Marc Toeteberg-Harms

Prof. Dr. Marc Toeteberg-Harms

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2011 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
SLStefan J. Langenegger
Stefan J. Langenegger
JFJens Funk
Jens Funk
MTMarc Toeteberg-Harms
Marc Toeteberg-Harms
To evaluate the impact of Spectralis self-acting eye-tracking (eye tracker) and retest software on the reproducibility of retinal nerve fiber layer (RNFL) thickness measurements in glaucomatous and healthy control eyes by SD-OCT. RNFL thickness was measured in 56 normal and 47 glaucomatous eyes by one operator within one session with a brief rest between measurements. Three measurements were taken with the eye tracker and the retest function engaged (method A), and three measurements were taken without the eye tracker and without the retest function (method B). Method A and B measurements were taken alternately. Reliability, measured by intraclass correlation coefficient (ICC) for absolute agreement and coefficient of variation (COV), was calculated for the global mean RNFL thickness (G), for each sector and for the peripapillary bundle. The ICC (and lower 95% confidence interval [CI]) for the global mean RNFL thickness (G) for method A measurements in both normal and glaucomatous eyes was 0.99 (0.98 CI). In glaucomatous eyes, the COV for method B measurements was between 2.7% and 10.5%, and between 1.3% and 3.5% for method A measurements. The reproducibility of RNFL measurements with Spectralis SD-OCT is excellent in both normal and glaucomatous eyes and can be significantly improved by using the eye tracker and retest software. The gain of reproducibility by using the software is significantly higher in glaucomatous eyes than in normal eyes. These findings suggest that software applications are capable of significantly improving the reproducibility of RNFL thickness measurements.

5 September 2013 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
CSCaterina Schweier
Caterina Schweier
JHJames V.M. Hanson
James V.M. Hanson
JFJens Funk
Jens Funk
MTMarc Toeteberg-Harms
Marc Toeteberg-Harms
Background: Icare PRO (ICP) is a new Rebound tonometer that is able to measure intraocular pressure (IOP) in both sitting and reclining positions. In this study, the gold standard Goldmann tonometer (GAT) was compared to ICP and Tono-Pen AVIA (TPA). Hypothesis was that repeatability of GAT is superior to ICP and TPA. Methods: 36 eyes of 36 healthy caucasian individuals, 13 male and 26 females, 17 right and 19 left eyes have been included in this prospective, randomized, cross-sectional study. The study was conducted at a single site (Dept. of Ophthalmology, UniversityHospital Zurich, Switzerland). Primary outcome measures were Intraclass correlation coefficients (ICC) and coefficients of variation (COV) and test-retest repeatability as visualized by Bland-Altman analysis. Secondary outcome measures were IOP in sitting (GAT, ICP and TPA) and in reclining (ICP and TPA) position. Results: Mean IOP measured by GAT was 14.9±3.5 mmHg. Mean IOP measured by ICP was 15.6±3.1 mmHg (with TPA 14.8±2.7 mmHg) in sitting and 16.5±3.5 mmHg (with TPA 17.0±3.0 mmHg) in reclining positions. COVs ranged from 2.9% (GAT) to 6.9% (ICP reclining) and ICCs from 0.819 (ICP reclining) to 0.972 (GAT). Conclusions: Repeatability is good with all three devices. GAT has higher repeatability compared to the two tested hand-held devices with lowest COVs and highest ICCs. IOP was higher in the reclining compared to the sitting position. Trial registration: The study was registered to the Clinical Trials Register of the US National Institute of Health, NCT01325324.

10 September 2011 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
MTMarc Toeteberg-Harms
Marc Toeteberg-Harms
VSVeit Sturm
Veit Sturm
PKPascal B. Knecht
Pascal B. Knecht
JFJens Funk
Jens Funk
MMMarcel N. Menke
Marcel N. Menke

