Holly Gorin

Dr. Holly Gorin

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
HGHolly Gorin
Holly Gorin
JPJigna Patel
Jigna Patel
Qinyin QiuQinyin Qiu
Qinyin Qiu
AMAlma Merians
Alma Merians
Sergei AdamovichSergei Adamovich
Sergei Adamovich
GFGerard G Fluet
Gerard G Fluet
Gaze and pupil metrics are used to represent higher cognitive processes in a variety of contexts. One growing area of research is the real-time assessment of workload and corresponding effort in gamified or simulated cognitive and motor tasks, which will be reviewed in this paper. While some measurements are consistent across studies, others vary and are likely dependent on the nature of the effort required by the task and the resulting changes in arousal. Pupil diameter is shown to consistently increase with task effort and arousal; however, the valence of arousal must be considered. In many cases, measures of pupil diameter were sensitive to both excessive and insufficient challenge. Overall, it is evident that gaze and pupil metrics are valuable to assess the cognitive state during gamified and simulated tasks, and further research is indicated regarding their use in clinical populations in rehabilitation to inform optimally engaging interventions.

10 August 2023 in JMIR Medical Education
Verified
Journal Article
Open access
JDJudith Deutsch
Judith Deutsch
JPJohn L. Palmieri
John L. Palmieri
HGHolly Gorin
Holly Gorin
AWAugustus Wendell
Augustus Wendell
DWDonghee Yvette Wohn
Donghee Yvette Wohn
HDHarish Damodaran
Harish Damodaran
Background: The VSTEP Examination Suite is a collection of evidence-based standardized assessments for persons after stroke. It was developed by an interdisciplinary team in collaboration with clinician users. It consists of 5 standardized assessments: 2 performance-based tests using the Kinect camera (Microsoft Corp) to collect kinematics (5-Time Sit-to-Stand and 4-Square Test); 2 additional performance-based tests (10-Meter Walk Test and 6-Minute Walk Test); and 1 patient-reported outcome measure, the Activities-Specific Balance Confidence Scale. Objective: This study aimed to describe the development of the VSTEP Examination Suite and its evaluation as an educational tool by physical therapy students and faculty to determine its usefulness and usability. Methods: A total of 6 students from a Doctor of Physical Therapy program in the United States and 6 faculty members who teach standardized assessments in different physical therapy programs from the United States and Israel were recruited by convenience sampling to participate in the study. They interacted with the system using a talk-aloud procedure either in pairs or individually. The transcripts of the sessions were coded deductively (by 3 investigators) with a priori categories of usability and usefulness, and comments were labeled as negative or positive. The frequencies of the deductive themes of usefulness and usability were tested for differences between faculty and students using a Wilcoxon rank sum test. A second round of inductive coding was performed by 3 investigators guided by theories of technology adoption, clinical reasoning, and education. Results: The faculty members’ and students’ positive useful comments ranged from 83% (10/12) to 100%. There were no significant differences in usefulness comments between students and faculty. Regarding usability, faculty and students had the lowest frequency of positive comments for the 10-Meter Walk Test (5/10, 50%). Students also reported a high frequency of negative comments on the 4-Square Test (9/21, 43%). Students had a statistically significantly higher number of negative usability comments compared with faculty (W=5.7; P=.02), specifically for the 5-Time Sit-to-Stand (W=5.3; P=.02). Themes emerged related to variable knowledge about the standardized tests, value as a teaching and learning tool, technology being consistent with clinical reasoning in addition to ensuring reliability, expert-to-novice clinical reasoning (students), and usability. Conclusions: The VSTEP Examination Suite was found to be useful by both faculty and students. Reasons for perceived usefulness had some overlap, but there were also differences based on role and experience. Usability testing revealed opportunities for technology refinement. The development of the technology by interdisciplinary teams and testing with multiple types of users may increase adoption.

