Jong Do Seo

Dr. Jong Do Seo

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Clinical and Applied Thrombosis/Hemostasis
Verified
Journal Article
Open access
PDF file
JSJong Do Seo
Jong Do Seo
JGJa-Yoon Gu
Ja-Yoon Gu
HJHye Soo Jung
Hye Soo Jung
YKYoon Jun Kim
Yoon Jun Kim
HKHyun Kyung Kim
Hyun Kyung Kim
Although portal vein thrombosis (PVT) commonly occurs in patients with hepatocellular carcinoma (HCC), the hypercoagulability mechanism in patients with HCC is not entirely clear. Recently, tumor-induced formation of neutrophil extracellular traps (NET) has been shown to trigger contact system activation, and contact system activation has been shown to be a new mechanism of thrombosis. Therefore, we investigated whether contact system activation and NET formation occurred in relation to PVT in HCC patients. The circulating levels of NET formation markers (DNA–histone complex, double-stranded DNA, neutrophil elastase) and contact system activation markers (factor XIIa and high-molecular-weight kininogen) were measured in 177 patients who had been diagnosed with HCC and 48 healthy controls. Presence of PVT was confirmed in 77 HCC patients. The levels of NET formation and contact system activation markers were significantly higher in patients than in healthy controls and they increased significantly with the increase in the model for end-stage liver disease (MELD) scores. Of note, these markers were significantly higher in HCC patients with PVT than in those without PVT. These NET formation markers and the contact system activation markers were significant thrombotic risk factors in HCC patients. The well-known liver injury markers (alanine transaminase, prothrombin time) significantly contributed to factor XIIa level. Contact system activation and NET formation are well correlated with liver disease severity and the markers of these can be used as thrombotic risk factors in HCC patients. In addition, therapeutics inhibiting the contact system can be potentially used to manage PVT in HCC patients.

1 March 2021 in Annals of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
JSJi Yeon Sung
Ji Yeon Sung
JSJong Do Seo
Jong Do Seo
DKDae-Hyun Ko
Dae-Hyun Ko
MPMin-Jeong Park
Min-Jeong Park
SHSang Mee Hwang
Sang Mee Hwang
PHPh.D.
Ph.D.
Ji Yeon Sung, M.D., Jong Do Seo, M.D., Dae-Hyun Ko, M.D., Min-Jeong Park, M.D., Sang Mee Hwang, M.D., Sohee Oh, Ph.D., Sail Chun, M.D., Moon-Woo Seong, M.D., Junghan Song, M.D., Sang Hoon Song, M.D., and Sung Sup Park, M.D.. Ann Lab Med 2021;41:155-70. https://doi.org/10.3343/alm.2021.41.2.155

11 December 2023 in Practical Laboratory Medicine
Verified
Journal Article
Open access
JLJoon Hee Lee
Joon Hee Lee
JSJong Do Seo
Jong Do Seo
KLKyunghoon Lee
Kyunghoon Lee
EREun Youn Roh
Eun Youn Roh
YYYeo-Min Yun
Yeo-Min Yun
JSJunghan Song
Junghan Song
Vitamin D (vit-D) deficiency is highly prevalent in the Korean population, highlighting the need for accurate measurements. In this study, the interferences by endogenous and cross-reactive substances were compared between routine vit-D immunoassays and mass spectrometry (MS) methods. Two MS methods and 4 immunoassays from different manufacturers (Abbott, Beckman Coulter, Roche, Siemens) were compared. Residual samples that were icteric, lipemic, hemolyzed, high in rheumatoid factor, from myeloma patients, or patients undergoing hemodialysis were collected. Also, 4 levels of National Institute of Standards and Technology (NIST) Standard Reference Material 972a, and 12 samples serially spiked with 3-epi-25-OH-D3 were prepared. Significant interferences were observed in hemolytic (Roche), icteric (Beckman and Siemens) and lipemic samples (all 4 immunoassays). Level 4 NIST material and 3-epi-25-OH-D3-spiked samples induced significant cross-reactivity, yielding higher total vit-D measurements in non-epimer-separating MS methods, and both the Beckman and Roche immunoassays. Most observed interferences were consistent with manufacturers’ claims, but overall improvement of immunoassay bias limits is required. Awareness of potential interference is important to increase the accuracy of vit-D measurements. Moreover, care is due when interpreting vit-D results of newborns, infants and less commonly, pregnant women, who are known to have physiologically high levels of the highly cross-reactive 3-epi-25-OH-D3.

