The broad family of viruses known as anelloviruses (AV) infects both humans and numerous animal species. They have a tiny, covalently closed single-stranded DNA genome and the astonishing capacity to infect a very high percentage of healthy and ill people with chronic infections that could last a lifetime. AV, and particularly the prototype Torquetenovirus, have established a successful interaction with the host's immune system and the rate at which they replicate is a gauge to measure overall immune function, even though many aspects of their life cycle and pathogenesis are still poorly understood.
Echovirus 11 (E11) has gained attention owing to its association with severe neonatal infections. Due to the limited data available, the World Health Organization (WHO) considers public health risk to the general population to be low. The present study investigated the genetic variation and molecular evolution of E11 genomes collected from May to December 2023. Whole genome sequencing (WGS) was performed for 16 E11 strains. Phylogenetic analysis on WG showed how all Italian strains belonged to genogroup D5, similarly to other E11 strains recently reported in France and Germany all together aggregated into separate clusters. A cluster‐specific recombination pattern was also identified using phylogenetic analysis of different genome regions. Echovirus 6 was identified as the major recombinant virus in 3Cpro and 3Dpol regions. The molecular clock analysis revealed that the recombination event probably occurred in June 2018 (95% HPD interval: Jan 2016–Jan 2020). Shannon entropy analyses, within P1 region, showed how 11 amino acids exhibited relatively high entropy. Five of them were exposed on the canyon region which is responsible for receptor binding with the neonatal Fc receptor. The present study showed the recombinant origin of a new lineage of E11 associated with severe neonatal infections.
The immune response after SARS-CoV-2 vaccine administration appears to be characterized by high inter-individual variation, even in SARS-CoV-2 positive subjects, who could have experienced different post-infection, unresolved conditions. We monitored anti-SARS-CoV-2 IgG levels and kinetics along with circulating biomarkers in a cohort of 175 healthcare workers during early immunization with COVID-19 mRNA-LNP BNT162b2 vaccine, to identify the associated factors. Subjects with a previous SARS-CoV-2 infection were characterized by higher BMI and CRP levels and lower neutrophil count with respect to naïve subjects. Baseline IgG levels resulted associated with CRP independently on BMI and inflammatory diseases. Among 137 subjects undergoing vaccination and monitored after the first and the second dose, three kinetic patterns were identified. The pattern showing a rapid growth was characterized by higher IgG levels at baseline and higher CRP and MCHC levels than negative subjects. Subjects previously exposed to SARS-CoV-2 showed higher levels of CRP, suggesting persistence of unresolved inflammation. These levels are the main determinant of IgG levels at baseline and characterized subjects belonging to the best performing, post-vaccine antibody kinetic pattern.
Objectives: Torquetenovirus (TTV) and Redondovirus (ReDoV) are the most prevalent viruses found in the human respiratory virome in viral metagenomics studies. A large-scale epidemiological study was performed to investigate their prevalence and loads in saliva samples according to SARS-CoV-2 status. Methods: Saliva samples from 448 individuals (73% SARS-CoV-2 negative and 27% SARS-CoV-2 positive) aged 23–88 years were tested. SARS-CoV-2 and TTV were determined in saliva by specific qualitative and quantitative real-time PCRs, respectively. A sub-cohort of 377 subjects was additionally tested for the presence and load of ReDoV in saliva, and a different sub-cohort of 120 subjects for which paired saliva and plasma samples were available was tested for TTV and ReDoV viremia at the same timepoints as saliva. Results: TTV in saliva was 72% prevalent in the entire cohort, at a mean DNA load of 4.6 log copies/mL, with no difference regardless of SARS-CoV-2 status. ReDoV was found in saliva from 61% of the entire cohort and was more prevalent in the SARS-CoV-2-negative subgroup (65% vs. 52%, respectively). In saliva, the total mean load of ReDoV was very similar to the one of TTV, with a value of 4.4 log copies/mL. The mean viral loads in subjects infected with a single virus, namely, those infected with TTV or ReDoV alone, was lower than in dually infected samples, and Tukey’s multiple-comparison test showed that ReDoV single-infected samples resulted in the only true outlier (p = 0.004). Differently from TTV, ReDoV was not detected in any blood samples. Conclusions: This study establishes the prevalence and mean value of TTV and ReDoV in saliva samples and demonstrates the existence of differences between these two components of the human virome.
With numbers of COVID-19 cases having substantially increased at the end of 2022 in China, some countries have started or expanded testing and genomic surveillance of travellers. We report screening results in Italy in late December 2022 of 556 flight passengers in provenance from two Chinese provinces. Among these passengers, 126 (22.7%) tested SARS-CoV-2 positive. Whole genome sequencing of 61 passengers’ positive samples revealed Omicron variants, notably sub-lineages BA.5.2.48, BF.7.14 and BQ.1.1, in line with data released from China.
Quantification of Torquetenovirus (TTV) viremia is becoming important for evaluating the status of the immune system in solid organ transplant recipients, monitoring the appearance of post-transplant complications, and controlling the efficacy of maintenance immunosuppressive therapy. Thus, diagnostic approaches able to scale up TTV quantification are needed. Here, we report on the development and validation of a real-time PCR assay for TTV quantification on the Hologic Panther Fusion® System by utilizing its open-access channel. The manual real-time PCR previously developed in our laboratories was optimized to detect TTV DNA on the Hologic Panther Fusion® System. The assay was validated using clinical samples. The automated TTV assay has a limit of detection of 1.6 log copies per ml of serum. Using 112 samples previously tested via manual real-time PCR, the concordance in TTV detection was 93% between the assays. When the TTV levels were compared, the overall agreement between the methods, as assessed using Passing–Bablok linear regression and Bland–Altman analyses, was excellent. In summary, we validated a highly sensitive and accurate method for the diagnostic use of TTV quantification on a fully automated Hologic Panther Fusion® System. This will greatly improve the turnaround time for TTV testing and better support the laboratory diagnosis of this new viral biomarker.