Praveen Bansal

Dr. Praveen Bansal


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2021 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
PDF file
PBPraveen Bansal
Praveen Bansal
ASAlka Singh
Alka Singh

5 November 2021 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
PBPraveen Bansal
Praveen Bansal
ASAlka Singh
Alka Singh


10 January 2022 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
PBPraveen Bansal
Praveen Bansal
ASAlka Singh
Alka Singh

14 July 2026 in Turkish Journal of Electrical Engineering and Computer Sciences
Verified
Journal Article
Open access
PDF file
GYGaurav Yadav
Gaurav Yadav
SMSudhanshu Mittal
Sudhanshu Mittal
VKVineet Kumar
Vineet Kumar
SKSombir Kundu
Sombir Kundu
PBPraveen Bansal
Praveen Bansal
Dual-Quadrature Signal Generator (D-QSG) based Phase lock loop (PLL) has been recently proposed to handle the nonideal grid voltage conditions. However, selecting the parameter for D-QSG based controller has been a great challenge, especially for higher-order systems. Inappropriate parameter selection tends to increase settling time both in terms of amplitude as well as harmonics attenuation. Hence, in the proposed work, the main focus is on parameter selection to achieve a faster response. Here, a fourth-order Quasi-Synchronous Generator has been realized by cascading the two nonidentical second order generalized integrators (NISOGIs). Furthermore, the parameters of both the NISOGIs are selected in such a way that gives a faster envelope around the 2\% settling time threshold in 24.4 ms. This method provides a more condensed distance within a Fourth-Order transfer function's poles, which eventually results in a faster reaction time. A suggested method has been used to regulate an EV charger during harmonics and voltage sag/swell instead of interfering with regular operation. Furthermore, the EV charger can readily adjust the level of active and reactive power in accordance with the established benchmarks while compensating for load harmonics. Both MATLAB/Simulink and Real-time platform provided by OPAL-rt prove the effectiveness of this approach.

24 September 2025 in Smart Grids and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
ALAnuj Lodhi
Anuj Lodhi
PBPraveen Bansal
Praveen Bansal