In many circumstances, decisions are based on subjective experience. However, some views can be vague, meaning that policymakers do not know exactly how they should express their opinions. Therefore, it is necessary for researchers to provide scientific decision frameworks, among which the multi-criteria decision making (MCDM) method in the linguistic environment is gradually favored by scholars. A large body of literature reports relevant approaches with regard to linguistic term sets, but existing approaches are insufficient to express the subjective thoughts of policymakers in a complex and uncertain environment. In this paper, we address this problem by introducing the concept of evidential linguistic term set (ELTS). ELTS generalizes many other uncertainty representations under linguistic context, such as fuzzy sets, probabilities, or possibility distributions. Measures on ELTS, such as uncertainty measure, dissimilarity measure and expectation function, provide general frameworks to handle uncertain information. Modeling and reasoning of information expressed by ELTSs are realized by the proposed aggregation operators. Subsequently, this paper presents a novel MCDM approach called evidential linguistic ELECTRE method, and applies it to the case of selection of emergency shelter sites. The findings demonstrate the effectiveness of the proposed method for MCDM problems under linguistic context and highlight the significance of the developed ELTS.
This study designed integrated constructed wetland–microbial fuel cell (CW–MFC) systems using activated carbon (AC) as both CW substrates and MFC anodes and investigated the structure-activity relationship of six kinds of commercial columnar AC, as well as the organics and nitrogen removal, microbial activity and diversity of CW–MFCs. Results showed that the nitrogen adsorption by AC tended to be a linear process in which physical adsorption played a leading role and micropores made great contributions. A higher specific surface area, developed mesopores, and oxygen functionalities were conducive to the capacitance properties of AC, while a higher specific surface area and developed micropores were conducive to reduce material resistance and improve ion permeability. Coconut-shell-based AC had both excellent nitrogen adsorption capacity and electrochemical properties, making it ideal as both CW substrates and MFC anodes for CW–MFCs. The electricity generation, coulombic efficiency, internal resistance, and organics and nitrogen removal of CW–MFCs were positively correlated with the total depth of AC anodes. The total depth of AC anodes can be determined based on the influent organics/nitrogen loadings and organics/nitrogen removal load of AC, and a relatively smaller depth of a single AC anode (5 cm) was recommended. The MFC effectively improved the enzymatic activity (by 10.33% dehydrogenase, 8.72% catalase, and 7.35% ammonia monooxygenase), nitrification/denitrification intensity (by 9.53%/6.68%), and microbial diversity (by 1.64–4.07%) of AC (MFC anodes) in CW–MFCs, while the depth of a single AC anode barely influenced the microbial activity and diversity. MFCs increased COD and NH3-N removal in CW–MFCs by 11.60% and 3.4%, respectively. The increased total adsorption capacity of AC with the increase of its total depth narrowed the difference in COD removal resulting from the promotion of MFCs on organics degradation. MFCs increased TN removal in CW–MFCs by 5.29% through promoting denitrification in cathodes and enhancing NH3-N assimilation in anodes. The phyla of EAB (Proteobacteria, Bacteroidetes, Firmicutes, and Acidobacteria) and genera of EAB (Citrobacter, Geobacter, and Pseudomonas) accounted for 85–86% and 15.58–16.64% of the microbial community on AC anodes in CW–MFCs, respectively.
Constructed wetland–microbial fuel cell coupling systems (CW–MFCs) have received significant academic interest in the last decade mainly due to the promotion of MFCs in relation to pollutants’ degradation in CWs. Firstly, we investigated the effect of hydraulic retention time (HRT) and electrode configuration on the flow field characteristics of CW–MFCs using graphite rods and plates as electrodes, as well as the optimization of electrode configuration using computational fluid dynamics (CFD) numerical simulation. The results showed that: (1) the apparent HRT was the most influential and decisive factor, with a contribution of over 90% for the average HRT of CW–MFCs; (2) anode spacing was the most influential factor for the hydraulic performance of CW–MFCs, with contributions of over 50% for water flow divergence and hydraulic efficiency (λ) and over 45% for effective volume ratio (e); (3) anode size was significant for e and λ, with a contribution of over 20%; (4) cathode position and cathode size had no statistically significant effect on the hydraulic performance of CW–MFCs. It was mainly through the blocking of water flows, flows around, compressing water flow channels and boundary layer separation that the MFC electrodes influenced the hydraulic characteristics of the flow field in CW–MFCs. Optimizing the flow field by optimizing the electrode configuration helped to facilitate electricity generation and pollutants’ removal in CW–MFCs. This study offers a scientific reference for improving the hydraulic performance of CW–MFCs, and it also provides a new research perspective for improving the wastewater treatment and electricity production performance of CW–MFCs.