Julio Raba

Prof. Dr. Julio Raba

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in Analytica Chimica Acta
Verified
Journal Article
Closed access
DRDaniel Matias Gaston Regiart
Daniel Matias Gaston Regiart
Martín A. Fernández BaldoMartín A. Fernández Baldo
Martín A. Fernández Baldo
Jhonny  Villarroel Rocha Jhonny Villarroel Rocha
Jhonny Villarroel Rocha
GMGermán A. Messina
Germán A. Messina
FBFranco Bertolino
Franco Bertolino
JRJulio Raba
Julio Raba

10 October 2011 in The Analyst
Verified
Journal Article
Closed access
PDF file
SPSirley V. Pereira
Sirley V. Pereira
FBFranco Bertolino
Franco Bertolino
Martín A. Fernández BaldoMartín A. Fernández Baldo
Martín A. Fernández Baldo
GMGermán A. Messina
Germán A. Messina
ESEloy Salinas
Eloy Salinas
JRJulio Raba
Julio Raba
In this article we report the development of an integrated microfluidic system coupled to a screen-printed carbon electrode (SPCE) applied to the quantitative determination of IgG specific antibodies present in serum samples of patients that suffer from Chagas disease. This relevant parasitic infection caused by the hemoflagellate protozoan Trypanosoma cruzi represents a major public health concern in Latin America. In order to perform the detection of mentioned antibodies, SPCE coupled to a microfluidic device was modified by electrodeposition of gold nanoparticles (AuNPs) and functionalized with Trypanosoma cruziproteins from epimastigote membranes. The developed microfluidic immunosensor with immobilized T. cruziproteins on the SPCE surface was successfully applied in the detection of specific IgG anti-T. cruziantibodies, which were allowed to react immunologically with immobilized T. cruziantigen. After that, labelled antibodies were quantified through the addition of horseradish peroxidase (HRP) enzyme-labeled secondary antibodies specific to human IgG, using 4-tert-butylcatechol (4-TBC) as enzymatic mediator. HRP in the presence of hydrogen peroxide (H2O2) catalyzes the oxidation of 4-TBC whose back electrochemical reduction was detected on a modified electrode at −100 mV. The calculated detection limit for electrochemical detection was 3.065 ng mL−1 and the intra- and inter-assay coefficients of variation were below 6.95%.

24 May 2011 in The Analyst
Verified
Journal Article
Closed access
PDF file
Martín A. Fernández BaldoMartín A. Fernández Baldo
Martín A. Fernández Baldo
FBFranco Bertolino
Franco Bertolino
GFGastón Fernández
Gastón Fernández
GMGermán A. Messina
Germán A. Messina
MSMaría I. Sanz
María I. Sanz
JRJulio Raba
Julio Raba
Ochratoxin A (OTA) is a mycotoxin produced by filamentous fungi of the genus Aspergillus and Penicillium that presents carcinogenic, teratogenic and nephrotoxic properties. In this work, we have developed, characterized and applied an immunoassay methodology comprised of magnetic nanoparticles (MNPs) as platform for immobilizing bioactive materials incorporated into a microfluidic system for rapid and sensitive quantification of Ochratoxin A (OTA) in apples (Red Delicious) contaminated with Aspergillus ochraceus. The sensor has the potential for automation and the detection of OTA was carried out using a competitive indirect immunoassay method based on the use of anti-OTA monoclonal antibodies immobilized on 3-aminopropyl-modified MNPs. The total assay time into the microfluidic competitive immunosensor was 16 min, and the calculated detection limit was 0.05 µg kg−1. Moreover, the intra- and inter-assay coefficients of variation were below 6.5%. The proposed method can be a very promising analytical tool for the determination of OTA in apparently healthy fruits post-harvest and for its application in the agricultural industry.

15 January 2010 in Journal of Chromatography B
Verified
Journal Article
Closed access
SPSirley V. Pereira
Sirley V. Pereira
GMGermán A. Messina
Germán A. Messina
JRJulio Raba
Julio Raba

28 March 2010 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
PSPatricia W. Stege
Patricia W. Stege
GMGermán A. Messina
Germán A. Messina
GBGuillermo Bianchi
Guillermo Bianchi
RORoberto A. Olsina
Roberto A. Olsina
JRJulio Raba
Julio Raba

1 July 2008 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
NMNoelia A. Martinez
Noelia A. Martinez
GMGermán A. Messina
Germán A. Messina
FBFranco Bertolino
Franco Bertolino
ESEloy Salinas
Eloy Salinas
JRJulio Raba
Julio Raba