Dissecting Diversity: Solid tumors are composed of functionally diverse tumor cells. The prevailing view is that this "intratumoral heterogeneity" arises from the accumulation of mutations during tumor growth, resulting in multiple genetically defined subclones of cells that respond in different ways to selective pressures such as chemotherapy.
Kreso
et al. (p. 543 , published online 13 December; see the Perspective by Marusyk and Polyak ) simultaneously monitored the genetic profiles and growth behavior of human colorectal cancer cells that were serially passaged in mice. Individual tumor cells within a uniform genetic lineage displayed extensive variation in survival, growth dynamics, and response to a chemotherapeutic drug. Thus, additional diversity-generating mechanisms such as epigenetic regulation or microenvironmental variability appear to operate within a genetic clone, endowing a subset of tumor cells with robust survival potential, especially during stress.
Failure of liver stiffness measurement (LSM) by transient elastography (TE, FibroScan) and unreliable results occur in ≈5% and 15% of patients, respectively, mainly due to obesity. In this multicenter study, we evaluated the feasibility and performance of the novel FibroScan XL probe in 276 patients with chronic liver disease (42% viral hepatitis, 46% nonalcoholic fatty liver disease [NAFLD]) and a body mass index (BMI) ≥28 kg/m2. Patients underwent liver biopsy and TE with the standard M and XL probes. TE failure was defined as no valid LSMs and unreliable examinations as <10 valid LSMs or an interquartile range (IQR)/LSM >30% or success rate <60%. Probe performance for diagnosing ≥F2 fibrosis and cirrhosis (F4) versus biopsy were examined using areas under receiver operating characteristic curves (AUROC). FibroScan failure was less frequent with the XL probe than the M probe (1.1% versus 16%) and the XL probe was more often reliable (73% versus 50%; both
P
< 0.00005). Reliable results with the XL probe were obtained in 61% of patients in whom the M probe was unreliable. Among 178 patients with ≥10 valid LSMs using both probes, liver stiffness was highly correlated between probes (ρ = 0.86;
P
< 0.0005); however, median liver stiffness was lower using the XL probe (6.8 versus 7.8 kPa;
P
< 0.00005). The AUROC of the XL and M probes were similar for ≥F2 fibrosis (0.83 versus 0.86;
P
= 0.19) and cirrhosis (0.94 versus 0.91;
P
= 0.28).
Conclusion
: Compared with the M probe, the FibroScan XL probe reduces TE failure and facilitates reliable LSM in obese patients. Although the probes have comparable accuracy, lower liver stiffness cutoffs will be necessary when the XL probe is used to noninvasively assess liver fibrosis. (Hepatology 2012)