A wireless power transfer system using an inductive link has been demonstrated for implantable sensor applications. The system is composed of two primary blocks: an inductive power transfer unit and a backward data communication unit. The inductive link performs two functions: coupling the required power from a wireless power supply system enabling battery-less, long-term implant operation and providing a backward data transmission path. The backward data communication unit transmits the data to an outside reader using FSK modulation scheme via the inductive link. To demonstrate the operation of the inductive link, a board-level design has been implemented with high link efficiency. Test results from a fabricated sensor system, composed of a hybrid implementation of custom-integrated circuits and board-level discrete components, are presented demonstrating power transmission of 125 mW with a 12.5% power link transmission efficiency. Simultaneous backward data communication involving a digital pulse rate of up to 10 kbps was also observed.
12 April 2010 in IEEE Transactions on Biomedical Circuits and Systems
Low voltage and low power are two key requirements for on-chip realization of wireless power and data telemetry for applications in biomedical sensor instrumentation. Batteryless operation and wireless telemetry facilitate robust, reliable, and longer lifetime of the implant unit. As an ongoing research work, this paper demonstrates a low-power low-voltage sensor readout circuit which could be easily powered up with an inductive link. This paper presents two versions of readout circuits that have been designed and fabricated in bulk complementary metal-oxide semiconductor (CMOS) processes. Either version can detect a sensor current in the range of 0.2 μA to 2 μA and generate square-wave data signal whose frequency is proportional to the sensor current. The first version of the circuit is fabricated in a 0.35-μ m CMOS process and it can generate an amplitude-shift-keying (ASK) signal while consuming 400 μ W of power with a 1.5-V power supply. Measurement results indicate that the ASK chip generates 76 Hz to 500 Hz frequency of a square-wave data signal for the specified sensor current range. The second version of the readout circuit is fabricated in a 0.5-μ m CMOS process and produces a frequency-shift-keying (FSK) signal while consuming 1.675 mW of power with a 2.5-V power supply. The generated data frequency from the FSK chip is 1 kHz and 9 kHz for the lowest and the highest sensor currents, respectively. Measurement results confirm the functionalities of both prototype schemes. The prototype circuit has potential applications in the monitoring of blood glucose level, lactate in the bloodstream, and pH or oxygen in a physiological system/environment.
Thin, flexible, robust capacitive pressure sensors have been the subject of research in many fields where axial strain sensing with high spatial resolution and pressure resolution is desirable for small loads, such as tactile robotics and biomechanics. Simple capacitive pressure sensors have been designed and implemented on flexible substrates in general agreement with performance predicted by an analytical model. Two designs are demonstrated for comparison. The first design uses standard flex circuit technology, and the second design uses photolithography techniques to fabricate capacitive sensors with higher spatial and higher pressure resolution. Sensor arrays of varying sensor size and spacing are tested with applied loads from 0 to 1 MPa. Pressure resolution and linearity of the sensors are significantly improved with the miniaturized, custom fabricated sensor array compared to standard flexible circuit technology.
This paper has presented a low-power capacitance read-out circuit which could be used for biomedical sensor applications. The differential structure of the system eliminates even order distortion. The entire system manifests two current sense amplifiers, two diode rectifiers and one instrumentation amplifier. The circuit has been realized using TSMC 0.35 mum bulk CMOS process. The circuit operates with a 3 V power supply and consumes 5.384 mW of power. Simulation results show that the circuit has a sensitivity of 1.32 mV for 1 fF capacitance change. Measurement results for different capacitance variations demonstrate a change of 10.8 mV for 8.8 fF variation.
25 July 2022 in IEEE Journal on Flexible Electronics
Inkjet printing circuits onto thin, flexible substrates is a newly explored field with respect to the transistor; a critical element needed to form logic gates and high-level active circuitry. The traditional approach is to achieve comparable performance to MOSFETs or BJTs. However, the introduction of neuromorphics, spintronics, memristors, chaotic materials and limitations of transistor sizes have incited a shift toward alternative computing schemes that do not behave as standard transistors. This work explores a minimal fabrication, low-cost, non-linear, current-controlled Graphene Inkjet Printed Artificial Neuron that performs the computing of a recurrent neural network when multiple units are coupled. An activation function (inverse hyperbolic sine) is fit to the electrical curve of the current-controlled Graphene element with R-Squared of 0.997. The standard neuron is replaced with the modeled one in the Echo State Network for training on the MNIST benchmark dataset for handwritten digit classification. Testing performance of the simulated inkjet printed neuron reached 88.1% classification, and was marginally better than the sigmoid and hyperbolic tangent functions. This work demonstrates a minimal-fabrication alternative computing element functioning as a simulated artificial neuron in the Echo State Network. Benefits include low-cost fabrication, high power-efficiency, physically flexible edge computing, and development into many applications within telehealth, infrastructure, military, sports, etc. This work supports efforts toward a printable, cost-effective, flexible, and scalable physical machine learning system.