Introduction. The aim of this study is to compare the root canal transportation with the PathFile-ProTaper recommended protocol, PathFile-ProTaper modified protocol and stainless steel K-flexofiles. Methods. Forty-five ISO 15, 0.02 taper S-shaped Endo Training Blocks were divided randomly into three groups of 15 each and prepared as follows: PathFile-Protaper recommended protocol, Pathfile-Protaper modified protocol and manual preparation with K-Flexofiles. The amount of transportation was assessed by scanning the blocks before and after preparation and superimposing the images. The cutting effects of the instruments from the inner and outer aspects of the root canals were measured and statistically analyzed with the One-way Anova test and Tukey HSD test. Results. Manual preparation caused significantly more transportation than both PathFile-Protaper systems. There was no significant difference regarding transportation between the two Pathfile-Protaper protocols. Conclusion. The modified Pathfile-Protaper protocol transported the canal similar to the recommended Pathfile-Protaper protocol. It may be suggested that, while working safety remains unchanged, the shaping procedure and consequently working time can be shortened with fewer instruments. The results of this study can help clinicians to reduce the preparation time with the PathFile-ProTaper rotary system while the preparation quality remains the same.
Recently developed Nickel-Titanium (NiTi) instruments with practical changes have resulted in safer instrumentation. In addition, topographical features on the file surface are a contributing factor to clinical durability. Therefore, this study aimed to investigate both the cyclic fatigue resistance and the roughness change of MTwo and Rotate instruments (VDW, Munich, Germany). Each instrument (n = 6/each group) was scanned with an atomic force microscopy prior to and after instrumentation. In addition, cyclic fatigue testing was conducted for each instrument (n = 11/each group) with stainless-steel blocks, including 45°-60°-90° degrees of curvature milled to the instruments’ size. The roughness parameters increased for both systems after instrumentation (p<0.05). Both systems presented an increased roughness following instrumentation (p<0.05). The cyclic fatigue resistance was lowest at 90° for both systems (p<0.05), whereas the Rotate files presented a higher resistance than that of the Mtwo files (p<0.05). Compared to the Mtwo files, Rotate files presented better resistance, while the resistance decreased as the curvature increased.
Objective: This study aimed to evaluate the accuracy, consistency, and scientific reliability of two AI-powered chatbots—ChatGPT-3.5 and ChatGPT-4o—in clinical endodontic decision-making, using the recently published European Society of Endodontology (ESE) S3-level Clinical Practice Guideline as the gold standard reference. Material and Methods: Twenty-five dichotomous (yes/no) questions were developed based on the ESE guideline and presented to both chatbots across three time intervals, yielding 300 total responses. Each response was evaluated for accuracy and consistency, and the quality of the supporting references was assessed according to their journal ranking (Q1, Q2, others). Results: Both ChatGPT versions demonstrated high internal consistency across repeated measurements. ChatGPT-3.5 showed 94.4% agreement (κ = 0.824; 95% confidence interval [CI]: 0.786–0.898; p < 0.001), whereas ChatGPT-4o demonstrated 98.9% agreement (κ = 0.937; 95% CI: 0.893–0.965; p < 0.001). The accuracy of ChatGPT-3.5 relative to the guideline-based answers was 81.4%, 88.9%, and 82.2% in the morning, afternoon, and evening sessions, respectively, while ChatGPT-4o achieved 82.9%, 83.3%, and 85.4%, respectively. No statistically significant differences were observed between the models across the three time intervals (p > 0.05). The proportion of Q1/Q2-ranked references was high and comparable between ChatGPT-3.5 (74–82%) and ChatGPT-4o (76–84%).Conclusion: Both ChatGPT-3.5 and ChatGPT-4o demonstrated substantial alignment with the ESE S3-level clinical practice guideline. However, these findings should not be interpreted as definitive assessments of current clinical conversational AI systems, and further evaluation of evolving models is required.