The weight of the primary mirror increases as the aperture of ground-based telescopes increases, making it more challenging to maintain the positional stability and surface accuracy of the solid primary mirror. Consequently, a 2 m lightweight silicon carbide (SiC) mirror and an optimization method were proposed in this study. The relationship between the gravitational deformation of the mirror and its thickness and number of supports was derived based on force analysis of the mirror; the thickness of the mirror and the appropriate number of supports were obtained as initial parameters for optimization. The back structure of the mirror was designed in a lotus pattern to improve its rigidity. Numerous structural parameters were classified into major and non-major parameters based on the results of a sensitivity analysis. The non-major and major structural parameters were optimized using a Latin hypercube design method and a non-dominated sorting genetic algorithm, respectively. The optimized 2 m lightweight SiC mirror had a mass of 119 kg and an areal density of 38.7 kg/m2. The surface figure error root-mean-square (RMS) in the vertical state of the optical axis and the first modal resonance of the mirror assembly calculated using finite element analysis were 11.3 nm and 76.5 Hz, respectively. Modal tests of the mirror assembly were conducted using the hammering method, achieving a maximum relative frequency error of 7.4% compared with the simulation results. The optimized 2 m SiC mirror was over 50% lighter than traditional passive Zerodur mirrors of the same size.
We propose a new secondary mirror support structure assisted by multi-robotics to improve the observation performance of vehicle-mobile telescope systems. A mathematical model of the displacement at the end of the robotic and the variation of telescope pitch angle is established, then the posture of the robotic is optimized by the Jacobian matrix iteration inverse kinematic problem method. Based on the new support structure, a high-order sensitivity matrix is proposed to establish the mapping relationship between the robotic misalignment and the Zernike coefficient, with the accuracy verified via the Monte Carlo method. The method of adjusting the secondary mirror to compensate the aberration caused by the primary mirror is proposed, and the relationship between the primary mirror surface error and the system error is established under different pitch angles before and after compensation. The experiment and simulation results showed that the adjustment calculated by the high-order sensitivity matrix method can effectively compensate for the misalignment caused by the robotics and the primary mirror surface error to a certain degree. After multiple iterations, the root mean square of the wavefront aberration was better than . This conclusion provides an engineering application reference value for the secondary mirror support and aberration correction technology of the vehicle telescope system.
Cassegrain telescopes with larger apertures suffer significant optical pupil shifting errors caused by gravity and temperature gradients. This study constructs an optical model of a large Cassegrain telescope and a method to calculate and compensate its shifting error. First, the optical structure is simplified by incorporating only the most relevant telescope components, and the system optics is modeled using ray tracing. A computer-aided mounting-based method for calculating the misalignment error of primary and secondary mirrors is proposed, with the spatial position change of secondary mirrors as the input. Next, a compensation method based on the coma-free point theory of the Cassegrain system is proposed, with the main mirror’s optical axis as the reference. Finally, using a 4 m aperture telescope as an example, the gravity- and thermal-deformation-induced shifting error is simulated. Based on this simulation, the secondary mirror position is adjusted using a secondary mirror-adjustment mechanism Hexapod platform to compensate for the misalignment error. Both gravity and temperature are major causes of shift in the pupil position, with a maximum shift of 18 mm. After compensation, this shift is controlled within 1 mm. The modeling method and the simulation process mentioned in this research can also be used in the other relevant fields.