Fredy David Bernal Castillo

Mr. Fredy David Bernal Castillo

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in TECCIENCIA
Verified
Journal Article
Open access
FCFredy David Bernal Castillo
Fredy David Bernal Castillo
GRGuillermo Roa Rodríguez
Guillermo Roa Rodríguez
CCCarlos Cabrera Cabrera
Carlos Cabrera Cabrera
NMNicolás Sierra Melo
Nicolás Sierra Melo
WAWilliam Aperador
William Aperador
In this paper, we present the design and construction of a remote monitoring system for determining the probability and rate of corrosion of rebar embedded in concrete. We use the ASTM standard C876 technique for the probability of corrosion and the Linear Polarization Resistance method to indirectly obtain the rate of corrosion. The system consists of a communication module using GSM and GPRS cellular networks which provide remote measurements. The device was used to evaluate corrosion with reference electrodes of copper/copper sulfate and graphite on Type I Portland cement specimens of 15cm in diameter and 30cm in length. The results of the measurements were compared to a commercial system, revealing similar values to the data obtained in the field and the laboratory.

1 December 2016 in MRS Proceedings
Verified
Journal Article
Closed access
PDF file
FCFredy David Bernal Castillo
Fredy David Bernal Castillo
WAW. Aperador
W. Aperador
GRG. Roa-Rodríguez
G. Roa-Rodríguez

30 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
FCFredy David Bernal Castillo
Fredy David Bernal Castillo
VFVeronique Feipel
Veronique Feipel
MPMauricio Plaza
Mauricio Plaza
As part of an investigation to detect asymmetries in gait patterns in persons with shoulder injuries, the goal of the present study was to design and validate a Kinect-based motion capture system that would enable the extraction of joint kinematics curves during gait and to compare them with the data obtained through a commercial motion capture system. The study included eight male and two female participants, all diagnosed with anterolateral shoulder pain syndrome in their right upper extremity with a minimum 18 months of disorder evolution. The participants had an average age of 31.8 ± 9.8 years, a height of 173 ± 18 cm, and a weight of 81 ± 15 kg. The gait kinematics were sampled simultaneously with the new system and the Clinical 3DMA system. Shoulder, elbow, hip, and knee kinematics were compared between systems for the pathological and non-pathological sides using repeated measures ANOVA and 1D statistical parametric mapping. For most variables, no significant difference was found between systems. Evidence of a significant difference between the newly developed system and the commercial system was found for knee flexion–extension (p < 0.004, between 60 and 80% of the gait cycle), and for shoulder abduction–adduction. The good concurrent validity of the new Kinect-based motion analysis system found in this study opens promising perspectives for clinical motion tracking using an affordable and simple system.

21 December 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
ITIng. Mauricio Plaza Torres
Ing. Mauricio Plaza Torres
FCFredy David Bernal Castillo
Fredy David Bernal Castillo
ICIng. Andrés Cifuentes
Ing. Andrés Cifuentes
This paper presents a discussion about the design a novel exoskeleton and the implementation of superficial magnetic sensor and pressure sensor for find patterns and parameters in order to predicting the intention of movement for people with musculoskeletal system problem in lower limbs. The information is obtained through reading position and movement by magnetic and pressure sensor installed in different parts of the body. The advantage of this sensor is the location of the position reference of the every part of the body. Using the sensor in some parts of the body is possible to calculate the muscle contraction for the prediction of intended movement and to find a new design with light and comfortable materials.