Merve Eksioglu

Dr. Merve Eksioglu

Emergency, Fatih Sultan Mehmet Eğitim Ve Araştırma Hastanesi, Istanbul, İstanbul, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2025 in International Journal of General Medicine
Verified
Journal Article
Open access
PDF file
MEMerve Eksioglu
Merve Eksioglu
BKBurcu Azapoglu Kaymak
Burcu Azapoglu Kaymak
EAEbru Unal Akoglu
Ebru Unal Akoglu
SASelman Akyıldız
Selman Akyıldız
RSRamazan Sivil
Ramazan Sivil
TOTuba Cimilli Ozturk
Tuba Cimilli Ozturk
Purpose: This study aimed to assess the prognostic accuracy of the Glasgow Prognostic Score (GPS), modified Glasgow Prognostic Score (mGPS), and C-reactive protein/albumin ratio (CAR) in predicting 30-day mortality and intensive care unit (ICU) admission compared with the Pneumonia Severity Index (PSI) and CURB-65 in older adults with community-acquired pneumonia (CAP). Patients and Methods: This retrospective, single-center cohort study was conducted in a tertiary emergency department. Patients aged ≥ 65 years with CAP were included. Exclusion criteria were hospital- or ventilator-associated pneumonia, pneumonia mimics, and immunocompromised status. GPS and mGPS were calculated using CRP > 10 mg/L and albumin < 35 g/L. ROC and logistic regression analyses were performed. Results: A total of 349 patients (mean age: 77.96 ± 8.42 years; 52.7% men) were included. The 30-day mortality and ICU admission rates were 19.5% and 27.2%, respectively. For predicting mortality, the GPS showed an AUC of 0.753 (95% CI: 0.690– 0.816), sensitivity of 75.0%, specificity of 73.3%, PPV of 43.9%, and NPV of 92.4%. mGPS had an AUC of 0.747 (95% CI: 0.679– 0.814), sensitivity 77.9%, specificity 73.3%, PPV 45.2%, and NPV 93.2%. The CAR yielded an AUC of 0.677 (95% CI: 0.604– 0.751), sensitivity of 82.4%, specificity of 45.6%, PPV of 29.5%, and NPV of 91.4%. For ICU admission, the AUCs were 0.770 (GPS), 0.757 (mGPS), and 0.676 (CAR). The PSI demonstrated the highest predictive accuracy (AUC: 0.884 for mortality, 0.919 for ICU admission), followed by CURB-65 (AUC: 0.848 and 0.879, respectively). Independent predictors of 30-day mortality included acute confusion, lower PaO2/FiO2 ratio, low systolic blood pressure, reduced hemoglobin levels, and Alzheimer’s disease or dementia. Conclusion: The PSI and CURB-65 demonstrated superior prognostic accuracy. GPS and mGPS showed moderate performance, whereas CAR exhibited the lowest overall discriminative ability for both outcomes.

21 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MEMerve Eksioglu
Merve Eksioglu
BKBurcu Azapoğlu Kaymak
Burcu Azapoğlu Kaymak
AEAtilla Halil Elhan
Atilla Halil Elhan
TÖTuba Cimilli Öztürk
Tuba Cimilli Öztürk
Background/Objectives: This study aimed to compare the diagnostic accuracy of the Wells and Geneva scores using a 500 ng/mL D-dimer cutoff, as well as the age-adjusted D-dimer (AADD), YEARS, and pulmonary embolism graduated D-dimer (PEGeD) algorithms, in patients with and without COVID-19. Various D-dimer cutoffs were also evaluated. Methods: This retrospective study included emergency department patients who underwent computed tomography pulmonary angiography (CTPA) for suspected pulmonary embolism (PE). The diagnostic performances of clinical prediction algorithms were compared between COVID-19-positive and -negative groups. Results: We analyzed data from 1423 patients; the PE and COVID-19 positivity rates were 7.3% and 69.9%, respectively. In COVID-19-positive patients, the Wells score with a 500 ng/mL D-dimer cutoff demonstrated 97.22% sensitivity (95% CI: 80.53–100.00) and 4.99% specificity (95% CI: 3.58–6.39). Using AADD raised the specificity to 7.81% (95% CI: 6.08–9.54) while maintaining 97.22% sensitivity (95% CI: 93.43–100.00); similar findings were observed with the Geneva score. The YEARS algorithm had 86.11% sensitivity (95% CI: 78.12–94.10) and 32.75% specificity (95% CI: 29.73–35.78), whereas the PEGeD algorithm showed 86.11% sensitivity (95% CI: 78.12–94.10) and 34.06% specificity (95% CI: 31.00–37.12). Both algorithms demonstrated slightly improved specificity and accuracy in COVID-19-positive patients. Conclusions: The YEARS and PEGeD algorithms showed slight improvements in specificity and accuracy among COVID-19-positive patients. The Wells and Geneva scores maintained higher sensitivity but lower specificity across groups. Adjusting the D-dimer cutoffs increased the specificity but increased the risk of missed diagnoses. Overall, COVID-19 had a minimal impact on PE diagnostic algorithm performances.

