Ir-192 through an indirect method of linear interpolation between calibration factors (CFs) measured for 250 kV X-rays, Cesium-137, and Cobalt-60. Subsequently, plans were designed and delivered to test the reproducibility of the irradiation set-up and to make comparisons between planned and delivered dose. The obtained CF for Ir-192 was (4.96 ± 0.25) μC/Gy. Deviations between measured and TPS calculated doses for multi-catheter treatment configuration ranged from −8.4% to 13.3% with an average of 0.6%. TLDs could be included in clinical practice for QA in skin BT with a customized flap applicator.
Drinking water, in addition to the best-known chemical and biological agents, contains radionuclides of both natural and artificial origin, which can contribute significantly to the overall effective dose received by the population. The Italian Decree Law 28/2016, implementing 2013/51/EURATOM Directive, establishes the activities for risk management and the parameter values for different radionuclides activity concentrations. In addition to the institutions involved, annually the National Inspectorate for Nuclear Safety and Radiation Protection (ISIN), publishes the monitoring reports of environmental radioactivity in Italy, including radioactivity in drinking water. The purpose of the study was to integrate ISIN reports with 2018 to 2020 data by collecting measurements performed by institutional laboratories to obtain a more complete information and adding, for the Campania region, some data not yet published. This new updated report was not significantly different from ISIN’s one, meaning that those publications are nevertheless extremely representative of the radioactivity in Italian drinking water. However, the study allowed to obtain a more detailed data also including measurements not considered in ISIN reports, for instance, radon-222 activity concentrations. This may be of great usefulness for all radiation protection stakeholders in order to ensure environmental protection, pollution prevention and the population safety.