Most studies on Chinese dormitories are carried out in summer, while few focus on a transition season or winter. This study evaluated the air quality of a student dormitory in a university in the Beijing area by using a questionnaire survey and on-site measurements. The CO2 concentration was used as an indoor air quality evaluation index to characterize the freshness of the air, and different window opening conditions in the dormitory were simulated, with corresponding improvement plans proposed. The results of this study revealed that the air quality and thermal comfort of the student dormitories during a transition season and winter fell short of expectations. According to the survey, students who opened their windows frequently had a better subjective perception of the air quality. However, due to the large temperature difference between day and night, more than 80% of the students felt too cold when opening the windows. For daytime conditions, the area of unilateral ventilation window opening should not be less than 0.39 m2, the area of bilateral ventilation window opening should not be less than 0.13 m2, and the time taken to close the windows and doors should not exceed the maximum ventilation interval. Empirical equations were fitted for nighttime conditions based on the CO2 concentration, number of people in the room, and window opening area, resulting in a reasonable window opening area of 0.349 m2~0.457 m2. In sum, this study assessed the air quality status within typical university dormitories across varying seasons, gaining a clear understanding of how different ventilation strategies and occupant densities influence air freshness and thermal comfort. Based on these insights, a practical and optimized window area recommendation was formulated to enhance the indoor environmental quality in these dormitories.
The daylighting environment in university gymnasiums affects daily teaching and sports training. However, direct sunlight, glare, and indoor overheating in summer are common problems. Semi-transparent photovoltaic glass can solve these issues by replacing shading facilities, blocking solar radiation, and generating electricity. This study examines the influence of different types of CdTe semi-transparent film photovoltaic glass on the daylighting environment of six typical university gymnasium skylights. The optimal types of CdTe semi-transparent film photovoltaic glass are determined by dynamic daylighting performance metrics DA, DAcon, DAmax, and UDI. The results show that, for instance, centralized rectangular skylights benefit from the 50–60% transmittance type, while centralized X-shaped skylights require the 70–80% transmittance type to enhance indoor daylighting. The research results offer specific recommendations based on skylight shapes and photovoltaic glass types and can provide a reference for the daylighting design of university gymnasium buildings with different forms of photovoltaic skylights in the future.
Artificial lighting comprises nearly one-third of the total electrical load of buildings, resulting in significant carbon emissions. Reducing the carbon emissions caused by artificial lighting is one of the ways to achieve low-carbon buildings. To meet the demand for high-efficiency, energy-saving, and comfortable lighting, light pipes are increasingly used in buildings. This paper reviews the research and development of light pipes and integrated technology. Sky conditions as a dynamic factor always affect the performance of light pipes. The combination of light pipes and an artificial lighting system can effectively solve this problem. A light pipe can be integrated with a ventilation stack to achieve the ventilation and cooling or heating of a building. A lighting-heating coupled light guide can improve the energy efficiency and sustainability in buildings, such as where antimony tin oxide nanofluid is introduced to absorb additional heat and then provide domestic hot water. The application of a photocatalyst to light pipes can realize air purification and self-cleaning. The use of light pipes does not consume electricity and can reduce the time spent using artificial lighting, thus allowing for power savings. From a whole life cycle perspective, the use of light pipes can be a balance of cost and benefit. In conclusion, such information could be useful for engineers, researchers, and designers to assess the suitability of applying integrated light pipes in different building types and examine the potential of energy and cost savings.
Taking the high and large space of the University of Science and Technology Beijing Gymnasium as this research object, this paper analyzes the influence of different window positions, window-to-wall ratio (WWR), solar heat gain coefficient (SHGC), heat transfer coefficient (K), and visible light transmittance (VT) on the total indoor energy consumption in winter and summer and obtains the relationship between the daylight factor and VT formed when the window is opened per unit area. Through energy consumption simulation, the variation law and calculation formula for indoor total energy consumption are obtained. The results show that the SHGC and K of the exterior window have a significant influence on the total energy consumption. By using the energy consumption simulation of different types of exterior windows, it is concluded that the SHGC of the south-facing window is negatively correlated with the variation of air conditioning energy consumption per unit area Δe1,w, while the others are positively correlated. Moreover, the SHGC and K of the skylight have the most significant influence on the Δe1,w. The total energy consumption decreases and then increases with the increase in the window area, and there is a lowest point, so the right side of the lowest point is less than or equal to 105% of the lowest total energy consumption as a reasonable window area zone. Finally, a progressive optimization method for weighing daylighting and energy consumption in university gymnasiums in Beijing is proposed.
The lighting design of large-space buildings in gymnasiums can impact the indoor luminous and thermal environment, resulting in an uneven light and thermal distribution. This paper investigates the luminous and thermal environment control strategies for high spaces in gymnasiums, by simulating the luminous and thermal environment under different lighting forms and establishing a comprehensive evaluation model. The results show that the weights of the indoor luminous environment, thermal environment, and comprehensive energy consumption change with season and time under different lighting forms, which provides a basis for developing a temporal–spatial partition control strategy. The temporal–spatial partition control strategy is proposed for summer and winter, including the shading angle control under the lighting forms of south-facing side windows, west-facing side windows, and top skylights. Under summer conditions, the south-facing side windows have no shading from 8:00 to 10:00 and 14:00 to 16:00, and the shading angle is 0° from 10:00 to 14:00; the west-facing side windows have no shading from 8:00 to 14:00, the shading angle is 0° from 14:00 to 15:00, and the shading angle is 15° from 15:00 to 16:00; and the top skylight has a shade angle of 15° from 8:00 to 9:00, 30° from 9:00 to 11:00, 45° from 11:00 to 13:00, and no shade from 13:00 to 16:00. Under winter conditions, the south-facing side windows have no shading all day; the west-facing side windows have no shading from 8:00 to 14:00, and the shading angle is 30° from 14:00 to 16:00; and the top skylight has no shading from 8:00 to 13:00, a shading angle of 45° from 13:00 to 15:00, and a shading angle of 75° from 15:00 to 16:00. This paper provides a set of scientific and reasonable luminous and thermal environment regulation strategies for large-space buildings, which can help optimize the building energy consumption and improve the indoor environment quality.
Due to the advantages of a short cycle, low investment and low energy consumption per ton of steel, short-process electric furnace steelmaking is about to welcome a golden period of rapid development in China. During the operation of the electric furnace, a large amount of smoke and dust is generated. Most studies focus on organized emissions, and the impact of unorganized emissions in workshops on the environment cannot be ignored. This paper evaluates the thermal environment in the electric furnace steelmaking workshop based on the analytic hierarchy process and obtains the influence weight of the fugitive emission location. The mass concentration of dust at each measuring point increased by 1.17 mg/m3 on average, and the concentration of unorganized emission dust near the outlet was 23.572 mg/m3. The numerical simulation calculation model is established by the CFD method, a fixed initial jet velocity is set, the initial velocity of the ladle soot plume is changed, and the inclination angle, arrangement height and dust removal air volume of the dust hood are respectively adjusted in different tapping periods. The impact of simulation on the efficiency of dust collection for different dust removal hood configurations was investigated, considering variations in inclination angle, arrangement height and dust removal airflow. The optimal structural parameters for the dust removal hood were determined to be an inclination angle of 60° and an arrangement height of 2.4 m, and an optimal dust removal airflow was determined to be 110,000 m3/h. This study provides a theoretical foundation for engineering practice.