Many volatile organic compounds (VOC) are classified as known or possible human carcinogens, irritants, and toxicants, and VOC exposure has been associated with asthma and other respiratory symptoms/diseases. This review summarizes recent quantitative data regarding VOC in four categories of indoor environments (schools, housing, offices, and other indoor) and compares the types and concentration levels of individual VOC that were detected, measured, and reported according to season (cold and warm). The influence of outdoor air on concentrations of indoor VOC was also assessed as ratios of indoor versus outdoor. Papers published from 2000 onward were reviewed and 1383 potentially relevant studies were identified. From these, 177 were removed after duplication, 1176 were excluded for not meeting the review criteria, and 40 were included in this review. On average, higher mean concentrations of indoor VOC were found in housing environments, in offices, and in the cold season. Volatile organic compounds are commonly present in indoor air and specific compounds, and their concentrations vary among indoor environments and seasons, indicating corresponding differences in sources (indoors and outdoors). Actions and policies to reduce VOC exposures, such as improved product labeling and consumer education, are recommended.
We aimed to assess the value and classification rate of exhaled volatile organic compounds (VOCs) in asthma diagnosis. A PRISMA‐oriented systematic search for published studies regarding exhaled VOCs in asthma diagnosis was conducted based on predefined criteria. Studies presenting sensitivity and specificity values for the test were included in the meta‐analysis. Pooled diagnosis odds ratios (DOR), area under the curve (AUC) and positive and negative likelihood ratios (LR) for exhaled VOC profiles were calculated; and publication bias, threshold effect and heterogeneity were estimated. Eighteen studies were selected for the qualitative analysis and six met the criteria for inclusion in the quantitative analysis. Mean (95% CI) pooled DOR, positive and negative LR were 49.3 (15.9–153.3), 5.86 (3.07–11.21) and 0.16 (0.10–0.26), respectively. The AUC value was 0.94. Only three of the 18 reviewed studies performed an external validation of the model using a different data set. The results from the revised studies suggest that exhaled VOCs are promising biomarkers for asthma diagnosis and that several compounds, mainly alkanes, may be significantly associated with asthma inflammation. However, there are still various constraints associated with standardization and externally validated studies are needed to introduce exhaled VOC profiling in a clinical scenario.