Man Tang

Ms. Man Tang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
MTMan Tang
Man Tang
DCDehua Chen
Dehua Chen
MZMi Zhang
Mi Zhang
FJFeng Jiang
Feng Jiang
YWYu Wang
Yu Wang
The unique double-cantilever beam structure and vibration mode of the tuning fork enable the measuring of fluid density and viscosity synchronously in a decoupling manner. Therefore, it is widely employed in oil and gas development and in petrochemical, food, textile, and other industries. In this paper, quality factors are used to characterize the energy losses of lithium niobate tuning forks when vibrating in a fluid, and the influence parameters, such as length, width, and thickness of the tuning fork arm, etc., of different quality factors are examined with a focus on the viscous quality factor of the fluid. The optimized design of lithium niobate tuning fork dimensions is carried out on this premise, and the analytical solution of the optimal dimension of the lithium niobate tuning fork in the air is obtained. Secondly, the optimal dimension of the lithium niobate tuning fork in fluids is given out by finite element simulation, and the sensitivity of the optimized fork to the viscosity of fluids is investigated. The results show that the optimized tuning fork has a higher quality factor, and thus has a larger parameter measurement range as well as being more sensitive to the change in the fluid density and viscosity. Therefore, the results are of great significance for guiding the preparation and practical application of lithium niobate tuning forks.

26 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FJFeng Jiang
Feng Jiang
DCDehua Chen
Dehua Chen
XHXiao He
Xiao He
YDYuyu Dai
Yuyu Dai
MTMan Tang
Man Tang
MZMi Zhang
Mi Zhang
The use of tuning forks to measure fluid density and viscosity is widely employed in fields such as food, medicine, textiles, automobiles, petrochemicals, and deep drilling. The explicit analytical model based on the Euler–Bernoulli cantilever-beam theory for the relationship between tuning-fork resonance characteristics and the density and viscosity of fluid is only applicable to the situation where the fluid viscous effect is very small. In this paper, the finite element method is used to simulate the influence of large variations in fluid density and viscosity on the resonance characteristic parameters (resonant frequency and quality factor) of the tuning fork. The numerical simulation results are compared with the analytical analysis results and experimental measurement results. Then, the sensitivity of tuning-fork resonance characteristic parameters to fluid density and viscosity is studied. The results show that compared with the analytical results, the numerical simulation results have a higher degree of agreement with the experimental measurement results. The relative difference in resonant frequency is less than 2%, and the relative difference in quality factor is less than 4%. This indicates that the finite element method includes the influence of fluid viscosity on tuning-fork resonance parameters, which is more in line with the actual conditions than the analytical model. Simulating and analyzing the sensitivity of the tuning fork to fluid density and viscosity by the finite element method, it is possible to consider the situation where fluid density and viscosity vary over a large range. Compared with experimental measurements, this method has higher efficiency and can significantly save time and economic costs. This study can overcome the limitation of existing explicit analytical models, which are only applicable when the viscous effects of the fluid are very small. It enables a more accurate simulation of the coupling vibration between tuning forks and fluids, thereby providing theoretical references for further optimizing tuning-fork structural parameters to enhance the accuracy of measuring fluid characteristic parameters.

15 May 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
FJFeng Jiang
Feng Jiang
DCDehua Chen
Dehua Chen
XHXiao He
Xiao He
YDYuyu Dai
Yuyu Dai
MTMan Tang
Man Tang
MZMi Zhang
Mi Zhang
The use of tuning forks to measure fluid density and viscosity is widely employed in fields such as food, medicine, textiles, automobiles, petrochemicals, and deep drilling. The explicit analytical model based on Euler-Bernoulli cantilever beam theory for the relationship between tuning fork resonance characteristics and the density and viscosity of fluid is only applicable to the situation where the fluid viscous effect is very small. In this paper, the finite element method is used to simulate the influence of large variations in fluid density and viscosity on the resonance characteristic parameters (resonant frequency and quality factor) of the tuning fork. The numerical simulation results are compared with the analytical analysis results and experimental measurement results. Then, the sensitivity of tuning fork resonance characteristic parameters to fluid density and viscosity is studied. The results show that compared with the analytical results, the numerical simulation results have a higher degree of agreement with the experimental measurement results. The relative difference in resonant frequency is less than 2%, and the relative difference in quality factor is less than 4%. This indicates that the finite element method includes the influence of fluid viscosity on tuning fork resonance parameters, which is more in line with the actual conditions than the analytical model. Simulating and analyzing the sensitivity of the tuning fork to fluid density and viscosity by the finite element method, it is possible to consider the situation where fluid density and viscosity vary over a large range. Compared with experimental measurements, this method has higher efficiency and can significantly save time and economic costs. This study can overcome the limitation of existing explicit analytical models, which are only applicable when the viscous effects of the fluid are very small. It enables a more accurate simulation of the coupling vibration between tuning forks and fluids, thereby providing theoretical references for further optimizing tuning fork structural parameters to enhance the accuracy of measuring fluid characteristic parameters.