Faisal Alrehily

Dr. Faisal Alrehily


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2023 in Saudi Medical Journal
Verified
Journal Article
Open access
PDF file
FAFaisal Alrehily
Faisal Alrehily
KAKhalid S. Alqahtani
Khalid S. Alqahtani
MAMarwan H. Aljohani
Marwan H. Aljohani
NANawaf S. Alharbi
Nawaf S. Alharbi
RAReyan M. Alharbi
Reyan M. Alharbi
FAFahad H. Alhazmi
Fahad H. Alhazmi
Objectives: To establish local DRL (LDRL) for computed tomography (CT) examinations based on size-specific dose estimates (SSDEs), which consider patient size. The concept of diagnostic reference level (DRL) was introduced to limit patient exposure to unnecessary radiation. However, traditional DRL values do not consider patient size. Methods: Following institutional committee approval, data were collected from CT examinations of adult patients at Madinah General Hospital, Al Madinah Al Munawwarah, Saudi Arabia from January to March 2023. The SSDE was calculated for each patient using the effective diameter (Deff). Results: The LDRLs of the brain, cervical spine, chest, thoracic spine and kidneys, ureters, and bladder (KUB) examinations were 118 mGy, 12 mGy, 8 mGy, 17 mGy, and 7 mGy, respectively. A strong correlation was observed between SSDEs and the volume computed tomography dose index (CTDIvol) for all examinations except chest scans (p<0.05). Size-specific dose estimates were higher than the CTDIvol, with a greater difference for patients with smaller Deff (p<0.05). Conclusion: The established LDRL was within the international DRL. The use of SSDE has the potential to provide more accurate and relevant data for radiation safety practices; however, widespread adoption of SSDE in new CT scanners is necessary for promoting consistency and standardization methodologies.

19 September 2022 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
FAFaisal Alrehily
Faisal Alrehily
A systematic search was conducted to explore the literature on the existing diagnostic reference level (DRL) of radiographic and computed tomography (CT) examinations in Saudi Arabia. The search was performed using Web of Science, Scopus and EBSCO. The search identified 19 studies that reported DRL values for radiographic and CT examinations in Saudi Arabia. Six of those studies reported DRL values for projection radiography, and the remaining studies reported DRL values for CT examinations (n = 13). The entrance surface dose, volume CT dose index (CTDIvol) and dose-length product (DLP) were the most common methods used for establishing the DRLs. Variations were observed in the Saudi DRL values, and this is consistent with the DRL values reported in the literature. Educating and training radiographers to better understand dose minimizing techniques may result in lower patient doses and lower variances in DRL values.

12 August 2024 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
FAFaisal Alrehily
Faisal Alrehily
Calculating size-specific dose estimates (SSDEs) requires measurement of the patient’s anteroposterior (AP) and lateral thickness based on computed tomography (CT) images. However, these measurements can be subject to variation due to inter-observer and intra-observer differences. This study aimed to investigate the impact of these variations on the accuracy of the calculated SSDE. Four radiographers with 1–10 years of experience were invited to measure the AP and lateral thickness on 30 chest, abdomen, and pelvic CT images. The images were sourced from an internet-based database and anonymized for analysis. The observers were trained to perform the measurements using MicroDicom software and asked to repeat the measurements 1 week later. The study was approved by the institutional review board at Taibah University, and written informed consent was obtained from the observers. Statistical analyses were performed using Python libraries Pingouin (version 0.5.3), Seaborn (version 0.12.2), and Matplotlib (version 3.7.1). The study revealed excellent inter-observer agreement for the calculated effective diameter and AP thickness measurements, with Intraclass correlation coefficients (ICC) values of 0.95 and 0.96, respectively. The agreement for lateral thickness measurements was lower, with an ICC value of 0.89. The second round of measurements yielded nearly the same levels of inter-observer agreement, with ICC values of 0.97 for the effective diameter, 1.0 for AP thickness, and 0.88 for lateral thickness. When the consistency of the observer was examined, excellent consistency was found for the calculated effective diameter, with ICC values ranging from 0.91 to 1.0 for all observers. This was observed despite the lower consistency in the lateral thickness measurements, which had ICC values ranging from 0.78 to 1.0. The study’s findings suggest that the measurements required for calculating SSDEs are robust to inter-observer and intra-observer differences. This is important for the clinical use of SSDEs to set diagnostic reference levels for CT scans.

27 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KAKhalid M Aloufi
Khalid M Aloufi
FAFahad H. Alhazmi
Fahad H. Alhazmi
FAFaisal Alrehily
Faisal Alrehily
NANadia S Alraddadi
Nadia S Alraddadi
AAAHMED SALEM ALHARBI
AHMED SALEM ALHARBI
FHFai H. Hadi
Fai H. Hadi
This study aims to assess effective radiation doses (EDs) for pediatric computed tomography (CT) procedures in Madinah (single hospital), Saudi Arabia, and propose diagnostic reference levels (DRLs) for these procedures. This retrospective study collected data from 600 pediatric patients who underwent five CT procedures. The data were categorized by the type of CT procedure and the age of the patients. EDs and proposed DRLs for the pediatric CT procedures were computed. The highest EDs were found for abdominal (6.3 mSv) and head (4.8 mSv) CT procedures in pediatric patients aged <1 year. DRLs of the CTDIvol and DLP for abdominal and head CT procedures in pediatric patients aged <1 year were 4.2 mGy, 94 mGy.cm and 25 mGy, 414 mGy.cm, respectively. Chest EDs had the lowest EDs among all pediatric CT procedures, with EDs of 1.93, 1.51, 1.91, and 2.05 mSv in patients aged <1, 1 ≤ to < 5, 5 ≤ to < 10, and 10 ≤ to ≤ 15 years, respectively. It can be concluded that optimization is required for abdominal and head CT procedures in pediatric patients aged <1 year. Frequent updates on ED and DRL calculations will help monitor radiation doses and minimize radiation risks for patients undergoing these procedures.

