The present work aims to address a comprehensive analytical analysis of a new accurate equivalent electrical model of silicon photomultiplier (SiPM) detectors. The proposed circuit model allows to truthfully reproduce the output signal waveform generated by the light sensors apart from the specific technology adopted for the fabrication process, and can also be profitably exploited to perform reliable circuit-level simulations. A detailed and in-depth investigation of the functional parameters involved in the output pulse signals is here developed, and the most significant physical relationships are analytically derived as well. Experimental measurements are finally carried out on real devices, in order to validate the accuracy of the attained expressions, and good fittings are achieved between the analytical curve plots and the associated measurements results. The adopted analysis turns out to be particularly helpful when designing an optimum front-end architecture for SiPM detectors, since the performance of the entire detection system, especially in terms of dynamic range and timing resolution, can be accurately predicted as a function of the SiPM model parameters and the foremost features of the coupled front-end electronics.
1 July 2024 in Journal of Cosmology and Astroparticle Physics
Monochromatic gamma-ray signals constitute a potential smoking gun signature for annihilating or decaying dark matter particles that could relatively easily be distinguished from astrophysical or instrumental backgrounds. We provide an updated assessment of the sensitivity of the Cherenkov Telescope Array (CTA) to such signals, based on observations of the Galactic centre region as well as of selected dwarf spheroidal galaxies. We find that current limits and detection prospects for dark matter masses above 300 GeV will be significantly improved, by up to an order of magnitude in the multi-TeV range. This demonstrates that CTA will set a new standard for gamma-ray astronomy also in this respect, as the world's largest and most sensitive high-energy gamma-ray observatory, in particular due to its exquisite energy resolution at TeV energies and the adopted observational strategy focussing on regions with large dark matter densities. Throughout our analysis, we use up-to-date instrument response functions, and we thoroughly model the effect of instrumental systematic uncertainties in our statistical treatment. We further present results for other potential signatures with sharp spectral features, e.g. box-shaped spectra, that would likewise very clearly point to a particle dark matter origin.
At Mount Etna volcano, the focus point of persistent tectonic extension is represented by the Summit Craters. A muographic telescope has been installed at the base of the North-East Crater from August 2017 to October 2019, with the specific aim to find time related variations in the density of volcanic edifice. The results are significant, since the elaborated images show the opening and evolution of different tectonic elements; in 2017, a cavity was detected months before the collapse of the crater floor and in 2018 a set of underground fractures was identified, at the tip of which, in June 2019, a new eruptive vent started its explosive activity, still going on (February, 2020). Although this is the pilot experiment of the project, the results confirm that muography could be a turning point in the comprehension of the plumbing system of the volcano and a fundamental step forward to do mid-term (weeks/months) predictions of eruptions. We are confident that an increment in the number of telescopes could lead to the realization of a monitoring system, which would keep under control the evolution of the internal dynamic of the uppermost section of the feeding system of an active volcano such as Mount Etna.
A comprehensive and in-depth characterization procedure for obtaining very accurate measurements on silicon photomultiplier detectors (SiPMs) is here described. A large amount of optical tests are systematically carried out and discussed in terms of the most important SiPM performance parameters; in particular, an accurate estimation of the photon detection efficiency in the 350-900-nm wavelength spectral range and in steps of 10 nm is achieved, based on the single-photon counting technique, with substraction of the dark noise contribution and avoiding the additional noise sources of crosstalk and afterpulsing. Some recently produced detectors are analyzed and their relevant electro-optical parameters are evaluated in order to demonstrate the effectiveness and efficacy of the adopted characterization procedure and data-handling protocols in assessing the overall SiPM performance, regardless of the specific device tested. Tests repeatibility is carefully verified and all the evaluated parameter trends are proved to be compatible with the physics theory of the SiPM device.