Maiko Iwaki

Dr. Maiko Iwaki


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2020 in Materials
Verified
Journal Article
Open access
PDF file
THTamaki Hada
Tamaki Hada
MKManabu Kanazawa
Manabu Kanazawa
MIMaiko Iwaki
Maiko Iwaki
TAToshio Arakida
Toshio Arakida
YSYumika Soeda
Yumika Soeda
SMShunsuke Minakuchi
Shunsuke Minakuchi
This study evaluated the effects of the differences in the printing directions of stereolithography (SLA) three-dimensional (3D)-printed dentures on accuracy (trueness and precision). The maxillary denture was designed using computer-aided design (CAD) software with an STL file (master data) as the output. Three different printing directions (0°, 45°, and 90°) were used. Photopolymer resin was 3D-printed (n = 6/group). After scanning all dentures, the scanning data were saved/output as STL files (experimental data). For trueness, the experimental data were superimposed on the master data sets. For precision, the experimental data were selected from six dentures with three different printing directions and superimposed. The root mean square error (RMSE) and color map data were obtained using a deviation analysis. The averages of the RMSE values of trueness and precision at 0°, 45°, and 90° were statistically compared. The RMSE of trueness and precision were lowest at 45°, followed by 90°; the highest occurred at 0°. The RMSE of trueness and precision were significantly different among all printing directions (p < 0.05). The highest trueness and precision and the most favorable surface adaptation occurred when the printing direction was 45°; therefore, this may be the most effective direction for manufacturing SLA 3D-printed dentures.


26 May 2021 in Polymers
Verified
Journal Article
Open access
PDF file
THTamaki Hada
Tamaki Hada
MKManabu Kanazawa
Manabu Kanazawa
MIMaiko Iwaki
Maiko Iwaki
AKAwutsadaporn Katheng
Awutsadaporn Katheng
SMShunsuke Minakuchi
Shunsuke Minakuchi
In this study, the physical properties of a custom block manufactured using a self-polymerizing resin (Custom-block), the commercially available CAD/CAM PMMA disk (PMMA-disk), and a heat-polymerizing resin (Conventional PMMA) were evaluated via three different tests. The Custom-block was polymerized by pouring the self-polymerizing resin into a special tray, and Conventional PMMA was polymerized with a heat-curing method, according to the manufacturer’s recommended procedure. The specimens of each group were subjected to three-point bending, water sorption and solubility, and staining tests. The results showed that the materials met the requirements of the ISO standards in all tests, except for the staining tests. The highest flexural strength was exhibited by the PMMA-disk, followed by the Custom-block and the Conventional PMMA, and a significant difference was observed in the flexural strengths of all the materials (p < 0.001). The Custom-block showed a significantly higher flexural modulus and water solubility. The water sorption and discoloration of the Custom-block were significantly higher than those of the PMMA-disk, but not significantly different from those of the Conventional PMMA. In conclusion, the mechanical properties of the three materials differed depending on the manufacturing method, which considerably affected their flexural strength, flexural modulus, water sorption and solubility, and discoloration.

1 October 2018 in Journal of Prosthodontic Research
Verified
Journal Article
Closed access
MKManabu Kanazawa
Manabu Kanazawa
MIMaiko Iwaki
Maiko Iwaki
TAToshio Arakida
Toshio Arakida
SMShunsuke Minakuchi
Shunsuke Minakuchi
This article describes the protocol of a digital impression technique to make an impression and recording of the jaw relationship of edentulous patients for the fabrication of CAD/CAM custom tray using computer-aided design and manufacturing (CAD/CAM) technology. Scan the maxillary and mandibular edentulous jaws using an intraoral scanner. Scan the silicone jig with the maxillary and mandibular jaws while keeping the jig between the jaws. Import the standard tessellation language data of the maxillary and mandibular jaws and jig to make a jaw relation record and fabricate custom trays (CAD/CAM trays) using a rapid prototyping system. Make a definitive impression of the maxillary and mandibular jaws using the CAD/CAM trays. Digitalization of the complete denture fabrication process can simplify the complicated treatment and laboratory process of conventional methods In addition, the proposed method enables quality control regardless of the operator's experience and technique.