19 December 2024 in Diseases
Verified
Journal Article
Open access
PDF file
SASultan Abdulwadoud Alshoabi
Sultan Abdulwadoud Alshoabi
Abdulkhaleq Ayedh BinnuhaidAbdulkhaleq Ayedh Binnuhaid
Abdulkhaleq Ayedh Binnuhaid
HMHalah Fuad Muslem
Halah Fuad Muslem
AHAbdullgabbar Hamid
Abdullgabbar Hamid
FAFahad H. Alhazmi
Fahad H. Alhazmi
AOAwatif M Omer
Awatif M Omer
Background: Obstructive jaundice is a common health challenge in daily clinical practice caused by a heterogeneous group of benign and malignant conditions in or around extrahepatic bile ducts. This study aimed to investigate the causes of obstructive jaundice, analyze the age and sex distribution, and report the locations of obstruction. Methods: This was a retrospective study of electronic records of patients diagnosed with obstructive jaundice in the Hadhramout region in Yemen. Results: This study analyzed the data of 303 patients (mean age: 57 ± 17.99 years; range: 18–95 years); 60.40% (n = 183) were female, and 39.60% (n = 120) were male. The highest prevalence was found in middle-aged adults (n = 112, 36.96%), followed by the old (n = 101, 33.33%). Common bile duct (CBD) stones were the most common cause of obstructive jaundice (n = 175, 57.8%), followed by CBD stricture (n = 58, 19.1%), carcinoma of the head of the pancreas (n = 35, 11.6%), cholangiocarcinoma (n = 21, 6.9%), and external compression of the CBD (n = 2, 0.7%). CBD stones, cholangiocarcinoma, and ampulla of Vater masses were more prevalent in females (30.9%, 3.8%, and 2.2%, respectively) than in males (25.8%, 2.9%, and 1.7%, respectively). In contrast, CBD stricture and carcinoma of the pancreas were more frequent in males, occurring in 12.1% and 7.1% of male patients, respectively, compared to 7.9% and 4.9% in female patients. The primary obstruction site was the CBD (n = 254, 83.8%), followed by the head of the pancreas (n = 30, 9.9%), and the ampulla of Vater (n = 13, 4.3%). Conclusions: Obstructive jaundice predominantly affects middle-aged adults followed by the old-aged patients predominantly in females. The most common cause of obstructive jaundice was CBD stones, followed by CBD stricture, while carcinoma of the head of the pancreas was the most common malignant cause, followed by cholangiocarcinoma. Distal CBD is the most common anatomical location of obstructive jaundice.

20 September 2024 in PeerJ
Verified
Journal Article
Open access
PDF file
FAFaisal Alrehily
Faisal Alrehily
WAWalaa Alsharif
Walaa Alsharif
YAYasser Aloufi
Yasser Aloufi
AAAmmar Alsaedi
Ammar Alsaedi
MAMarwan Aljohani
Marwan Aljohani
AQAbdulaziz Qurashi
Abdulaziz Qurashi
Introduction: Radiography is a crucial healthcare specialty that requires ongoing research to advance imaging technologies and techniques. Despite this, radiographers are faced with obstacles such as time constraints, lack of resources, and the need for training on new technologies, which can discourage their research involvement. This study aims to provide a more representative understanding of the radiography research culture in Saudi Arabia, building upon previous studies. Methods: Following the approval of an ethics committee at Taibah University (2024/173/302 DRD), a cross-sectional survey was conducted from January to March 2024 among registered radiographers in Saudi Arabia. An online questionnaire was distributed via social media platforms using a snowball sampling strategy to reach a diverse group of radiographers across different regions and institutions. Participants provided informed consent before completing the questionnaire. The questionnaire, originally in English, was translated into Arabic and validated by two bilingual academics. It included sections on demographics, previous research experience, barriers to research involvement, factors encouraging research engagement, and self-assessment of research competencies. Descriptive statistics and Cronbach’s alpha were used to analyze the data. Results: A total of 105 radiographers participated in the study, with 41% having prior research involvement. Among those engaged, the most common activity was data collection (65%), followed by preparation of scientific articles (49%). Challenges such as the lack of a research-focused culture (48%), insufficient awareness of opportunities (36%), and time constraints (34%) were prominent barriers to research participation. Encouraging factors included the need for research training (63%), support from research groups (51%), and allocated research time (50%). Respondents assessed their research skills, with confidence varied across skills, with 50% feeling capable of initiating research and 51% of participating, yet a significant proportion expressed uncertainties, especially in statistical knowledge and research methodology. Conclusion: Most of the surveyed radiographers did not engage in research. However, there is a substantial interest in enhancing research involvement, with training, collaborative groups, and organizational support identified as key factors encouraging participation. The findings suggest that addressing these barriers can foster a more robust research culture, leading to improved diagnostic practices.