Elamir Abuabida Osman

Mr. Elamir Abuabida Osman


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2023 in Polymers
Verified
Journal Article
Open access
PDF file
MAMohamed Aboamer
Mohamed Aboamer
AAAhmed S. Alsuayri
Ahmed S. Alsuayri
AAAhmad Alassaf
Ahmad Alassaf
TATariq M. Alqahtani
Tariq M. Alqahtani
BABakheet A. Alresheedi
Bakheet A. Alresheedi
NMNader A. Rahman Mohamed
Nader A. Rahman Mohamed
This study explores the impact of disinfection techniques on the mechanical properties of poly(lactic acid) (PLA), a crucial material in the production of medical implants, tissue engineering, orthopedic devices and drug delivery systems, owing to its biocompatibility and ease of manufacturing. The focus is on evaluating the effectiveness of ultraviolet (UV) type C (254 nm wavelength) and the combined use of type C and B (310 nm wavelength) disinfection methods. Fifteen tensile test specimens (ASTM D638) and fifteen compression test specimens (ASTM D695) were utilized to assess PLA’s mechanical properties, including yield strength, ultimate strength, and fracture strength. The investigation involved subjecting the specimens to the specified disinfection methods and evaluating these properties both before and after the disinfection process. In the tensile test, a statistically significant difference (p = 0) in yield displacement was observed among the three groups. Additionally, a notable difference (p = 0.047) in fracture displacement was identified between the untreated group and the UVC and UVB combination group. No discernible impact on yield or fracture forces was noted. In the compression test, there was a significant difference (p = 0.04) in yield displacement and a clear difference (p = 0.05) in fracture force between the untreated group and the UVC and UVB combination group. The hybrid combination of UVC and UVB disinfection techniques did not affect yield force in both tensile and compression tests. However, it demonstrated a clear impact on displacement, suggesting its potential as a promising disinfection technique in the medical field.

1 March 2022 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
EMEmad Malaekah
Emad Malaekah
KAKhaled Al Awam
Khaled Al Awam
HShusham saied
husham saied
EOElamir Abuabida Osman
Elamir Abuabida Osman
VMVictor V. Mukhanov
Victor V. Mukhanov
HAHasan Alshagag
Hasan Alshagag
Mechanical ventilators are advanced life-supporting machines in this century. The ventilator needs to be safe, flexible, and easy for competent clinicians to use. Since ventilators supply the patient with gas, they need pneumatic components to be present. First technology ventilators were typically powered by pneumatic energy. Gas pressure is used to power ventilators as well as ventilate patients. Nowadays, ventilators are operated electronically with the useful microprocessor tool. This proposal aims to design a simple portable mechanical ventilator that includes measuring some important physiological variables such as respiratory rate, heart rate, and O2 saturation, which can be utilized in hospital and at home. The proposed system includes Arduino, Raspberry pi4, touch screen, and graphical user interface. This study showed a significant individual performance for measuring some important parameters such as flow rate, tidal volume, and minute ventilation. The accuracy of measuring the flow rate was 72%. The Cohen's kappa (CK) was estimated to be 0.61. The accuracy of calculated the tidal volume was estimated at 83% with 0.80 CK. The accuracy of measuring the O2 saturation was estimated at 99% with 0.99 CK. The advantages of the proposed design are cost-effective, safe, flexible, and easy to use. Also, this system is smart and can control its transactions, so it can be used at home without the need for professional help. The operating parameters can also be set by the user with a simple user interface.