Larissa L. Cunha

Ms. Larissa L. Cunha

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2022 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
RNRenna Nouwairi
Renna Nouwairi
LCLarissa L. Cunha
Larissa L. Cunha
RTRachelle Turiello
Rachelle Turiello
OSOrion Scott
Orion Scott
JHJeff Hickey
Jeff Hickey
JLJames P. Landers
James P. Landers
The polymerase chain reaction (PCR) is paramount in nucleic acid amplification testing, and for many assays, the use of PCR or qPCR is considered the ‘gold standard’. While instrumentation for executing PCR has advanced over the last two decades, a growing interest in point-of-need testing has highlighted the deficit that exists for ‘rapid PCR’ systems. Here, we describe a field-forward prototype instrument capable of ultra-fast thermal cycling for real-time PCR amplification of DNA and RNA. The custom-designed, injection-molded microfluidic chips interface with a novel mechatronic system to complete 40 cycles of real-time PCR in under 10 minutes, an 84% reduction in time compared to a standard 50 minute assay. Such rapid amplification is enabled by two thermoelectric Peltiers capable of efficiently heating and cooling the sample at 12 and 10 °C s−1, respectively. Judicious selection and strategic placement of the thermal cyclers and fluorescence detector relative to the microchip enable synchronized thermal cycling and fluorescence monitoring, further reducing time-to-result. Robust amplification and detection of DNA and RNA targets empowers laboratories to achieve rapid, actionable information in endless applications.

20 January 2023 in Analytica Chimica Acta
Verified
Journal Article
Closed access
MWM. Shane Woolf
M. Shane Woolf
LCLarissa L. Cunha
Larissa L. Cunha
KHKevyn C. Hadley
Kevyn C. Hadley
RMRachel P. Moffett
Rachel P. Moffett
JLJames P. Landers
James P. Landers

6 June 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Jamila MarshallJamila Marshall
Jamila Marshall
RTRachelle A. Turiello
Rachelle A. Turiello
LCLarissa L. Cunha
Larissa L. Cunha
EFElla V. Frazier
Ella V. Frazier
JHJeff Hickey
Jeff Hickey
James P. LandersJames P. Landers
James P. Landers
As COVID-19 transmission control measures are gradually being lifted, a sensitive and rapid diagnostic method for large-scale screening could prove essential for monitoring population infection rates. However, many rapid workflows for SARS-CoV-2 detection and diagnosis are not amenable to the analysis of large-volume samples. Previously, our group demonstrated a technique for SARS-CoV-2 nanoparticle-facilitated enrichment and enzymatic lysis from clinical samples in under 10 min. Here, this sample preparation strategy was applied to pooled samples originating from nasopharyngeal (NP) swabs eluted in viral transport medium (VTM) and saliva samples diluted up to 1:100. This preparation method was coupled with conventional RT-PCR on gold-standard instrumentation for proof-of-concept. Additionally, real-time PCR analysis was conducted using an in-house, ultra-rapid real-time microfluidic instrument paired with an experimentally optimized rapid protocol. Following pooling and extraction from clinical samples, average cycle threshold (CT) values from resultant eluates generally increased as the pooling dilution factor increased; further, results from a double-blind study demonstrated 100% concordance with clinical values. In addition, preliminary data obtained from amplification of eluates prepared by this technique and analyzed using our portable, ultra-rapid real-time microfluidic PCR amplification instrument showed progress toward a streamlined method for rapid SARS-CoV-2 analysis from pooled samples.

2 December 2019 in Journal of Chemometrics
Verified
Journal Article
Closed access
PDF file
NRNilmini H. Ratnasena
Nilmini H. Ratnasena
DRDayla C. Rich
Dayla C. Rich
AAAlyssa M. Abraham
Alyssa M. Abraham
LCLarissa L. Cunha
Larissa L. Cunha
SMStephen L. Morgan
Stephen L. Morgan

14 February 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
TLTiffany Layne
Tiffany Layne
ASAnchi Scott
Anchi Scott
LCLarissa L. Cunha
Larissa L. Cunha
RTRachelle A. Turiello
Rachelle A. Turiello
James P. LandersJames P. Landers
James P. Landers
Isothermal amplification methods have become popular in research due to the simplicity of the technology needed to run the reactions. Specifically, loop-mediated isothermal amplification (LAMP) has been widely used for various applications since first reported in 2000. LAMP reactions are commonly monitored with the use of colorimetry. Although color changes associated with positive amplification are apparent to the naked eye, this detection method is subjective due to inherent differences in visual perception from person to person. The objectivity of the colorimetric detection method may be improved by programmed image capture over time with simultaneous heating. As such, the development of a novel, one-step, automated, and integrated analysis system capable of performing these tasks in parallel is detailed herein. The device is adaptable to multiple colorimetric dyes, cost-effective, 3D-printed for single-temperature convective heating, and features an easy-to-use LabVIEW software program developed for automated image analysis. The device was optimized and subsequently validated using four messenger-RNA targets and mock forensic samples. The performance of our device was determined to be comparable to that of a conventional thermal cycler and smartphone image analysis, respectively. Moreover, the outlined system is capable of objective colorimetric analysis, with exceptional throughput of up to 96 samples at once.