16 November 2022 in JMIR Preprints
Verified
Preprint
Open access
JDJudith Deutsch
Judith Deutsch
JPJohn L. Palmieri
John L. Palmieri
HGHolly Gorin
Holly Gorin
AWAugustus Wendell
Augustus Wendell
DWDonghee Yvette Wohn
Donghee Yvette Wohn
HDHarish Damodaran
Harish Damodaran
BACKGROUND The VSTEP Examination Suite is a collection of evidence-based standardized assessments for persons after stroke. It was developed by an interdisciplinary team in collaboration with clinician users. It consists of 5 standardized assessments: 2 performance-based tests using the Kinect camera (Microsoft Corp) to collect kinematics (5-Time Sit-to-Stand and 4-Square Test); 2 additional performance-based tests (10-Meter Walk Test and 6-Minute Walk Test); and 1 patient-reported outcome measure, the Activities-Specific Balance Confidence Scale. OBJECTIVE This study aimed to describe the development of the VSTEP Examination Suite and its evaluation as an educational tool by physical therapy students and faculty to determine its usefulness and usability. METHODS A total of 6 students from a Doctor of Physical Therapy program in the United States and 6 faculty members who teach standardized assessments in different physical therapy programs from the United States and Israel were recruited by convenience sampling to participate in the study. They interacted with the system using a talk-aloud procedure either in pairs or individually. The transcripts of the sessions were coded deductively (by 3 investigators) with a priori categories of usability and usefulness, and comments were labeled as negative or positive. The frequencies of the deductive themes of usefulness and usability were tested for differences between faculty and students using a Wilcoxon rank sum test. A second round of inductive coding was performed by 3 investigators guided by theories of technology adoption, clinical reasoning, and education. RESULTS The faculty members’ and students’ positive useful comments ranged from 83% (10/12) to 100%. There were no significant differences in usefulness comments between students and faculty. Regarding usability, faculty and students had the lowest frequency of positive comments for the 10-Meter Walk Test (5/10, 50%). Students also reported a high frequency of negative comments on the 4-Square Test (9/21, 43%). Students had a statistically significantly higher number of negative usability comments compared with faculty (W=5.7; P=.02), specifically for the 5-Time Sit-to-Stand (W=5.3; P=.02). Themes emerged related to variable knowledge about the standardized tests, value as a teaching and learning tool, technology being consistent with clinical reasoning in addition to ensuring reliability, expert-to-novice clinical reasoning (students), and usability. CONCLUSIONS The VSTEP Examination Suite was found to be useful by both faculty and students. Reasons for perceived usefulness had some overlap, but there were also differences based on role and experience. Usability testing revealed opportunities for technology refinement. The development of the technology by interdisciplinary teams and testing with multiple types of users may increase adoption.

3 September 2026 in Sensors
Verified
Journal Article
Open access
PDF file
JGJennifer Gutterman
Jennifer Gutterman
GFGerard G Fluet
Gerard G Fluet
Qinyin QiuQinyin Qiu
Qinyin Qiu
JPJigna Patel
Jigna Patel
HGHolly Gorin
Holly Gorin
Sergei AdamovichSergei Adamovich
Sergei Adamovich
Stroke often causes persistent upper extremity (UE) motor deficits, affecting reaching and grasping and impacting daily activities. Recovery may depend on whether the dominant or non-dominant hand is affected, a distinction that remains understudied. This pilot study aimed to characterize longitudinal UE recovery post-stroke. Twenty participants post-stroke (ten with the dominant hand affected, ten with the non-dominant hand affected) performed reach-to-grasp-and-lift tasks (1-inch cube, 2.5-inch circular object), plus clinical assessments, five times over six months with the initial testing around 15 days post-stroke (mean = 14.9). Kinematic measurements included Time to Peak Velocity, Time After Peak Velocity, Reach Duration, Reaching Trajectory Smoothness, Path Linearity, and Grasp Duration. Piecewise linear mixed-effects models evaluated longitudinal trends. Clinical measures improved significantly within 45 days post-stroke, while most kinematics improved significantly in the first 30 days but plateaued thereafter. A secondary exploratory analysis examining effects of hand dominance on UE recovery showed significant clinical improvements in both groups, but significant kinematic improvements were only demonstrated in the affected dominant hand group. Findings suggest kinematic improvements may be driven by dominant hand impairment, possibly reflecting motor control differences or greater reliance on the dominant hand. These results highlight the need for targeted rehabilitation strategies tailored to the non-dominant hand’s functional role.