Background: The prosthetic socket is a key component that influences prosthesis satisfaction, with a poorly fitting prosthetic socket linked to prosthesis abandonment and reduced community participation. This paper reviews adjustable socket designs, as they have the potential to improve prosthetic fit and comfort through accommodating residual limb volume fluctuations and alleviating undue socket pressure. Methods: Systematic literature and patent searches were conducted across multiple databases to identify articles and patents that discussed adjustable prosthetic sockets. The patents were used to find companies, organisations, and institutions who currently sell adjustable sockets or who are developing devices. Results: 50 literature articles and 63 patents were identified for inclusion, representing 35 different designs used in literature and 16 commercially available products. Adjustable sockets are becoming more prevalent with 73% of publications (literature, patents, and news) occurring within the last ten years. Two key design characteristics were identified: principle of adjustability (inflatable bladders, moveable panels, circumferential adjustment, variable length), and surface form (conformable, rigid multi-DOF, and rigid single DOF). Inflatable bladders contributed to 40% of literature used designs with only one identified commercially available design (n = 16) using this approach. Whereas circumferential adjustment designs covered 75% of identified industry designs compared to only 36% of literature devices. Clinical studies were generally small in size and only 17.6% of them assessed a commercially available socket. Discussion: There are clear differences in the design focus taken by industry and researchers, with justification for choice of design and range of adjustment often being unclear. Whilst comfort is often reported as improved with an adjustable socket, the rationale behind this is not often discussed, and small study sizes reduce the outcome viability. Many adjustable sockets lack appropriate safety features to limit over or under tightening, which may present a risk of tissue damage or provide inadequate coupling, affecting function and satisfaction. Furthermore, the relationship between design and comfort or function are rarely investigated and remain a significant gap in the literature. Finally, this review highlights the need for improved collaboration between academia and industry, with a strong disconnect observed between commercial devices and published research studies.
17 September 2025 in Medical Engineering & Physics
Upper-limb prostheses users report unsatisfactory 'socket fit', leading to poor outcomes. Previous attempts to measure socket-residuum coupling as a proxy for upper-limb socket fit were limited by their modelling approach (<6-degrees of freedom (DoF) models) and focused on trans-humeral prosthesis users. Prince described a 6-DoF model to track trans-radial (TR) socket-limb coupling, but this required bespoke measurement equipment and was only demonstrated in one intact-limbed participant. Current International Society of Biomechanics (ISB) recommendations for marker-based forearm tracking include ulna styloid markers, therefore being unsuitable for people with TR limb difference. To identify alternative marker frames, ten intact limb participants performed six different movements, nine times each. Displacement of an ulna marker 'cloud' of markers was evaluated, for 18 alternative tracking frames, none of which utilised wrist markers. The optimal frames were a) for a long residuum/full forearm - markers on humeral epicondyles and mid-distal ulna bone (62.5-75 % of a typical ulna), and b) for a shorter residuum - markers on humeral epicondyles and distal ulna bone (25-50 % of a typical ulna). These frames compared favourably to the ISB frame in the point cloud displacement metric. This study provides novel solutions to tracking the ulna bone of people with TR limb difference.