Verified
Journal Article
Open access
PDF file
THTamaki Hada
Tamaki Hada
MKManabu Kanazawa
Manabu Kanazawa
NMNanako Miyamoto
Nanako Miyamoto
HLHengyi Liu
Hengyi Liu
MIMaiko Iwaki
Maiko Iwaki
SMShunsuke Minakuchi
Shunsuke Minakuchi
Photopolymer resins are widely used in the production of dental prostheses, but their mechanical properties require improvement. We evaluated the effects of different zirconia filler contents and printing directions on the mechanical properties of photopolymer resin. Three-dimensional (3D) printing was used to fabricate specimens using composite photopolymers with 0 (control), 3, 5, and 10 wt.% zirconia filler. Two printing directions for fabricating rectangular specimens (25 mm × 2 mm × 2 mm) and disk-shaped specimens (φ10 mm × 2 mm) were used, 0° and 90°. Three-point bending tests were performed to determine the flexural strengths and moduli of the specimens. The Vickers hardness test was performed to determine the hardness of the specimens. Tukey’s multiple comparison tests were performed on the average values of the flexural strengths, elastic moduli, and Vickers hardness after one-way ANOVA (α = 0.05). The flexural strengths and elastic moduli at 0° from high to low were in the order of 0, 3, 10, and 5 wt.%, and those at 90° were in the order of 3, 0, 10, and 5 wt.% (p < 0.05). For 5 and 10 wt.%, no significant differences were observed in mechanical properties at 0° and 90° (p < 0.05). The Vickers hardness values at 0° and 90° from low to high were in the order of 0, 3, 5, and 10 wt.% (p < 0.05). Within the limits of this study, the optimal zirconia filler content in the photopolymer resin for 3D printing was 0 wt.% at 0° and 3 wt.% at 90°.

9 November 2016 in Trials
Verified
Journal Article
Open access
PDF file
YKYuriko Komagamine
Yuriko Komagamine
MKManabu Kanazawa
Manabu Kanazawa
MIMaiko Iwaki
Maiko Iwaki
AJAyami Jo
Ayami Jo
HSHiroyuki Suzuki
Hiroyuki Suzuki
SMShunsuke Minakuchi
Shunsuke Minakuchi
Individuals who are edentulous have a lower intake of fruit, vegetables, fiber, and protein compared with their dentate counterparts because tooth loss is accompanied by a decrease in ability to chew. Whether or not a combination of prosthetic rehabilitation and simple dietary advice produces improvement in dietary intake among edentulous persons is unclear. We aim to investigate the effect of a simultaneous combination of simple dietary advice delivered by dentists and provision of new complete dentures on dietary intake in edentulous individuals who request new dentures. Through a double-blinded, parallel, randomized controlled trial in which 70 edentate persons who request new complete dentures will be enrolled, eligible study participants will be randomly allocated to either a dietary intervention group receiving dietary advice or to a control group receiving only advice on the care and maintenance of dentures. Outcome measures include daily intake of nutrients and food items, assessed using a brief self-administered diet history questionnaire; antioxidant capacity, determined using blood and urine samples; nutritional status, assessed with the Mini-Nutritional Assessment-Short Form; oral health-related quality of life, assessed with the Japanese version of the Oral Health Impact Profile-EDENT and the Geriatric Oral Health Assessment Index; subjective chewing ability; masticatory performance, assessed using a color-changeable chewing gum and a gummy jelly; patient self-assessment of dentures; mild cognitive impairment, assessed with the Japanese version of the Montreal Cognitive Assessment; and functional capacity, assessed with the Japan Science and Technology Agency Index of Competence. Outcome measures, except for antioxidant capacity, are to be implemented at three time points: at baseline and at 3 and 6 months following intervention. Antioxidant capacity data are to be collected twice: at baseline and at 3 months following intervention. Differences between the groups at 3 and 6 months and within-group changes are to be compared using the paired t test. Simple dietary advice that can be implemented by a dentist would be more practical in clinical practice than tailored dietary counseling. The results of this study will provide beneficial information on dietary intake changes for both edentulous individuals requesting new complete dentures and dentists. University Hospital Medical Information Network Center Unique Trial Number: UMIN000017879 . Registered on 12 June 2015.