An AC excitation power supply will produce a series of harmonic currents in motors compared to the conventional power supply, increase the time harmonic component, and then generate a harmonic magnetic field; harmonics will cause motor vibrations and noise in the motor and will produce a corresponding additional loss, increasing the motor temperature rise; these key technical problems need to be solved in domestic pumped storage AC excitation motor engineering applications. Herein, the no-load loss characteristic test of a 3 MW alternating current excited motor was mainly carried out using a test prototype of the 3 MW alternating current excitation motor. Further, with the aid of the finite element method, the numerical study of the no-load loss characteristics of a 3 MW alternating current excited motor was performed. The relationship between the key factors such as the no-load characteristics, no-load loss characteristics, and constant loss and voltage per unit value is analyzed, and the variation law of the no-load core loss of motors under different loads is explored. The results demonstrate that, under no-load conditions, when the applied voltage was less than the rated voltage, the voltage was proportional to the current. When the applied voltage was more significant than the rated voltage, the current increased as the voltage increased, but the relationship between the two was no longer proportional. The constant loss of the motor maintained a linear relationship with the square of the unit value of the voltage scale. When the square of the unit value of the voltage scale was zero, the loss was equivalent to the wind friction loss under no load. The core loss increased with the increase in load, and the greater the load, the faster the increase rate of the motor iron loss. The comparison deviation between the test and simulation results was less than 10%. The simulation and experimental results verified the effectiveness of finite element modeling and the finite element calculation method.
An uneven electric field during the operation of an electrode boiler will lead to the emergence of a high field strength area and low field strength area in the furnace, which will endanger the safe and reliable operation and heating efficiency of the electrode boiler. A numerical study of three-dimensional transient electric field distribution characteristics in a 10 kV high-voltage electrode boiler was carried out. The distribution characteristics of the global electric field of the electrode boiler under the nominal voltage of 10 kV were studied, and the distribution law of the electric field of the electrode boiler under poor power quality, such as different bus voltage and three-phase voltage imbalance, was explored. The results show that the electric field distribution characteristics of the three-phase transient are more obvious in the section closer to the electrode disc, and the electric field distribution is the most uniform in the section that is 1.4 m away from the furnace water. In the case of poor power quality, such as different bus voltage and three-phase voltage imbalance, the points of the maximum electric field intensity of the four surfaces change periodically with time, and the greater the bus voltage fluctuation, the more severe the impact on the transient electric field. The three-phase voltage imbalance will shift the peak value of the electric field intensity. The decrease or offset of electric field intensity in the electrode boiler caused by poor power quality will directly affect its heating efficiency. The electric field simulation results have a specific reference value for improving the internal electric field distribution and on-site operation and maintenance of the electrode boiler.