Chaitanya Krishna Prasad Vallabh

Dr. Chaitanya Krishna Prasad Vallabh

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2023 in Precision Engineering
Verified
Journal Article
Closed access
HZHaolin Zhang
Haolin Zhang
CVChaitanya Krishna Prasad Vallabh
Chaitanya Krishna Prasad Vallabh
XZXiayun Zhao
Xiayun Zhao

1 May 2018 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
XXXiaochi Xu
Xiaochi Xu
CMConnor Mack
Connor Mack
ZCZachary J. Cleland
Zachary J. Cleland
CVChaitanya Krishna Prasad Vallabh
Chaitanya Krishna Prasad Vallabh
VDVivek S. Dave
Vivek S. Dave
CCCetin Cetinkaya
Cetin Cetinkaya
Currently, the compressed tablet and its oral administration is the most popular drug delivery modality in medicine. The accurate porosity and tensile strength characterization of a tablet design is vital for predicting its performance such as disintegration, dissolution, and drug-release efficiency upon administration as well as ensuring its mechanical integrity. In current work, a non-destructive contact ultrasonic approach and an associated testing procedure are presented and employed to quantify and relate the acoustically extracted mechanical properties of pharmaceutical compacts to direct porosity and tensile strength measurements. Based on a comprehensive set of experimental data, it is demonstrated how strongly the acoustic wave propagation is modulated and correlated to the tablet porosity and tensile strength of a compact made using spray-dried lactose and microcrystalline cellulose with varying mixture ratios. The effect of mixing ratio on the porosity and tensile strength on the resulting compacts is quantified and, with the acoustic experimental data, mixing ratio is related to the compact ultrasonic characteristics. The ultrasonic techniques provide a rapid, non-destructive means for evaluating compacts in formulation development and manufacturing. The presented approach and data could find critical applications in continuous tablet manufacturing, its real-time quality monitoring, as well as minimizing batch-to-batch quality variations.

22 June 2017 in Journal of Manufacturing Science and Engineering
Verified
Journal Article
Closed access
PDF file
XXXiaochi Xu
Xiaochi Xu
CVChaitanya Krishna Prasad Vallabh
Chaitanya Krishna Prasad Vallabh
ZCZachary James Cleland
Zachary James Cleland
CCCetin Cetinkaya
Cetin Cetinkaya
Additive manufacturing (AM) is rapidly becoming a local manufacturing modality in fabricating complex, custom-designed parts, providing an unprecedented form-free flexibility for custom products. However, significant variability in part geometric quality and mechanical strength due to the shortcomings of AM processes has often been reported. Presently, AM generally lacks in situ quality inspection capability, which seriously hampers the realization of its full potential in delivering qualified practical parts. Here, we present a monitoring approach and a periodic structure design for developing test artifacts for in situ real-time monitoring of the material and bonding properties of a part at fiber/bond-scale. While the production method used in current work is filament based, the proposed approach is generic as defects are always due to materials in a bonding zone and their local bonding attributes in any production modality. The artifact design detailed here is based on ultrasonic wave propagation in phononic coupons consisting of repeating substructures to monitor and eventually to assess the bond quality and placement uniformity—not only for geometry but also for defect states. Periodicity in a structure leads to the dispersion of waves, which is sensitive to geometric/materials properties and irregularities. In this proof-of-concept study, an experimental setup and basic artifact designs are described and off-line/real-time monitoring data are presented. As a model problem, the effects of printing speed on the formation of stop bands, wave propagation speeds and fiber placement accuracy in samples are detected and reported.

24 October 2018 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
XXXiaochi Xu
Xiaochi Xu
CVChaitanya Krishna Prasad Vallabh
Chaitanya Krishna Prasad Vallabh
SHStephen W. Hoag
Stephen W. Hoag
VDVivek S. Dave
Vivek S. Dave
CCCetin Cetinkaya
Cetin Cetinkaya
Capping is a common mechanical defect in tablet manufacturing, exhibited during or after the compression process. Predicting tablet capping in terms of process variables (e.g. compaction pressure and speed) and formulation properties is essential in pharmaceutical industry. In current work, a non-destructive contact ultrasonic approach for detecting capping risk in the pharmaceutical compacts prepared under various compression forces and speeds is presented. It is shown that the extracted mechanical properties can be used as early indicators for invisible capping (prior to visible damage). Based on the analysis of X-ray cross-section images and a large set of waveform data, it is demonstrated that the mechanical properties and acoustic wave propagation characteristics is significantly modulated by the tablet’s internal cracks and capping at higher compaction speeds and pressures. In addition, the experimentally extracted properties were correlated to the directly-measured porosity and tensile strength of compacts of Pearlitol®, Anhydrous Mannitol and LubriTose® Mannitol, produced at two compaction speeds and at three pressure levels. The effect compaction speed and pressure on the porosity and tensile strength of the resulting compacts is quantified, and related to the compact acoustic characteristics and mechanical properties. The detailed experimental approach and reported wave propagation data could find key applications in determining the bounds of manufacturing design spaces in the development phase, predicting capping during (continuous) tablet manufacturing, as well as online monitoring of tablet mechanical integrity and reducing batch-to-batch end-product quality variations.

1 September 2013 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
AVArmin Saeedi Vahdat
Armin Saeedi Vahdat
CVChaitanya Krishna Prasad Vallabh
Chaitanya Krishna Prasad Vallabh
BHBruno C. Hancock
Bruno C. Hancock
CCCetin Cetinkaya
Cetin Cetinkaya

20 February 2019 in 3D Printing and Additive Manufacturing
Verified
Journal Article
Closed access
XXXiaochi Xu
Xiaochi Xu
CVChaitanya Krishna Prasad Vallabh
Chaitanya Krishna Prasad Vallabh
AKAjay Krishnan
Ajay Krishnan
SVScott Volk
Scott Volk
CCCetin Cetinkaya
Cetin Cetinkaya
Additive manufacturing/3D printing (AM/3DP) has become a practical manufacturing modality in fabricating highly-complex/optimized parts, providing a form-free flexibility for the development of high-value/high-performance products. However, significant build-to-build variabilities in geometric tolerances and mechanical strength have often been reported as shortcomings. Currently, AM/3DP lacks a practical in situ /real-time quality monitoring utility. In fused filament fabrication, the quality of production in a uniform build depends on two fundamental parameters: the strength of each thread (an extruded line of filament material, created by the heated nozzle) and the nature/strength of thread-to-thread bonds in (in-plate) horizontal and (out-of-plane) vertical directions. In this study, we present an in situ /real-time monitoring approach, in which, instead of monitoring the actual build, the spectral characteristics of elastic wave propagation in a specially designed artifact having periodic internal structures are monitored. The design of an artifact is based on the geometric complexities of the actual build, and its internal structures amplify certain specified aspects of its AM/3DP process and materials. Furthermore, the artifact is substantially simpler and smaller than the actual build it represents, thus considerably easier to monitor. In this study, the artifact design consists of repeating biperiodic substructures of sparsely located threads. As a model problem, in this study we introduce and report a simple phononic crystal artifact design with varying thread-crossing angles and the effects of thread orientation and placement on the shifts of its pass and stop bands and/or the creation of stop bands. In current proof-of-concept study, an experimental setup and basic artifact designs are described, off-line monitoring data are presented, and the sensitivity of the approach is analyzed.