BACKGROUND AND PURPOSE: DSC-MR imaging using preload, intermediate (60°) flip angle and postprocessing leakage correction has gained traction as a standard methodology. Simulations suggest that DSC-MR imaging with flip angle = 30° and no preload yields relative CBV practically equivalent to the reference standard. This study tested this hypothesis in vivo. MATERIALS AND METHODS: Eighty-four patients with brain lesions were enrolled in this 3-institution study. Forty-three patients satisfied the inclusion criteria. DSC-MR imaging (3T, single-dose gadobutrol, gradient recalled-echo–EPI, TE = 20–35 ms, TR = 1.2–1.63 seconds) was performed twice for each patient, with flip angle = 30°–35° and no preload (P−), which provided preload (P+) for the subsequent intermediate flip angle = 60°. Normalized relative CBV and standardized relative CBV maps were generated, including postprocessing with contrast agent leakage correction (C+) and without (C−) contrast agent leakage correction. Contrast-enhancing lesion volume, mean relative CBV, and contrast-to-noise ratio obtained with 30°/P−/C−, 30°/P−/C+, and 60°/P+/C− were compared with 60°/P+/C+ using the Lin concordance correlation coefficient and Bland-Altman analysis. Equivalence between the 30°/P−/C+ and 60°/P+/C+ protocols and the temporal SNR for the 30°/P− and 60°/P+ DSC-MR imaging data was also determined. RESULTS: Compared with 60°/P+/C+, 30°/P−/C+ had closest mean standardized relative CBV (P = .61), highest Lin concordance correlation coefficient (0.96), and lowest Bland-Altman bias (μ = 1.89), compared with 30°/P−/C− (P = .02, Lin concordance correlation coefficient = 0.59, μ = 14.6) and 60°/P+/C− (P = .03, Lin concordance correlation coefficient = 0.88, μ = −10.1) with no statistical difference in contrast-to-noise ratios across protocols. The normalized relative CBV and standardized relative CBV were statistically equivalent at the 10% level using either the 30°/P−/C+ or 60°/P+/C+ protocols. Temporal SNR was not significantly different for 30°/P− and 60°/P+ (P = .06). CONCLUSIONS: Tumor relative CBV derived from low–flip angle, no-preload DSC-MR imaging with leakage correction is an attractive single-dose alternative to the higher dose reference standard.
12 March 2020 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Perfusion MR imaging measures of relative CBV can distinguish recurrent tumor from posttreatment radiation effects in high-grade gliomas. Currently, relative CBV measurement requires normalization based on user-defined reference tissues. A recently proposed method of relative CBV standardization eliminates the need for user input. This study compares the predictive performance of relative CBV standardization against relative CBV normalization for quantifying recurrent tumor burden in high-grade gliomas relative to posttreatment radiation effects. MATERIALS AND METHODS: We recruited 38 previously treated patients with high-grade gliomas (World Health Organization grades III or IV) undergoing surgical re-resection for new contrast-enhancing lesions concerning for recurrent tumor versus posttreatment radiation effects. We recovered 112 image-localized biopsies and quantified the percentage of histologic tumor content versus posttreatment radiation effects for each sample. We measured spatially matched normalized and standardized relative CBV metrics (mean, median) and fractional tumor burden for each biopsy. We compared relative CBV performance to predict tumor content, including the Pearson correlation (r), against histologic tumor content (0%–100%) and the receiver operating characteristic area under the curve for predicting high-versus-low tumor content using binary histologic cutoffs (≥50%; ≥80% tumor). RESULTS: Across relative CBV metrics, fractional tumor burden showed the highest correlations with tumor content (0%–100%) for normalized (r = 0.63, P < .001) and standardized (r = 0.66, P < .001) values. With binary cutoffs (ie, ≥50%; ≥80% tumor), predictive accuracies were similar for both standardized and normalized metrics and across relative CBV metrics. Median relative CBV achieved the highest area under the curve (normalized = 0.87, standardized = 0.86) for predicting ≥50% tumor, while fractional tumor burden achieved the highest area under the curve (normalized = 0.77, standardized = 0.80) for predicting ≥80% tumor. CONCLUSIONS: Standardization of relative CBV achieves similar performance compared with normalized relative CBV and offers an important step toward workflow optimization and consensus methodology.
The implementation of clinical 7T MRI presents both opportunities and challenges for advanced medical imaging. This tutorial provides practical considerations and experiences with 7T MRI in clinical settings. We first explore the history and evolution of MRI technology, highlighting the benefits of increased signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and susceptibility at 7T. Technical challenges such as increased susceptibility artifacts and RF inhomogeneity are also discussed, along with innovative adaptations. This review also discusses hardware and software considerations, including new parallel transmission head coils and advanced image processing techniques to optimize image quality. Safety considerations, such as managing tissue heating and susceptibility to artifacts, are also discussed. Additionally, clinical applications of 7T MRI are examined, focusing on neurological conditions such as epilepsy, multiple sclerosis, and vascular imaging. Emerging trends in the use of 7T MRI for spectroscopy, perfusion imaging, and multinuclear imaging are explored, with insights into the future of ultra-high-field MRI in clinical practice. This review aims to provide clinicians, technologists, and researchers with a roadmap for successfully implementing 7T MRI in both research and clinical environments.
Hippocampal segmentation is essential in neuroimaging for evaluating conditions like Alzheimer’s dementia and mesial temporal sclerosis, where small volume changes can significantly impact normative percentiles. However, inaccurate segmentation is common due to the inclusion of non-hippocampal structures such as choroid plexus and cerebrospinal fluid (CSF), leading to volumetric overestimation and confounding of functional analyses. Current methods of assessment largely rely on virtual or manual ground truth labels, which can fail to capture these inaccuracies. To address this shortcoming, this study introduces a more direct voxel intensity-based method of segmentation assessment. Using paired precontrast and postcontrast T1-weighted MRIs, hippocampal segmentations were refined by adding marginal gray matter and removing marginal CSF and enhancement to determine a total required correction volume. Six segmentation algorithms—e2dhipseg, HippMapp3r, hippodeep, AssemblyNet, FastSurfer, and QuickNat—were implemented and compared. HippMapp3r and e2dhipseg, followed closely by hippodeep, exhibited the least total correction volumes, indicating superior accuracy. Dedicated hippocampal segmentation algorithms outperformed whole-brain methods.