OBJECTIVES: Delayed cerebral ischemia (DCI) is a major driver of morbidity after aneurysmal subarachnoid hemorrhage (aSAH). Quantitative pupillometry has been shown to be of prognostic value after acute neurological injury. However, the evidence for the use of pupillometric features for the detection of DCI has been conflicting. The aim of this study was to investigate the prognostic value of frequent pupillometric monitoring for DCI detection. DESIGN: Observational cohort study from a prospective aSAH registry. SETTING: Tertiary referral center. PATIENTS: Adult patients with confirmed aSAH admitted to the ICU between March 2019 and December 2023. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: One hundred fourteen patients were included, of which 31 (27.2%) suffered from DCI. All patients underwent frequent pupillometry (every 3 hr). We determined the absolute value of the neurological pupil index (NPi) and constriction velocity (CV), and their value normalized to the maximal recorded value between the admission and the pupillometry measure to account for personalized baselines. The association between pupillometry values and the occurrence of DCI within 6–24 hours was investigated. Normalized CV had the best discriminative performance to identify DCI within 8 hours, with an area under the receiver operating characteristic curve of 0.82 (95% CI, 0.69–0.91). NPi, as well as non-normalized metrics, were not significantly associated with DCI. CONCLUSIONS: Normalized CV has a clinically and statistically significant association with the occurrence of DCI after aSAH. Frequent quantitative pupillometry could improve the multimodal monitoring of patients after aSAH with the goal of improving the identification of patients likely to benefit from therapeutic interventions.
A laryngeal mask is one of the most widely used airway management devices. The SingularityTM Air is a second-generation laryngeal mask whose shaft angle can be adjusted after insertion. Since the device’s performance has been assessed on mannequins only, this study aimed to evaluate SingularityTM Air’s effectiveness in the clinical setting. The prospective single-center cohort study included 100 adults undergoing elective surgery under general anesthesia and suitable for airway securing with a laryngeal mask. The primary endpoint was the oropharyngeal leak pressure, and the secondary endpoints were the ease of insertion and the patient’s comfort. Laryngeal mask insertion was successful in 97%, and mechanical ventilation was possible in 96% of patients. After insertion, the median (IQR) oropharyngeal leak pressure was 25 (18–25) cm H2O, which remained stable at 25 (25–25) cm H2O after 20 min. The median (IQR) time for successful manual bag ventilation was 42 (34–50) seconds. Nineteen patients complained of side effects (e.g., sore throat, difficulty swallowing), but none persisted. The SingularityTM Air performed well in a clinical setting, and its oropharyngeal leak pressure was comparable to that of other masks reported in the literature. The time for successful manual ventilation was slightly longer, and patients reported more temporary side effects.