15 September 2023 in Prehospital and Disaster Medicine
Verified
Journal Article
Closed access
PDF file
MEMerve Eksioglu
Merve Eksioglu
BKBurcu Azapoğlu Kaymak
Burcu Azapoğlu Kaymak
Introduction: Handheld ultrasound (HHU) devices have gained prominence in emergency care settings and post-graduate training, but their application in the diagnosis of pediatric fractures remains under-explored. The aim of this study is to evaluate the effectiveness and accuracy of an HHU device for diagnosing pediatric forearm fractures using a simulation model.Methods: The materials for the basic pediatric fracture model include turkey bones soaked in white vinegar to make them pliable, food-grade gelatine, and plastic containers. Ultrasound analysis of the models was done with an HHU device, Sonosite İViz US (FUJIFILM Sonosite, Inc.; Bothell, Washington USA). Four different fracture patterns (transverse fracture, oblique fracture, greenstick fracture, and a torus fracture) and one model without fracture were used in this study. Twenty-six Emergency Medicine residents sonographically evaluated different bone models in order to define the presence and absence of fracture and the fracture subtype. The participants’ ability to obtain adequate images and the time taken to create and recognize the images were evaluated and recorded. After the sonographic examination, the residents were also asked for their opinion on the model as a teaching tool.Results: All participants (100%) recognized the normal bone model and the fracture, regardless of the fracture type. The consistency analysis between the practitioners indicated a substantial agreement (weighted kappa value of 0.707). The duration to identify the target pathology in fracture models was significantly longer for the greenstick fracture (78.57 [SD = 30.45] seconds) model compared to other models. The majority of participants (92.3%) agreed that the model used would be a useful teaching tool for learning ultrasound diagnosis of pediatric forearm fractures.Conclusions: All participants successfully identified both the normal bone model and the presence of fractures, irrespective of the fracture type. Significantly, the identification of the greenstick fracture took longer compared to other fracture types. Moreover, the majority of participants acknowledged the model’s utility as a teaching tool for learning ultrasound diagnosis of pediatric forearm fractures.

17 May 2024 in Prehospital and Disaster Medicine
Verified
Journal Article
Closed access
PDF file
BKBurcu Azapoğlu Kaymak
Burcu Azapoğlu Kaymak
MEMerve Eksioglu
Merve Eksioglu
Introduction: Handheld ultrasound (US) devices have become increasingly popular since the early 2000s due to their portability and affordability compared to conventional devices. The Rapid Ultrasonography for Shock and Hypotension (RUSH) protocol, introduced in 2009, has shown promising accuracy rates when performed with handheld devices. However, there are limited data on the accuracy of such examinations performed in a moving ambulance. This study aimed to assess the feasibility and accuracy of the RUSH protocol performed by paramedics using handheld US devices in a moving ambulance.Objectives: The study aimed to examine the performability of the RUSH protocol with handheld US devices in a moving ambulance and to evaluate the accuracy of diagnostic views obtained within an appropriate time frame.Methods: A prospective study was conducted with paramedics who underwent theoretical and practical training in the RUSH protocol. The participants performed the protocol using a handheld US device in both stationary and moving ambulances. Various cardiac and abdominal views were obtained and evaluated for accuracy. The duration of the protocol performance was recorded for each participant.Results: Nine paramedics completed the study, with 18 performances each in both stationary and moving ambulance groups. The accuracy of diagnostic views obtained during the RUSH protocol did not significantly differ between the stationary and moving groups. However, the duration of protocol performance was significantly shorter in the moving group compared to the stationary group.Conclusion: Paramedics demonstrated the ability to perform the RUSH protocol effectively using handheld US devices in both stationary and moving ambulances following standard theoretical and practical training. The findings suggest that ambulance movement does not significantly affect the accuracy of diagnostic views obtained during the protocol. Further studies with larger sample sizes are warranted to validate these findings and explore the potential benefits of prehospital US in dynamic environments.

29 October 2025 in Heart & Lung
Verified
Journal Article
Closed access
YSYunus Emre Sagmal
Yunus Emre Sagmal
MEMerve Eksioglu
Merve Eksioglu
BKBurcu Azapoğlu Kaymak
Burcu Azapoğlu Kaymak
TÖTuba Cimilli Öztürk
Tuba Cimilli Öztürk

18 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MEMerve Eksioglu
Merve Eksioglu
BKBurcu Azapoğlu Kaymak
Burcu Azapoğlu Kaymak
AEAtilla Halil Elhan
Atilla Halil Elhan
TÖTuba Cimilli Öztürk
Tuba Cimilli Öztürk
Background/Objectives: This study aimed to compare the diagnostic accuracy of the Wells and Geneva scores, used with a 500 ng/mL D-dimer cutoff, along with the age-adjusted D-dimer (AADD), YEARS, and PEGeD algorithms in patients with and without COVID-19. The performance of various D-dimer thresholds was also evaluated. Methods: This retrospective study included patients who presented to the emergency department and underwent computed tomography pulmonary angiography (CTPA) for suspected pulmonary embolism (PE). The diagnostic performance of clinical prediction algorithms was compared between two groups. Results: We analyzed data from 1423 patients; PE diagnosis and COVID-19 positivity rates were 7.3% and 69.9%, respectively. In patients with COVID-19, the Wells score with a 500 ng/mL D-dimer threshold exhibited 97.22% sensitivity (95% CI: 80.53–100.00) and 4.99% specificity (95% CI: 3.58–6.39). Using AADD increased the specificity to 7.81% (95% CI: 6.08–9.54) while maintaining sensitivity at 97.22% (95% CI: 93.43–100.00); similar results were observed for the Geneva score. The YEARS algorithm exhibited 86.11% sensitivity (95% CI: 78.12–94.10) and 32.75% specificity (95% CI: 29.73–35.78), whereas the PEGeD algorithm exhibited 86.11% sensitivity (95% CI: 78.12–94.10) and 34.06% specificity (95% CI: 31.00–37.12). The YEARS and PEGeD algorithms demonstrated better performance in patients with COVID-19 in terms of specificity and accuracy. Conclusion: COVID-19 infection did not significantly affect the diagnostic performances of the clinical algorithms for PE. YEARS and PEGeD performed better in patients with COVID-19, making them preferable. Higher D-dimer thresholds improved specificity but increased the risk of missed PE diagnoses.