Biomolecular abundance detection of fermentation microorganisms is significant for the accurate regulation of fermentation, which is conducive to reducing fermentation costs and improving the yield of target products. However, the development of an accurate analytical method for the detection of biomolecular abundance still faces important challenges. Herein, we present a non-invasive biomolecular abundance detection method based on Raman spectra combined with target extraction and multimodel fitting. The high gain of the eXtreme Gradient Boosting (XGBoost) algorithm was used to extract the characteristic Raman peaks of metabolically active proteins and nucleic acids within E. coli and yeast. The test accuracy for different culture times and cell cycles of E. coli was 94.4% and 98.2%, respectively. Simultaneously, the Gaussian multi-peak fitting algorithm was exploited to calculate peak intensity from mixed peaks, which can improve the accuracy of biomolecular abundance calculations. The accuracy of Gaussian multi-peak fitting was above 0.9, and the results of the analysis of variance (ANOVA) measurements for the lag phase, log phase, and stationary phase of E. coli growth demonstrated highly significant levels, indicating that the intracellular biomolecular abundance detection was consistent with the classical cell growth law. These results suggest the great potential of the combination of microbial intracellular abundance, Raman spectra analysis, target extraction, and multimodel fitting as a method for microbial fermentation engineering.
31 July 2024 in IEEE Transactions on Instrumentation and Measurement
Sub-visible particles are a major cause of adverse clinical infusion reactions and can lead to serious health problems. Raman spectroscopy is a rapid, non-destructive method for traceable detection of sub-visible particles; however, the pixel level spectral resolution limits the accuracy of existing micro-Raman spectrometers. Consequently, we propose a sub-pixel calibration strategy to improve the detection accuracy of micro-Raman spectrometers. Firstly, a combined light source with higher stability and uniformity is selected to improve the standard wavelength coverage of the CCD pixels and the stability of the calibration. Subsequently, a wavelet-based automatic peak localization method is designed to obtain the pixel-integer values of the peak points corresponding to the standard wavelengths. Based on the spectral distribution characteristics, we can obtain a sub-pixel value corresponding to the peak center of the wavelength by fitting the Gaussian spectral peak curve. Then, a higher resolution sub-pixel level calibration is achieved by establishing a mapping function between wavelengths and peak centers. We compare the standard sample detection shift accuracy and stability by using sub-pixel and pixel calibration. The sub-pixel level calibration reduces the accuracy error from 4.3 to 1.3 cm -1 and the stability error from 4.8 % to 2.4 % compared to the pixel level calibration, improving the micro-Raman performance indicator from Level III to Level II. Additionally, comparing the results of traceable detection of eight common injectable particles, the average similarity of micro-Raman using sub-pixel calibration was 96.6 %, which is 7.5 % higher than the matching accuracy of pixel calibration. These results demonstrate that the improved calibration of micro-Raman enables more accurate and stable detection of particles, meeting the requirements of high-accuracy engineering applications in particle traceable detection for pharmaceutical companies.
Efficient de-redundant colony picking is essential to accelerating strain screening in fermentation microbiology. Conventional random picking is inefficient, exhibits high redundancy, and often misses low-abundance but valuable strains. To address this, we present a high-efficiency de-redundant selection strategy based on colony Raman spectroscopy and a hybrid clustering algorithm. We directly acquire colony Raman spectra and combine the complementary strengths of k-means and hierarchical clustering (HCA) to achieve both balanced global partitioning and sensitivity to low-abundance taxa. Systematic application on pure colonies and complex plate settings shows that, by picking only 12–26% of colonies, the method attains 80–100% species coverage. Relative to manual random picking and image-based feature selection, picking efficiency increased by 116.8% and 44.5%, respectively, substantially shortening the screening cycle and reducing workload. Overall, Raman-guided hybrid clustering substantially reduces redundant picking and improves detection of low-abundance strains. It provides practical support for efficient strain discovery, library construction, and process optimization.