25 May 2021 in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
Verified
Journal Article
Closed access
PDF file
SJSung Jin Jo
Sung Jin Jo
HCHyojin Chae
Hyojin Chae
YLYong-Wha Lee
Yong-Wha Lee
JSJong Do Seo
Jong Do Seo
Sanghoon SongSanghoon Song
Sanghoon Song
JLJehoon Lee
Jehoon Lee
Background: The type of blood collection tube affects specimen quality and laboratory results. Because plasma specimens have a shorter processing time compared with serum specimens, emergency biochemistry tests use plasma. However, serum specimens remain stable after centrifugation and show more accurate results than plasma. Therefore, a quick-clotting serum separator tube is expected to be useful for shorter turnaround times and accurate results. We evaluated a new quick-clotting serum separator tube VQ-Tube™ (AB Medical, Korea) for clinical chemistry and thyroid hormone assays. Methods: One hundred volunteers from four university hospitals were recruited, and peripheral blood samples were collected in quick-clotting serum separator tube VQ-Tubes™ and the commonly used serum separator tube V-Tubes™. The obtained specimens were used for 16 clinical chemistry assays and three thyroid hormone assays. Results: The differences (%) in the test results obtained from the samples in each tube satisfied the allowable difference ranges (19 assays). The differences in the test results between the tubes satisfied the desired specifications for accuracy except for the glucose results (2.75%). The paired t-test revealed significant differences between the results of six assays, but each set of results showed a good correlation. Samples were visually inspected for serum clarity and gel barrier integrity, and incomplete clotting reactions and haemolysed serum were not observed. Conclusions: The new quick-clotting VQ-Tube™ demonstrated reliable test results compared with the commonly used serum separator tube V-Tube™. This quick-clotting tube will provide fast test results with adequately separated serum specimens, especially for patients who need fast tests.

3 September 2025 in Annals of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
JSJong Do Seo
Jong Do Seo
GKGye Cheol Kwon
Gye Cheol Kwon
Jeong-Ho KIMJeong-Ho KIM
Jeong-Ho KIM
SLSang-Guk Lee
Sang-Guk Lee
JSJunghan Song
Junghan Song
YYYeo-Min Yun
Yeo-Min Yun
Jong Do Seo, M.D., Gye Cheol Kwon, M.D., Jeong-Ho Kim, M.D., Sang-Guk Lee, M.D., Junghan Song, M.D., Pil-Whan Park, M.D., Dongheui An, M.D., Qute Choi, M.D., Chan-Ik Cho, M.P.H., Sollip Kim, M.D., and Yeo-Min Yun, M.D.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2025.0010

9 August 2020 in Journal of Clinical Laboratory Analysis
Verified
Journal Article
Open access
PDF file
JLJoon Hee Lee
Joon Hee Lee
SKSungmin Kim
Sungmin Kim
SJSun‐Hee Jun
Sun‐Hee Jun
JSJong Do Seo
Jong Do Seo
YNYoungwon Nam
Youngwon Nam
JSJunghan Song
Junghan Song
Background: Hemoglobin A1c (HbA1c) is arguably the most important biomarker used in the diagnosis and treatment monitoring of diabetes mellitus. We evaluated the analytical performance of the Norudia HbA1c assay (Sekisui Medical Co., LTD), which uses an enzymatic method incorporated into a fully automated, high‐throughput system.Methods: The precision, linearity, and carryover of the Norudia HbA1c assay were evaluated. Using 60 patient samples, comparative analysis of HbA1c measurements with two commonly used HbA1c assays, the D100 (Bio‐Rad Laboratories, Inc) and HLC‐723 G11 (Tosoh), was undergone. Thirteen commutable samples with known HbA1c concentrations measured using an IFCC reference measurement procedure were used to compare accuracy between methods. Interference of HbA1c measurement by Hb variants was evaluated using 16 known Hb variant samples.Results: Repeatability (% CV) for low and high concentrations ranged from 1.12%‐1.50% and 0.66%‐0.75%, respectively, and within‐laboratory precision for low and high concentrations ranged from 1.73%‐2.89% and 0.98%‐1.64%, respectively. For linearity, the coefficient of determination was 0.9987. No significant carryover was observed. When compared to the D100 and HLC‐723 G11 assays, the Norudia HbA1c assay showed the best accuracy with the lowest mean bias (−1.72%). Furthermore, the Norudia was least affected by Hb variants and gave the most reliable HbA1c measurements.Conclusion: The Norudia HbA1c showed excellent analytical performance with good precision and linearity, and minimal carryover. When compared to other routine HbA1c methods, the Norudia HbA1c assay showed the highest accuracy and was least affected by Hb variants.