Sarah Mubarak Alkahtany

Dr. Sarah Mubarak Alkahtany

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in The Journal of Contemporary Dental Practice
Verified
Journal Article
Closed access
ZAZeeshan H Ahmad
Zeeshan H Ahmad
SASarah Mubarak Alkahtany
Sarah Mubarak Alkahtany
Sukumaran AnilSukumaran Anil
Sukumaran Anil
Aim: To evaluate and compare the cytotoxicity of various concentrations of sodium hypochlorite on immortalized human bone marrow mesenchymal stem cells (MSCs). Materials and methods: The 5.25 percent sodium hypochlorite (NaOCl) at concentrations of 0.5, 0.1, 0.025, 0.0125, and 0.005 mg/ml were used to assess the cytotoxic effect on MSCs. Immortalized human bone marrow mesenchymal stem cells (hTERT-MSCs) were exposed to NaOCl at 5 different concentrations. Cell viability was assessed by 3-(4, 5-dimethylthiazol- 2-yl)-2,5-diphenyltetrazolium bromide (MTT) and alamarBlue assays. The cell morphology changes were assessed with scanning electron microscopy (SEM) after exposure to 2, 4, and 24 hour incubation. The ethidium bromide/acridine orange (EB/ AO) fluorescent stain was applied to the cells in the 8-chamber slides after they were incubated with the testing agents for 2 and 4 hours to detect live and dead cells. The observations were quantitatively and qualitatively analyzed. Results: The cell viability study using MTT assay and AB assay showed significant reduction with varying concentration at 2 and 4 hours incubation period. The cell viability decreased with the higher percentage of NaOCl. The exposure time also revealed an inverse relation to the cell viability. The SEM analysis showed reduction in the number of cells and morphological alterations with 0.5 mg/ml at 2 and 4 hours compared to 0.025 mg/ml NaOCl. Destruction of the cells with structural alterations and lysis was evident under fluorescence microscope when the cells were exposed to 0.5 mg/ml NaOCl. Conclusion: Within the limitations of this in vitro study it can be concluded that NaOCl is toxic to the human bone marrow MSCs. The cell lysis was evident with higher concentration of sodium hypochlorite. From the observations, it can be concluded that a lower concentration of NaOCl may be used as endodontic irrigant due to its cytotoxic properties. Further studies are man datory to evolve a consensus on the optimal concentration of sodium hypochlorite to be used as endodontic irrigant. How to cite this article: Alkahtani A, Alkahtany SM, Anil S. An in vitro Evaluation of the Cytotoxicity of Varying Concentrations of Sodium Hypochlorite on Human Mesenchymal Stem Cells. J Contemp Dent Pract 2014;15(4):473-481.

29 March 2014 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
AAAhmad AlKahtani
Ahmad AlKahtani
SASarah Mubarak Alkahtany
Sarah Mubarak Alkahtany
AMAmer Mahmood
Amer Mahmood
MEMona A Elsafadi
Mona A Elsafadi
AAAbdullah M Aldahmash
Abdullah M Aldahmash
Sukumaran AnilSukumaran Anil
Sukumaran Anil
Debridement and disinfection of the root canal system is a crucial step in endodontic procedures. The effectiveness of irrigation relies on both the mechanical flushing action and the ability of irrigants to dissolve tissue and kill bacteria. The objective of the present study is to evaluate and compare the cytotoxicity of QMix™ root canal irrigating solution on immortalized human bone marrow mesenchymal stem cells (hTERT-MSC-C1) and to compare it with that of sodium hypochlorite (NaOCl).

9 December 2022 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
SASarah Mubarak Alkahtany
Sarah Mubarak Alkahtany
FAFatemah Alrwais
Fatemah Alrwais
AAAsma Altamimi
Asma Altamimi
SBSundus Bukhary
Sundus Bukhary
AMAmani Mirdad
Amani Mirdad
Background: The radicular groove (RG) is one of the developmental anomalies that is commonly found in maxillary incisors. The formation of radicular groove is initiated around the cingulum and can reach the root at different levels. The incidence of radicular grooves was reported in different countries but there was no published data about the incidence of RG in Saudi Arabia. Therefore, this study aimed to evaluate the incidence of radicular grooves on maxillary lateral incisors in the Saudi population using cone-beam computed tomography (CBCT). Methods: The dental records of 490 patients (N = 490) with CBCT images of maxillary anterior teeth were screened for inclusion criteria. Then 264 included cases were evaluated independently by two Endodontists. The evaluation was performed on CBCT images in the axial, sagittal, and coronal sections using Planmeca Romexis® software. The following data were recorded for each patient: Patients’ age and gender, radicular groove presence or absence, and if it is bilateral or unilateral. The type of radicular groove was recorded according to Gu’s classification (type I, II, or III). Results: The incidence rate of radicular grooves in maxillary lateral incisors was 4.9%. RG was found to be unilateral in 61.5% and bilateral in 38.5%. The majority of RG were classified as type I in 69.2%, followed by type II in 15.4%, and type III was found in 15.4%. Conclusion: 4.9% of the Saudi population has RG in the upper lateral incisor. This anatomical variation is mostly present as type I on one side only (unilateral).

