Chiara Tuma

Ms. Chiara Tuma

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2023 in Nutrients
Verified
Journal Article
Open access
PDF file
CTChiara Tuma
Chiara Tuma
ASArne Schick
Arne Schick
NPNele Pommerening
Nele Pommerening
HBHans Braun
Hans Braun
MTMario Thevis
Mario Thevis
Vitamin D is crucial to the health and performance of athletes. Although the exact vitamin D requirements for athletes have not been established, maintaining a 25(OH)D level of at least 40 ng/mL is considered beneficial. This randomized controlled intervention study aimed to determine whether an individual loading dose formula for vitamin D supplementation is more effective than standardized supplementation and suitable enough for athletes to meet a target value of 40 ng/mL. In a 10-week supplementation study conducted during the winter months in Germany, 90 athletes with insufficient vitamin D levels (25(OH)D < 30 ng/mL) were randomly assigned to receive either a universal dose of 2000 IU/day of vitamin D or a loading dose of 4000 IU/day, followed by a maintenance dose of 1000 IU/day. The total 25(OH)D concentration was measured from dried blood spots at three time points: at baseline, at the computed date of 40 ng/mL, and after the 10-week period. Additionally, a vitamin-D-specific questionnaire was issued. On the day when 25(OH)D blood concentrations of 40 ng/mL were calculated to prevail, the individualized group had a significantly higher 25(OH)D level than the standardized group (41.1 ± 10.9 ng/mL vs. 32.5 ± 6.4 ng/mL, p < 0.001). This study demonstrated that the examined formula is suitable enough for athletes to achieve a 25(OH)D concentration of 40 ng/mL. This indicates that a personalized approach is more effective than a one-size-fits-all approach in restoring adequate vitamin D levels in athletes.

12 June 2024 in Metabolites
Verified
Journal Article
Open access
PDF file
CTChiara Tuma
Chiara Tuma
ATAndreas Thomas
Andreas Thomas
HBHans Braun
Hans Braun
MTMario Thevis
Mario Thevis
Relative energy deficiency in sport (RED-S) is a condition that arises from persistent low energy availability (LEA), which affects the hypothalamic–pituitary axis and results in alterations of several hormones in both male and female athletes. As frequent blood hormone status determinations using venipuncture are rare in sports practice, microsampling offers promising possibilities for preventing and assessing RED-S. Therefore, this study aimed at developing a liquid chromatography–high-resolution tandem mass spectrometry (LC-HRMS/MS) method for quantifying relevant steroids and thyroid hormones in 30 μL of capillary blood obtained using Mitra® devices with volumetric absorptive microsampling technology (VAMS®). The results of the study showed that all validation criteria were met, including a storage stability of more than 28 days in a frozen state (−18 °C) and 14 days at room temperature (20 °C). The validated assay provided precise (<12%) and accurate (<13%) results for all the target analytes. Furthermore, as a proof of concept, autonomously collected VAMS® samples from 50 female and male, healthy, active adults were analyzed. The sensitivity of all analytes was adequate to quantify the decreased hormone concentrations in the RED-S state, as all authentic samples could be measured accordingly. These findings suggest that self-collected VAMS® samples offer a practical opportunity for regular hormone measurements in athletes and can be used for early RED-S assessment and progress monitoring during RED-S recovery.

1 January 2024 in International Journal of Sport Nutrition and Exercise Metabolism
Verified
Journal Article
Closed access
PDF file
CTChiara Tuma
Chiara Tuma
ATAndreas Thomas
Andreas Thomas
LTLasse Trede
Lasse Trede
HBHans Braun
Hans Braun
MTMario Thevis
Mario Thevis
This article has been retracted as of July 17, 2024, after a reader expressed concern that maximum caffeine concentrations in the study were substantially higher than those in earlier reports. The authors of the original article were asked to provide their raw dataset and an explanation for the apparent inconsistencies. During an independent review of the study data in coordination with the authors, they identified a contamination issue with caffeine that affected their evaluation of the results. Because the plausibility of the present data is in doubt due to the contamination issue, the article is retracted.

27 October 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
CTChiara Tuma
Chiara Tuma
ASArne Schick
Arne Schick
NPNele Pommerening
Nele Pommerening
HBHans Braun
Hans Braun
MTMario Thevis
Mario Thevis
Vitamin D is crucial for athletes' health and performance. Although the exact vitamin D requirements for athletes have not been established, maintaining 25(OH)D levels of at least 40 ng/ml is considered beneficial. This study aimed to determine whether an individual loading dose formula for vitamin D supplementation is suitable to meet a target value of 40 ng/ml and is more effective than standardized supplementation. In a 10-week supplementation study during the winter months in Germany, 90 athletes with insufficient vitamin D levels (25(OH)D<30ng/ml) were randomly assigned to receive either a universal dose of 2000 IU/day of vitamin D or a loading dose of 4000 IU/day, followed by a maintenance dose of 1000 IU/day. Total 25(OH)D concentration was measured from dried blood spots at three time points: at baseline, at the computed date of 40ng/ml, and after the 10-week period. Additionally, a vitamin D-specific questionnaire was issued. On the day when 25(OH)D blood concentrations of 40 ng/ml were calculated to prevail, the individualized group had a significantly higher 25(OH)D level than the standardized group (41.1+-10.9 ng/ml vs. 32.5+-6.4 ng/ml, p<0.001). This study demonstrated that the examined formula is suitable for athletes to achieve a 25(OH)D concentration of 40 ng/ml. This indicates that a personalized approach is more effective than a one-size-fits-all approach in restoring adequate vitamin D levels in athletes.