24 June 2013 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
MTMarc Toeteberg-Harms
Marc Toeteberg-Harms
JHJames V.M. Hanson
James V.M. Hanson
JFJens Funk
Jens Funk
Cataract surgery combined with excimer laser trabeculotomy (phaco-ELT) can reduce intraocular pressure (IOP). The aim of this study was to evaluate the effect of phaco-ELT on IOP in patients as a function of preoperative IOP. Patients with open-angle glacuoma or ocular hypertension who received phaco-ELT between 01/2008 and 10/2009 were included. Patients were assigned based on preoperative IOP either to the study group (≤21 mmHg) or control group (>21 mmHg) in this IRB-approved, prospective, consecutive case series. Visual Acuity, IOP, and number of anti-glaucoma drugs (AGD) were recorded at baseline and 12 months after phaco-ELT. Any postoperative complications were also recorded. 64 eyes of 64 patients (76.5 ± 9.4 years) were included. Baseline IOP was 19.8 ± 5.3 mmHg (AGD 2.4 ± 1.1) for all eyes, 16.5 ± 2.9 mmHg (AGD 2.5 ± 1.0) for the study group, and 25.8 ± 2.9 mmHg (AGD 2.2 ± 1.4) for the control group. Across the two groups, IOP was reduced by 4.5 ± 5.9 mmHg (-23.0%, p < 0.001) and AGD by 0.9 ± 1.5 (-38.9%, p < 0.001). For the study group IOP was reduced by 1.9 ± 4.4 mmHg (-11. 5 %, p = 0.012) and AGD by 1.1 ± 1.4 (-42.9%, p < 0.001), and for the control group by 9.5 ± 5.4 mmHg (-36.6%, p < 0.001) and AGD by 0.7 ± 1.6 (-29.5%, p = 0.085). There were no serious postoperative complications such as endophthalmitis, significant hyphema, or a severe fibrinous reaction of the anterior chamber. IOP remained significantly reduced from baseline 12 months after phaco-ELT regardless of preoperative IOP levels, with no major complications. The IOP reduction remained constant over the entire follow-up. Hence, phaco-ELT can be considered in glaucoma and ocular hypertensive patients whenever cataract surgery is performed, in order to further reduce IOP or to reduce the requirement for IOP-reducing medications.

17 July 2012 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
SFSandra Furrer
Sandra Furrer
Marcel MenkeMarcel Menke
Marcel Menke
JFJens Funk
Jens Funk
MTMarc Toeteberg-Harms
Marc Toeteberg-Harms
Background: To determine the agreement between intraocular pressure and the ‘Wuerzburg bleb classification score’, as well as between single items of the score and intraocular pressure. Interobserver variability was analyzed. Methods: 57 post-trabeculectomy eyes were included. Colour photographs were used to score the filtering bleb in accordance to the Wuerzburg bleb classification score by two different examiners. At the same visit, clinical data such as intraocular pressure, best corrected visual acuity, slit lamp biomicroscopy and medical history were obtained by another examiner. Results: After trabeculectomy, 42 out of 57 eyes (73.7%) reached the target pressure (≤21mmHg, and intraocular pressure reduction of at least 20%, without antiglaucoma medication, and without any additional intervention). Fair agreement was found between intraocular pressure and Wuerzburg bleb classification score ≥8 points and ≥7 points (kappa 0.24 and 0.27, respectively). Analyzing the subgroups of the morphological criteria, best agreement was found between occurrence of microcysts and target intraocular pressure (к 0.22 – 0.34). Conclusions: Evaluating filtering blebs after trabeculectomy by using the Wuerzburg bleb classification score is a good technique for predicting intraocular pressure control in eyes attaining a minimum score of seven points. The presence of microcysts on the filtering bleb predicts that the eye is likely to attain target pressure.

1 February 2020 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
AIAlexandros S Ioannidis
Alexandros S Ioannidis
MTMarc Toeteberg-Harms
Marc Toeteberg-Harms
THTimothy Hamann
Timothy Hamann
CHChristopher Hodge
Christopher Hodge
Purpose: Simultaneous cataract and glaucoma surgery has traditionally been challenging for the anterior segment surgeon. The introduction of minimally invasive glaucoma surgery (MIGS) in conjunction with cataract surgery appears safe and effective in lowering intraocular pressure. Although a significant visual impact leading from the combined procedure is unexpected, we aim to describe the refractive outcomes in a cohort of patients undergoing simultaneous cataract removal and iStent inject and discuss the potential implications of combined surgery in patients with co-existent glaucoma. Patients and Methods: This is a retrospective consecutive case series inclusive of patients undergoing combined femtosecond laser-assisted cataract surgery and the insertion of two trabecular micro-bypass stents (iStent inject). Visual acuity, refraction and astigmatic vector analysis were collated and analysed from the preoperative and 4 weeks postoperative visits. Results: One hundred and six eyes of 89 patients from 2 surgeons were included in the original cohort. The mean absolute difference from target refraction was 0.36 ± 0.25D. 73.9% of eyes were within ± 0.5D of the refractive target and 98.9% of eyes were within ± 1.00D. 73.8% of eyes had 0.5D or less residual refractive astigmatism following the procedure. Conclusion: We present a novel cohort of glaucoma patients undergoing combined trabecular micro-bypass stents (iStent inject) and cataract surgery achieving excellent refractive outcomes. The results of this study indicate that this second-generation device is refractively neutral.