Anika Strittmatter

Mrs. Anika Strittmatter

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2023 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Open access
ASAnika Strittmatter
Anika Strittmatter
LSLothar R. Schad
Lothar R. Schad
FZFrank G. Zöllner
Frank G. Zöllner
Multimodal image registration is applied in medical image analysis as it allows the integration of complementary data from multiple imaging modalities. In recent years, various neural network-based approaches for medical image registration have been presented in papers, but due to the use of different datasets, a fair comparison is not possible. In this research 20 different neural networks for an affine registration of medical images were implemented. The networks' performance and the networks' generalizability to new datasets were evaluated using two multimodal datasets - a synthetic and a real patient dataset - of three-dimensional CT and MR images of the liver. The networks were first trained semi-supervised using the synthetic dataset and then evaluated on the synthetic dataset and the unseen patient dataset. Afterwards, the networks were finetuned on the patient dataset and subsequently evaluated on the patient dataset. The networks were compared using our own developed CNN as benchmark and a conventional affine registration with SimpleElastix as baseline. Six networks improved the pre-registration Dice coefficient of the synthetic dataset significantly (p-value < 0.05) and nine networks improved the pre-registration Dice coefficient of the patient dataset significantly and are therefore able to generalize to the new datasets used in our experiments. Many different machine learning-based methods have been proposed for affine multimodal medical image registration, but few are generalizable to new data and applications. It is therefore necessary to conduct further research in order to develop medical image registration techniques that can be applied more widely.

11 June 2024 in IEEE Access
Verified
Journal Article
Open access
ASAnika Strittmatter
Anika Strittmatter
FZFrank G Zöllner
Frank G Zöllner
We proposed neural networks for deformable multimodal medical image registration that use multiple steps and varying resolutions. The networks were trained jointly in an unsupervised manner with Mutual Information and Gradient L2 loss. By comparing the multistep neural networks to each other and to a monostep/monoresolution network as a benchmark and the classical registration methods SimpleElastix and NiftyReg as a baseline, we investigated the impact of using multiple resolutions on the registration result. To assess the performance of the multistep networks, we used four three-dimensional multimodal datasets (a synthetic and an in-vivo liver dataset with CT and T1-weighted MR scans, an in-vivo kidney MR dataset with T1-weighted and T2-weighted MR scans and an in-vivo prostate MR dataset with T2-weighted and DWI MR scans). Experimental results showed that incorporating multiple steps and resolutions in a neural network leads to registration results with high structural similarity (NMI up to 0.33 ± 0.02, Dice up to 90.8 ± 3.1) and minimal image folding (|J| ≤ 0: less than 0.5%), resulting in a medically plausible transformation, while maintaining a low registration time (< 0.5 s). Moreover, our results demonstrate that spatial alignment improves with more resolutions/steps (up to 4 in this study), and multistep networks outperform monostage/monoresolution networks.

16 December 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ASAnika Strittmatter
Anika Strittmatter
ACAnna Caroli
Anna Caroli
FZFrank G Zöllner
Frank G Zöllner
Multimodal image registration is an important component of medical image processing, allowing the integration of complementary information from various imaging modalities to improve clinical applications like diagnosis and treatment planning. We proposed a novel multistage neural network for three-dimensional multimodal medical image registration, which addresses the challenge of larger rigid deformations commonly present in medical images due to variations in patient positioning in different scanners and rigid anatomical structures. This multistage network combines rigid, affine and deformable transformations in three stages. The network was trained unsupervised with Mutual Information and Gradient L2 loss. We compared the results of our proposed multistage network with a rigid-affine-deformable registration with the classical registration method NiftyReg as a baseline and a multistage network, which combines affine and deformable transformation, as a benchmark. To evaluate the performance of the proposed multistage network, we used four three-dimensional multimodal in vivo datasets: three renal MR datasets consisting of T1-weighted and T2-weighted MR scans and one liver dataset containing CT and T1-weighted MR scans. Experimental results showed that combining rigid, affine and deformable transformations in a multistage network leads to registration results with a high structural similarity, overlap of the corresponding structures (Dice: 76.7 ± 12.5, 61.1 ± 14.0, 64.8 ± 16.2, 68.1 ± 24.6 for the four datasets) and a low level of image folding (|J| ≤ 0: less than or equal to 1.1%), resulting in a medical plausible registration result.

