Background: We aimed to assess the effectiveness and safety of transcatheter arterial embolization (TAE) in the management of spontaneous or traumatic psoas and/or retroperitoneal hemorrhage. Methods: This single-center retrospective study enrolled 36 patients who underwent TAE for the treatment of psoas and/or retroperitoneal hemorrhage between May 2016 and February 2024. Results: The patients’ mean age was 61.3 years. The spontaneous group (SG, 47.1%) showed higher rates of anticoagulation therapy use compared with the trauma group (TG, 15.8%) (p = 0.042). The TG (94.7%) demonstrated higher survival rates compared with the SG (64.7%; p = 0.023). Clinical failure was significantly associated with the liver cirrhosis (p = 0.001), prothrombin time (p = 0.004), and international normalized ratio (p = 0.007) in SG and pRBC transfusion (p = 0.008) in TG. Liver cirrhosis (OR (95% CI): 55.055 (2.439–1242.650), p = 0.012) was the only identified independent risk factor for primary clinical failure in the multivariate logistic regression analysis. Conclusions: TAE was a safe and effective treatment for psoas and/or retroperitoneal hemorrhage, regardless of the cause of bleeding. However, liver cirrhosis or the need for massive transfusion due to hemorrhage increased the risk of clinical failure and mortality, necessitating aggressive monitoring and treatment.
1 January 2025 in Journal of the Belgian Society of Radiology
Background: We assess the clinical outcomes and utility of cone‑beam computed tomography (CBCT) during transcatheter arterial embolization (TAE) in patients with malignant intractable hematuria, related to lower urinary tract malignancy.
The objective was to evaluate the incidence and degree of double-J ureteral stent (DJUS) migration. Additionally, we aimed to investigate the risk factors associated with stent migration in the orthotopic neobladder group. In this retrospective study, 61 consecutive patients were included; 35 patients (45 DJUS placements) underwent radical cystectomy with orthotopic neobladder and 26 patients (35 DJUS placements) underwent urinary bladder without cystectomy between July 2021 and March 2023. All the patients were treated with a DJUS for ureteric strictures. The technical success rate was 100% in each group. The DJUS migration was significantly higher in the orthotopic neobladder group, with 22 of 45 cases (48.9%), compared to the urinary bladder group, which had 4 of 35 cases (11.4%) (P ≤ .001). Among the patients in the orthotopic neobladder group who experienced DJUS migration, stent dysfunction occurred in 18 cases (81.8%), which was statistically significant (P = .003). Multivariate logistic regression analysis revealed that only the size of the DJUS was significantly and positively associated with migration (odds ratio:10.214, P = .010). DJUS migration can easily occur in patients undergoing radical cystectomy and orthotopic neobladder, and smaller stent sizes are associated with a higher incidence of migration.
We aimed to investigate the risk factors of early double-J ureteral stent (DJUS) dysfunction rates and the long-term patency of DJUSs inserted via a percutaneous approach in patients with benign uretero-ileal anastomosis stricture (UIAS) who had undergone radical cystectomy. In this retrospective study, 63 DJUS placements were placed via a percutaneous nephrostomy tract in 42 consecutive patients between May 2020 and March 2023. The technical success rate was 100% in all patients without major complications. The early dysfunction rate and long-term patency rate were 38.1% (24/63) and 84.2% (32/38), respectively. The blood clot retention grade, balloon dilatation, and length of the ureteral stricture exhibited a significant correlation with early DJUS dysfunction (blood clot retention grade: odds ratio (OR) 6.922 in grade two, p = 0.009; balloon dilatation: OR 0.186, p = 0.017; length of ureteral stricture: OR 8.715, p = 0.035 in moderate stenosis, and 7.646, p = 0.028 in severe stenosis). A multivariate Cox’s proportional hazard analysis revealed that blood clot retention grade and length of ureteral stricture were independent predictors of long-term DJUS patency. Percutaneous insertion of the DJUSs was safe and effective in patients with benign UIAS.
Background: We aimed to compared radiation exposure and image quality between tin-filter-based and standard dose thoraco-abdominal computed tomography angiography (TACTA) protocols, aiming to address a gap in the existing literature. Methods: In this retrospective study, ninety consecutive patients undergoing TACTA were included. Of these, 45 followed a routine standard-dose protocol (ST100kV), and 45 underwent a low-dose protocol with a tin filter (TF100kV). Radiation metrics were compared. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) were calculated for the thoracic and abdominal aorta and right common iliac artery. Two independent readers assessed the image noise, image contrast, sharpness, and subjective image quality. Results: The mean dose for the TF100kV group was significantly lower (DLP 128.25 ± 18.18 mGy*cm vs. 662.75 ± 181.29, p < 0.001; CTDIvol 1.83 ± 0.25 mGy vs. 9.28 ± 2.17, p = 0.001), with an effective dose close to 2.3 mSv (2.31 ± 0.33 mSv; p < 0.001). The TF100kV group demonstrated greater dose efficiency (FOM, thoracic aorta: 36.70 ± 22.77 vs. 13.96 ± 13.18 mSv−1, p < 0.001) compared to the ST100kV group. Conclusions: Dedicated low-dose TACTA using a tin filter can significantly reduce the radiation dose while maintaining sufficient diagnostic image quality.