The goal of this work is to compare the differences between various step counting algorithms using both accelerometer and gyroscope measurements from wrist and ankle-mounted sensors. Participants completed four different conditions on a treadmill while wearing an accelerometer and gyroscope on the wrist and the ankle. Three different step counting techniques were applied to the data from each sensor type and mounting location. It was determined that using gyroscope measurements allowed for better performance than the typically used accelerometers, and that ankle-mounted sensors provided better performance than those mounted on the wrist.
2 January 2019 in Journal of Medical Engineering & Technology
With the rising popularity of activity tracking, there is a desire to not only count the number of steps a person takes, but also identify the type of step (e.g., walking or running) they are taking. For rehabilitation and athletic training, this difference is important to the prescribed regiment. Fourteen healthy adults walked, jogged and ran on a treadmill at three different constant speeds (1.21, 2.01, 2.68 m/s) for 90 s. An inertial measurement unit (IMU) with accelerometer and gyroscope was affixed to their left ankle. Collected acceleration and angular velocity data were partitioned into individual time-normalised strides. These data were used as features in the artificial neural network (ANN) that classified the type of stride. Several ANN models were tested: using only acceleration, only angular velocity and both. Using primarily acceleration data in the trained ANN yielded the best results (>94% correct stride-type identification) after cross-validation. The ANN models were able to accurately classify the gait type of each stride using a single wearable IMU. The accuracy of the method should improve further as more data is added to the ANN training.
The knee flexion angle is an important measurement for studies of the human gait. Running is a common activity with a high risk of knee injury. Studying the running gait in realistic situations is challenging because accurate joint angle measurements typically come from optical motion-capture systems constrained to laboratory settings. This study considers the use of shank and thigh inertial sensors within three different filtering algorithms to estimate the knee flexion angle for running without requiring sensor-to-segment mounting assumptions, body measurements, specific calibration poses, or magnetometers. The objective of this study is to determine the knee flexion angle within running applications using accelerometer and gyroscope information only. Data were collected for a single test participant (21-year-old female) at four different treadmill speeds and used to validate the estimation results for three filter variations with respect to a Vicon optical motion-capture system. The knee flexion angle filtering algorithms resulted in root-mean-square errors of approximately three degrees. The results of this study indicate estimation results that are within acceptable limits of five degrees for clinical gait analysis. Specifically, a complementary filter approach is effective for knee flexion angle estimation in running applications.