11 August 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
CAChristos Antypas
Christos Antypas
EPEvaggelos Pantelis
Evaggelos Pantelis
The aim of the current work was to present the performance evaluation procedures implemented at our department for the commissioning of a G4 CyberKnife system. This system consists of a robotic manipulator, a target-locating system and a lightweight 6-MV linac. Individual quality assurance procedures were performed for each of the CyberKnife subsystems. The system was checked for the mechanical accuracy of its robotic manipulator. The performance of the target-locating system was evaluated in terms of mechanical accuracy of both cameras' alignment and quality assurance tests of the x-ray generators and the flat-panel detectors. The traditional linac 6-MV beam characteristics and beam output parameters were also measured. Results revealed a manipulator mechanical mean accuracy of approximately 0.1 mm, with individual maximum position uncertainties less than 0.25 mm. The target-locating system mechanical accuracy was found within the acceptance limits. For the most clinically used parameters in the CyberKnife practice, e.g. 100-120 kV and 50-200 ms, kV and exposure time accuracy error were measured as less than 2%, while the precision error of the kV was determined as less than 1%. The acquired images of the ETR grid pattern revealed no geometrical distortion while the critical frequency f50 values for cameras A and B were calculated as 1.5 lp mm(-1) and 1.4 lp mm(-1), respectively. Dose placement measurements were performed in a head and neck phantom. Results revealed sub-millimeter beam delivery precision whereas the total clinical accuracy of the system was measured equal to 0.44 +/- 0.12 mm, 0.29 +/- 0.10 mm and 0.53 +/- 0.16 mm for the skull, fiducial and Xsight spine tracking methods, respectively. The results of this work certify the G4 CyberKnife SRS system capable of delivering high dose distributions with sub-millimeter accuracy and precision to intracranial and extracranial lesions. Moreover, total clinical accuracy of the investigated G4 system was found to be improved for the skull and fiducial tracking methods and was comparable for Xsight spine tracking method compared with the earlier generation of the instrument.


14 May 2008 in Medical Physics
Verified
Journal Article
Closed access
EPEvaggelos Pantelis
Evaggelos Pantelis
CAChristos Antypas
Christos Antypas
LPL. Petrokokkinos
L. Petrokokkinos
PKP. Karaiskos
P. Karaiskos
PPP. Papagiannis
P. Papagiannis
ISI. Seimenis
I. Seimenis

20 January 2010 in Medical Physics
Verified
Journal Article
Closed access
KZK. Zourari
K. Zourari
EPEvaggelos Pantelis
Evaggelos Pantelis
AMArgyris Moutsatsos
Argyris Moutsatsos
LPL. Petrokokkinos
L. Petrokokkinos
PKP. Karaiskos
P. Karaiskos
PPP. Papagiannis
P. Papagiannis

1 September 2014 in British Journal of Radiology
Verified
Journal Article
Closed access
PPP Papagiannis
P Papagiannis
EPEvaggelos Pantelis
Evaggelos Pantelis
PKP Karaiskos
P Karaiskos
Following literature contributions delineating the deficiencies introduced by the approximations of conventional brachytherapy dosimetry, different model-based dosimetry algorithms have been incorporated into commercial systems for (192)Ir brachytherapy treatment planning. The calculation settings of these algorithms are pre-configured according to criteria established by their developers for optimizing computation speed vs accuracy. Their clinical use is hence straightforward. A basic understanding of these algorithms and their limitations is essential, however, for commissioning; detecting differences from conventional algorithms; explaining their origin; assessing their impact; and maintaining global uniformity of clinical practice.

1 September 2010 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
EPEvaggelos Pantelis
Evaggelos Pantelis
NPNikolaos Papadakis
Nikolaos Papadakis
KVKosmas Verigos
Kosmas Verigos
ISIrene Stathochristopoulou
Irene Stathochristopoulou
CAChristos Antypas
Christos Antypas
NSNikolaos Salvaras
Nikolaos Salvaras