Zhongjie Huan

Dr. Zhongjie Huan


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 July 2020 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
DEDaniel Raphael Ejike Ewim
Daniel Raphael Ejike Ewim
AAA. O. Adelaja
A. O. Adelaja
EOE. J. Onyiriuka
E. J. Onyiriuka
Josua MeyerJosua Meyer
Josua Meyer
ZHZhongjie Huan
Zhongjie Huan

31 May 2023 in Building and Environment
Verified
Journal Article
Open access
ANAsasei Unarine Casey Ndanduleni
Asasei Unarine Casey Ndanduleni
TRThandiwe Bongani Radebe
Thandiwe Bongani Radebe
ZHZhongjie Huan
Zhongjie Huan

29 July 2013 in International Journal of Green Energy
Verified
Journal Article
Open access
XWXi Wu
Xi Wu
ZYZhao Yang
Zhao Yang
HLHuanwei Liu
Huanwei Liu
ZHZhongjie Huan
Zhongjie Huan
WWWenbin Wang
Wenbin Wang
In the present article, a novel gas engine-driven heat pump (GEHP) which could independently provide heating, cooling, and hot water for the buildings with its autonomous power supply system was presented, and the cooling performance characteristics of GEHP using mixture refrigerant R134a/R152a were investigated experimentally. The thermophysical properties and flammability of this proposed mixture refrigerant were analyzed and experimented to approve that it could be used safely in GEHP. The experimental results indicated that the cooling capacity, waste heat recovered from cylinder jacket and exhaust gas, gas engine energy consumption, and compressor power increased with the increase of the gas engine speeds and evaporator water inlet flow rate, but changed in a small range with the increase of the evaporator water inlet temperature except cooling capacity. The generator power remained about 4.90 kW in different operating conditions. Furthermore, the coefficient of performance (COP) and the primary energy ratio (PER) of GEHP also increased with the increase of the evaporator water inlet flow rate and temperature, but decreased with the increase of gas engine speeds. Finally, maximum COP and PER with mixture refrigerant R134a/R152a has been estimated with 8.88 and 1.69 in the aforementioned conditions.The National Natural Science Foundation of China (Grant No. 51076112 and 51276124) and the Science and Technology Project of Tiajin City (Grant No. 12ZCDGGX49400).http://www.tandfonline.com/loi/ljge20hb2016Mechanical and Aeronautical Engineerin

16 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
PRPaxis Roque
Paxis Roque
DCDaniel Chowdhury
Daniel Chowdhury
ZHZhongjie Huan
Zhongjie Huan
District of Namaacha in Maputo Province of Mozambique presents a high wind potential, with an average wind speed of around 7.5 m/s and huge open fields that are favourable to the installation of wind farms. However, in order to make better use of the wind potential, it is necessary to evaluate the operating conditions of the turbines and guide the independent power producers (IPPs) on how to efficiently use wind power. The investigation of the wind farm operating conditions is justified by the fact that the implementation of wind power systems is quite expensive, and therefore, it is imperative to find alternatives to reduce power losses and improve energy production. Taking into account the power needs in Mozambique, this project applied hybrid optimisation of multiple energy resources (HOMER) to size the capacity of the wind farm and the number of turbines that guarantee an adequate supply of power. Moreover, considering the topographic conditions of the site and the operational parameters of the turbines, the system advisor model (SAM) was applied to evaluate the performance of the Vestas V82-1.65 horizontal axis turbines and the system’s power output as a result of the wake effect. For any wind farm, it is evident that wind turbines’ wake effects significantly reduce the performance of wind farms. The paper seeks to design and examine the proper layout for practical placements of wind generators. Firstly, a survey on the Namaacha’s electricity demand was carried out in order to obtain the district’s daily load profile required to size the wind farm’s capacity. Secondly, with the previous knowledge that the operation of wind farms is affected by wake losses, different wake effect models applied by SAM were examined and the Eddy–Viscosity model was selected to perform the analysis. Three distinct layouts result from SAM optimisation, and the best one is recommended for wind turbines installation for maximising wind to energy generation. Although it is understood that the wake effect occurs on any wind farm, it is observed that wake losses can be minimised through the proper design of the wind generators’ placement layout. Therefore, any wind farm project should, from its layout, examine the optimal wind farm arrangement, which will depend on the wind speed, wind direction, turbine hub height, and other topographical characteristics of the area. In that context, considering the topographic and climate features of Mozambique, the study brings novelty in the way wind farms should be placed in the district and wake losses minimised. The study is based on a real assumption that the project can be implemented in the district, and thus, considering the wind farm’s capacity, the district’s energy needs could be met. The optimal transversal and longitudinal distances between turbines recommended are 8Do and 10Do, respectively, arranged according to layout 1, with wake losses of about 1.7%, land utilisation of about 6.46 Km2, and power output estimated at 71.844 GWh per year.

19 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
PRPaxis Roque
Paxis Roque
DCDaniel Chowdhury
Daniel Chowdhury
ZHZhongjie Huan
Zhongjie Huan
With the energy crisis and the constant blackout in the Mozambique Power Company grid, the option of applying solar photovoltaic (PV) systems has been one of the most used alternatives in the neighborhoods of the Maputo region. However, inefficient power delivery caused by unproper sizing and installation of stand-alone solar PV systems has been contributing to the low utilization of solar energy potential in the Maputo region. The optimal sizing and installation of the solar PV system is addressed to evaluate the influence of installation and operation parameters on the power output of PV modules. In this topic, PV modules parameters such as cell temperature, the module’s slope and azimuth angles, the losses caused by excessive heating of the module cells, shadows and dust on the PV module and the cooling process at the back of the module are assessed in order to find out the consequence of inadequate installation and operation parameters of solar PV systems in the Maputo region. The proper sizing and installation of the stand-alone solar PV system is fundamental to guarantee the continuous and efficient supply of power and, thus, different tools and techniques have been applied. This study will deal with the hybrid optimization of multiple energy resources (HOMER) and system advisor model (SAM), to size and improve power generation of solar PV systems. This study concluded that for the Maputo region, the optimal tilt angle is 23 ± 2° and the azimuth angle is 11 ± 2°. In addition, for optimization of the tilt and azimuth angles, it also examined the effect of module backside ventilation and proved that the system’s power generation increases with the rise of spacing between the module and the wall, since the strategy prevents the decline of the module cells efficiency. However, the maximum recommended spacing between the PV module and the mounting wall is about 0.4 m, since an effort to increase the spacing up to this level results in an insignificant growth of power output.