Guangfei Chen

Dr. Guangfei Chen

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2023 in Buildings
Verified
Journal Article
Open access
PDF file
RZRongguo Zhao
Rongguo Zhao
GCGuangfei Chen
Guangfei Chen
ZZZaihua Zhang
Zaihua Zhang
WLWei Luo
Wei Luo
To estimate the progressive collapse resistance capacity of a multi-column frame tube structure with an assembled truss beam composite floor (ATBCF), pushdown analysis and nonlinear dynamic analysis are conducted for such a structure using the alternate load path (ALP) method. The bearing capacities of the remaining structures under three different work conditions, which are the side middle column removal, the edge middle column removal, and the corner column removal, are individually studied, and the collapse mechanism of the remaining structures is analyzed based on the aspects of the internal force redistribution and the failure mode of the second defense line. Simultaneously, the influence of the column failure time on the dynamic response of the remaining structure and the dynamic amplification coefficient is discussed. The results indicate that the residual bearing capacity of the remaining structure following the bottom corner column removal is higher than that of the one following the side or edge middle column removal, while the latter has a stronger plastic deformation capacity. When the ALP method is adopted to operate the progressive collapse analysis, it is reasonable to take the column failure time as 0.1 times the period of the first-order vertical vibration mode of the remaining structure, and it is suitable to set the dynamic amplification coefficient as 2.0, which is the ratio of the maximum dynamic displacement to the static displacement of the remaining structure under the transient loading condition.

27 November 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
RZRongguo Zhao
Rongguo Zhao
GCGuangfei Chen
Guangfei Chen
ZZZaihua Zhang
Zaihua Zhang
WLWei Luo
Wei Luo
To estimate the progressive collapse resistance capacity of a multi-column frame tube structure with the assembled truss beam composite floor (ATBCF), the pushdown analysis, and the nonlinear dynamic analysis as well, are conducted for such a structure by using the alternate load path (ALP) method. The bearing capacities of the remaining structures at three different work conditions, which are the side middle column failure, the edge middle column failure, and the corner column failure, are individually studied, and the collapse mechanism for the remaining structures is analyzed from the aspects of the internal force redistribution and the failure mode of the second defense line. Simultaneously, the influence of the column failure time on the dynamic response of the remaining structure and the dynamic amplification coefficient are discussed. The results show that the residual bearing capacity of the remaining structure with the bottom corner column failure is higher than that of the one with the side or edge middle column failure, while the latter has a stronger plastic deformation capacity. When the ALP method is adopted to operate the progressive collapse analysis, it is reasonable to take the column failure time as 0.1 times of the first-order vertical vibration period of the remaining structure, and it is suitable to set the dynamic amplification coefficient as of 2.0, which is the ratio of the maximum dynamic displacement to the static displacement of the remaining structure under the transient loading condition.