Alessandro Grillo

Dr. Alessandro Grillo

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2022 in Journal of High Energy Astrophysics
Verified
Journal Article
Open access
SSSalvatore Scuderi
Salvatore Scuderi
Andrea GiulianiAndrea Giuliani
Andrea Giuliani
GPGiovanni Pareschi
Giovanni Pareschi
GTG. Tosti
G. Tosti
OCO. Catalano
O. Catalano
RSR. Zanmar Sanchez
R. Zanmar Sanchez

1 September 2015 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
DID. Impiombato
D. Impiombato
SGS. Giarrusso
S. Giarrusso
TMT. Mineo
T. Mineo
OCO. Catalano
O. Catalano
CGC. Gargano
C. Gargano
GRGiuseppe Romeo
Giuseppe Romeo

11 November 2013 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
DMD. Marano
D. Marano
MBM. Belluso
M. Belluso
GBGiovanni Bonanno
Giovanni Bonanno
SBS. Billotta
S. Billotta
AGAlessandro Grillo
Alessandro Grillo
SGS. Giarrusso
S. Giarrusso
The present work aims to address a comprehensive analytical analysis of a new accurate equivalent electrical model of silicon photomultiplier (SiPM) detectors. The proposed circuit model allows to truthfully reproduce the output signal waveform generated by the light sensors apart from the specific technology adopted for the fabrication process, and can also be profitably exploited to perform reliable circuit-level simulations. A detailed and in-depth investigation of the functional parameters involved in the output pulse signals is here developed, and the most significant physical relationships are analytically derived as well. Experimental measurements are finally carried out on real devices, in order to validate the accuracy of the attained expressions, and good fittings are achieved between the analytical curve plots and the associated measurements results. The adopted analysis turns out to be particularly helpful when designing an optimum front-end architecture for SiPM detectors, since the performance of the entire detection system, especially in terms of dynamic range and timing resolution, can be accurately predicted as a function of the SiPM model parameters and the foremost features of the coupled front-end electronics.

4 June 2014 in IEEE Sensors Journal
Verified
Journal Article
Closed access
GBGiovanni Bonanno
Giovanni Bonanno
DMDavide Marano
Davide Marano
MBMassimiliano Belluso
Massimiliano Belluso
SBSergio Billotta
Sergio Billotta
AGAlessandro Grillo
Alessandro Grillo
MTMaria Cristina Timpanaro
Maria Cristina Timpanaro
A comprehensive and in-depth characterization procedure for obtaining very accurate measurements on silicon photomultiplier detectors (SiPMs) is here described. A large amount of optical tests are systematically carried out and discussed in terms of the most important SiPM performance parameters; in particular, an accurate estimation of the photon detection efficiency in the 350-900-nm wavelength spectral range and in steps of 10 nm is achieved, based on the single-photon counting technique, with substraction of the dark noise contribution and avoiding the additional noise sources of crosstalk and afterpulsing. Some recently produced detectors are analyzed and their relevant electro-optical parameters are evaluated in order to demonstrate the effectiveness and efficacy of the adopted characterization procedure and data-handling protocols in assessing the overall SiPM performance, regardless of the specific device tested. Tests repeatibility is carefully verified and all the evaluated parameter trends are proved to be compatible with the physics theory of the SiPM device.

4 June 2014 in IEEE Sensors Journal
Verified
Journal Article
Closed access
GBGiovanni Bonanno
Giovanni Bonanno
DMDavide Marano
Davide Marano
MBMassimiliano Belluso
Massimiliano Belluso
SBSergio Billotta
Sergio Billotta
AGAlessandro Grillo
Alessandro Grillo
MTMaria Cristina Timpanaro
Maria Cristina Timpanaro
A comprehensive and in-depth characterization procedure for obtaining very accurate measurements on silicon photomultiplier (SiPM) detectors is described here. A large amount of electro-optical tests are systematically carried out in terms of the most significant SiPM performance parameters; in particular, an accurate estimation of the photon detection efficiency is achieved, based on the single-photon counting technique, with substraction of the dark noise contribution and avoiding the additional noise sources of crosstalk and after pulsing. Some recently produced detectors are analyzed and their relevant electro-optical parameters are evaluated in order to confirm the effectiveness and efficacy of the adopted characterization procedure in assessing the overall SiPM performance. The repeatibility of measurements is carefully verified. All evaluated parameter trends are proved to be compatible with the physics theory of the SiPM device.

1 October 2013 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
DMD. Marano
D. Marano
GBGiovanni Bonanno
Giovanni Bonanno
MBM. Belluso
M. Belluso
SBS. Billotta
S. Billotta
AGAlessandro Grillo
Alessandro Grillo
SGS. Giarrusso
S. Giarrusso