Hujin Xie

Dr. Hujin Xie


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2024 in Journal of Biomechanics
Verified
Journal Article
Open access
HXHujin Xie
Hujin Xie
HYHan Yu
Han Yu
HWHao Wu
Hao Wu
Jiaqiu WangJiaqiu Wang
Jiaqiu Wang
SWShanglin Wu
Shanglin Wu
ZLZhiyong Li
Zhiyong Li
Recent studies have suggested that irregular pulsation of intracranial aneurysm during the cardiac cycle may be potentially associated with aneurysm rupture risk. However, there is a lack of quantification method for irregular pulsations. This study aims to quantify irregular pulsations by the displacement and strain distribution of the intracranial aneurysm surface during the cardiac cycle using four-dimensional CT angiographic image data. Four-dimensional CT angiography was performed in 8 patients. The image data of a cardiac cycle was divided into approximately 20 phases, and irregular pulsations were detected in four intracranial aneurysms by visual observation, and then the displacement and strain of the intracranial aneurysm was quantified using coherent point drift and finite element method. The displacement and strain were compared between aneurysms with irregular and normal pulsations in two different ways (total and stepwise). The stepwise first principal strain was significantly higher in aneurysms with irregular than normal pulsations (0.20±0.01 vs 0.16±0.02, p=0.033). It was found that the irregular pulsations in intracranial aneurysms usually occur during the consecutive ascending or descending phase of volume changes during the cardiac cycle. In addition, no statistically significant difference was found in the aneurysm volume changes over the cardiac cycle between the two groups. Our method can successfully quantify the displacement and strain changes in the intracranial aneurysm during the cardiac cycle, which may be proven to be a useful tool to quantify intracranial aneurysm deformability and aid in aneurysm rupture risk assessment.

27 September 2025 in Journal of Biomechanics
Verified
Journal Article
Open access
HYHan Yu
Han Yu
HXHujin Xie
Hujin Xie
ZWZidun Wang
Zidun Wang
HWHao Wu
Hao Wu
ANArnold Ng
Arnold Ng
ZLZhiyong Li
Zhiyong Li
Patients with atrial fibrillation (AF) are at risk for cardioembolic stroke. The recent studies suggest that reduced two-dimensional left atrial (LA) deformation, such as longitudinal strain, may be a potential indicator of stroke risk. We aim to evaluate three-dimensional (3-D) LA global and local strain derived from four-dimensional computed tomography angiography in patients with persistent atrial fibrillation, and compare those with and without cardioembolic stroke history. 22 patients with persistent atrial fibrillation (11 with documented cardioembolic stroke) were included in this study. The LA strain was calculated by our novel mesh-regularised sub-volume tracking method. LA morphology, CHADS-VASC2, and 3-D global and local strain in 8 LA regions (anterior, lateral, appendage, roof, posterior, mitral isthmus, floor, and septum) were analysed. To explore the potential performance of the collected parameters for stroke risk evaluation, we used logistic regression to assess the outcomes of using these parameters to identify patients with cardioembolic stroke. Compared to those without previous stroke events, the patients with cardioembolic stroke presented lower global strain (0.090 vs 0.101; p = 0.006). Patients with cardioembolic stroke also had lower strain values in the roof (0.087 vs 0.106, p = 0.030), posterior (0.055 vs 0.072, p < 0.001) and floor (0.083 vs 0.097, p = 0.022). Results from logistic regression indicated that the accuracy of LA posterior strain as the indicator for previous stroke events was 0.8958. Therefore, 3-D LA global and local strain (especially in the posterior wall) could be useful in identifying patients with persistent AF and at high risk for a cardioembolic stroke.

4 October 2024 in Journal of Biomechanics
Verified
Journal Article
Open access
HYHan Yu
Han Yu
ZWZidun Wang
Zidun Wang
HWHao Wu
Hao Wu
ZZZhengduo Zhu
Zhengduo Zhu
Jiaqiu WangJiaqiu Wang
Jiaqiu Wang
ZLZhiyong Li
Zhiyong Li
Atrial strain and motion play important roles in evaluation of stroke risks for patients with atrial fibrillation. While cardiac computed tomographic angiography (CTA) provides detailed left atrial morphology with unparallel image resolution, finding a suitable strain measurement method for CTA remains a considerable challenge. In this paper, for the first time, we introduced a mesh regularized image block matching method to estimate 3D left atrial (LA) surface strain with 4D CTA. A series of performance tests with ex-vivo phantom and in-vivo 4D-CTA data were deployed. In conclusion, our proposed method could provide reliable LA motion and strain data within limited time.