22 March 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ASAnika Strittmatter
Anika Strittmatter
MWMeike Weis
Meike Weis
FZFrank G. Zöllner
Frank G. Zöllner
In four-dimensional time series such as dynamic contrast-enhanced (DCE) MRI, motion between individual time steps due to the patient’s breathing or movement leads to incorrect image analysis, e.g., when calculating perfusion. Image registration of the volumes of the individual time steps is necessary to improve the accuracy of the subsequent image analysis. Both groupwise and multiresolution registration methods have shown great potential for medical image registration. To combine the advantages of groupwise and multiresolution registration, we proposed a groupwise multiresolution network for deformable medical image registration. We applied our proposed method to the registration of DCE-MR images for the assessment of lung perfusion in patients with congenital diaphragmatic hernia. The networks were trained unsupervised with Mutual Information and Gradient L2 loss. We compared the groupwise networks with a pairwise deformable registration network and a published groupwise network as benchmarks and the classical registration method SimpleElastix as baseline using four-dimensional DCE-MR scans of patients after congenital diaphragmatic hernia repair. Experimental results showed that our groupwise network yields results with high spatial alignment (SSIM up to 0.953 ± 0.025 or 0.936 ± 0.028 respectively), medically plausible transformation with low image folding (|J| ≤ 0: 0.0 ± 0.0%), and a low registration time of less than 10 seconds for a four-dimensional DCE-MR scan with 50 time steps. Furthermore, our results demonstrate that image registration with the proposed groupwise network enhances the accuracy of medical image analysis by leading to more homogeneous perfusion maps.

15 December 2025 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
ZYZeyu Yang
Zeyu Yang
ZCZhilin Chen
Zhilin Chen
YSYipeng Sun
Yipeng Sun
ASAnika Strittmatter
Anika Strittmatter
ARAnish Raj
Anish Raj
FZFrank G Zöllner
Frank G Zöllner
Objective . We present seg2med (segmentation-to-medical images), a modular framework for anatomy-driven multimodal medical image synthesis. The system integrates three components to enable high-fidelity, cross-modality generation of computed tomography (CT) and magnetic resonance (MR) images based on structured anatomical priors. Approach . First, anatomical maps are independently derived from three sources: real patient data, extended cardiac-torso (XCAT) digital phantoms, and anatomies-synthetic subjects created by combining organs from multiple patients. Second, we introduce PhysioSynth, a modality-specific simulator that converts anatomical masks into imaging-like prior volumes using tissue-dependent parameters (e.g. HU, T 1, T 2, ρ ) and modality-specific signal models. It supports simulation of CT and multiple MR sequences, including gradient-echo, SPACE, and volumetric interpolated breath-hold examination. Third, the synthesized anatomical priors are used to train 2-channel conditional denoising diffusion probabilistic models, which take the anatomical prior as a structural condition alongside the noisy image, enabling it to generate high-quality, structurally aligned images within its modality. Main results . The framework achieves a structural similarity index measure (SSIM) of 0.94 ± 0.02 for CT and 0.82 ± 0.12 for MR images compared to real patient data, and 0.78 ± 0.04 FSIM for simulated CT from XCAT. The generative quality is further supported by a Fréchet inception distance of 20.20 for CT synthesis. In modality conversion tasks, seg2med attains SSIM scores of 0.91 ± 0.03 (MR → CT) and 0.77 ± 0.04 (CT → MR). Significance . In anatomical fidelity evaluation, synthetic CT images achieve a mean Dice coefficient exceeding 0.90 for 11 key abdominal organs, and over 0.80 for 34 of 59 total organs. These results underscore seg2med’s utility in cross-modality image synthesis, dataset augmentation, and anatomy-aware AI development in medical imaging.

20 February 2024
Verified
Book Chapter
Open access
PDF file
ASAnika Strittmatter
Anika Strittmatter
AHAlexander Hertel
Alexander Hertel
SDSteffen Diehl
Steffen Diehl
MFMatthias F. Froelich
Matthias F. Froelich
SSStefan O. Schoenberg
Stefan O. Schoenberg
FZFrank G. Zöllner
Frank G. Zöllner
Zusammenfassung The research project “Radiomics enhanced CT-guided targeted biopsy in lung cancer” utilises pre-calculated intratumoural heterogeneity areas to perform CT-guided biopsies of lung tumors. This involves the fusion of CT images acquired during preliminary examinations and their radiomics maps with biopsy CT images to detect potential intratumoral heterogeneity areas, requiring registration of the corresponding images. So, we developed a multistage registration approach with rigid preregistration. The dataset comprises 13 thorax CT volumes recorded during preliminary examinations (called CT images) and 13 narrowCT volumes (6 slices) acquired during biopsies (called biopsy CT images) of 13 patients with lung tumors. In some cases, due to the intervention, patients were lying on their side during the biopsy, whereas they were lying on their back during the preliminary examination. Rigid preregistration was initially performed to correct large rotations and translations. The rotation was determined using bounding boxes and ITK-Snap was used to estimate corresponding slices in the images. The preregistered CT images were then registered to the biopsy CT images using a SimpleElastix multistage algorithm, including rigid, affine, and deformable transformations. The transformations from the rigid preregistration and SimpleElastix were then applied to the radiomics maps. The results demonstrate that the multistage registration resulted in high structural similarity and overlap of lung tumors in the CT and biopsy CT images, enabling “virtual biopsies” and extraction of quantitative radiomics features of the exact puncture site [1].