Skin is a critical organ that plays a crucial role in defending the internal organs of the body. For this reason, extensive work has gone into creating artificial models of the epidermis for in vitro skin toxicity tests. These tissue models, called reconstructed human epidermis (RhE), are used by researchers in the pharmaceutical, cosmetic, and environmental arenas to evaluate skin toxicity upon exposure to xenobiotics. Here, we present a label-free solution that leverages the use of the intelligent mobile lab for in vitro diagnostics (IMOLA-IVD), a noninvasive, sensor-based platform, to monitor the transepithelial electrical resistance (TEER) of RhE models and adherent cells cultured on porous membrane inserts. Murine fibroblasts cultured on polycarbonate membranes were first used as a test model to optimize procedures using a custom BioChip encapsulation design, as well as dual fluidic configurations, for continuous and automated perfusion of membrane-bound cultures. Extracellular acidification rate (EAR) and TEER of membrane-bound L929 cells were monitored. The developed protocol was then used to monitor the TEER of MatTek EpiDermTM RhE models over a period of 48 h. TEER and EAR measurements demonstrated that the designed system is capable of maintaining stable cultures on the chip, monitoring metabolic parameters, and revealing tissue breakdown over time.
The flexible and modular setup of an intelligent mobile lab (IMOLA) that can be equipped with biosensor chips for monitoring of cellular metabolism is described. An application as an environmental monitoring system is described by recording the extracelluar acidification and cellular respiration of Chlorella kessleri after exposure to the herbicide metamitron. The adaptability of the IMOLA system to future developments in the field of biosensors or cellular metabolism analysis is emphasized.
Cell culture techniques are strongly connected with modern scientific laboratories and production facilities. Thus, choosing the most suitable medium for the cells involved is vital, not only directly to optimise cell viability but also indirectly to maximise the reliability of the experiments performed with the cells. Fetal bovine or calf serum (FBS or FCS, respectively) is the most commonly used cell culture medium supplement, providing various nutritional factors and macromolecules essential for cell growth. Yet, the use of FBS encompasses a number of disadvantages. Scientifically, one of the most severe disadvantages is the lot-to-lot variability of animal sera that hampers reproducibility. Therefore, transitioning from the use of these ill-defined, component-variable, inconsistent, xenogenic, ethically questionable and even potentially infectious media supplements, is key to achieving better data reproducibility and thus better science. To demonstrate that the transition to animal component-free cell culture is possible and achievable, we highlight three different scenarios and provide some case studies of each, namely: i) the adaptation of single cell lines to animal component-free culture conditions by the replacement of FBS and trypsin; ii) the adaptation of multicellular models to FBS-free conditions; and (iii) the replacement of FBS with human platelet lysate (hPL) for the generation of primary stem/stromal cell cultures for clinical purposes. By highlighting these examples, we aim to foster and support the global movement towards more consistent science and provide evidence that it is indeed possible to step out of the currently smouldering scientific reproducibility crisis.
During recent years, sensor chip-based systems have been developed which monitor functional changes of living cells. Key elements of such cellular assays are silicon or glass chips with integrated sensors for physico-chemical parameters, i.e. pH, pO2, electric impedance and temperature. Analysis of these primary parameters yields information about cell metabolism, cell growth and adhesion, and cell morphological changes. The operation principles of individual sensor types are described together with examples of experimental results.
1 February 2007 in Biomedical Engineering / Biomedizinische Technik
Cells are organic microsystems with functional compartments interconnected by complex signal chains. Intracellular signaling routes and signal reception from the extracellular environment are characterized by redundancy, i.e., parallel pathways exist. If a cell is exposed to an external "signal input", the signal processing elements within the cell provide a response that will be a pattern of reactions manifest as a metabolic, morphologic or electric "signal output". Cell-chip hybrid structures are miniaturized analytical systems with the capability to monitor such cell responses in real time and under continuous control of the environmental conditions. A system analysis approach gives an idea of how the biological component of these hybrid structures works. This is exemplified by the putative role of the microenvironmental pH as a parameter of the utmost importance for the malignant "mode" of tumor cells, which can be monitored and modeled on such hybrid structures.