28 December 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SASarah Mubarak Alkahtany
Sarah Mubarak Alkahtany
AAAsma A. AlHussain
Asma A. AlHussain
HAHaifa A. AlMthen
Haifa A. AlMthen
HAHaya D. AlDokhi
Haya D. AlDokhi
SBSundus M. Bukhary
Sundus M. Bukhary
BABasma AlNeshmi
Basma AlNeshmi
This micro-computed tomography (micro-CT) analysis in vitro study was designed to compare void volume in root canal fillings performed using the single-cone (SC) technique and the continuous wave condensation (CWC) technique with bioceramic (BC) sealer. Forty human-extracted, single-rooted mandibular premolars were cleaned, shaped, and divided into two groups (n = 20) based on the obturation technique. In the first group, obturation was performed using the CWC technique with TotalFill HiFlow BC sealer. In the second group, obturation was performed using the SC technique with the conventional TotalFill BC sealer. All roots were scanned with micro-CT, and ©CTAn software version 1.20.8.0 was used to measure the void volume of each root third in all samples. Despite the different obturation techniques, both groups exhibited voids in filled root canals. The overall mean void volume in the SC group (0.253 ± 0.186) was significantly higher (p = 0.000) than that in the CWC group (0.035 ± 0.043). The difference was significant in the coronal (p = 0.000) and middle (p = 0.017) thirds. The CWC technique with TotalFill HiFlow BC sealer achieved superior obturation quality compared to the SC technique with conventional BC sealer in oval-shaped premolars.

8 April 2020 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
SASarah Mubarak Alkahtany
Sarah Mubarak Alkahtany
EAEbtissam Al-Madi
Ebtissam Al-Madi
Aim. To evaluate dentinal microcrack formation on root canals instrumented, continuously in the body temperature, with XP-endo shaper (XPES) and ProTaper Universal (PTU), by means of microcomputed tomographic (micro-CT) analysis. Methodology. Nineteen mesial roots with two separate canals (Vertucci Type IV) of extracted mandibular molars were used in this study. The root canals (N = 38) were divided into 2 groups. Group 1 (n = 19): all MB canals were instrumented with XPES. Group 2 (n = 19): all ML canals were instrumented with PTU. All roots were scanned with micro-CT before and after instrumentation. Two precalibrated examiners evaluated the cross-sectional images of each sample with DataViewer program. The dentinal microcracks (complete and incomplete) were counted in each third of the root for the preinstrumentation and the postinstrumentation images. Wilcoxin signed-rank and Mann–Whitney U tests were used for statistical analysis at a significance level of P<0.05. Results. The number of microcracks increased significantly (P<0.05) after instrumentation with XPES in the middle and cervical thirds. The number of microcracks increased significantly (P<0.05) after instrumentation with PTU in the cervical third only. There was no significant difference between the groups in the cervical and apical thirds. In the middle third, the XPES induced more incomplete microcracks than PTU (P<0.05). Conclusion. Within the limitations of this study, there was no significant difference in the dentinal microcrack formation between XPES and PTU in the apical and cervical thirds of the root. However, XPES instrumentation induced more incomplete microcracks than PTU in the middle third of human roots.

1 January 2024 in International Journal of Dentistry
Verified
Journal Article
Open access
SASarah Mubarak Alkahtany
Sarah Mubarak Alkahtany
RARana Alfadhel
Rana Alfadhel
AAAseel AlOmair
Aseel AlOmair
SDSarah Bin Durayhim
Sarah Bin Durayhim
Background: XP‐endo files are composed of Max‐Wire alloy, which was developed by FKG Dentaire (La Chaux‐de‐Fonds, Switzerland). This alloy, known as Martensite‐Austenite Electropolish Flex, is the first NiTi alloy used in endodontics to combine the shape memory effect with superelasticity for use in clinical practice.Objective: This article aims to provide a comprehensive overview of the existing knowledge and evidence regarding different XP‐endo files and systems, XP‐endo Finisher (XPEF), XP‐endo Shaper (XPES), XP‐endo Retreatment (XPER), XP‐endo Rise (XPE‐Rise), and XPE‐Rise Retreatment (XPE‐Rise‐R), to help clinicians understand their different properties and recommended clinical uses. Moreover, this review aims to identify future research opportunities in this field.Materials and Methods: A search was performed in the PubMed database using the keywords “XP endo” or “XP‐endo”. A total of 309 studies were identified during the initial search, and then initial abstract screening was conducted. The inclusion criteria included any study that aimed to evaluate XP endo files and systems on permanent teeth, either in vivo or in vitro. We excluded studies that were unrelated to the subject, literature reviews, case studies, and studies that employed deciduous teeth. Finally, we performed an extensive review of the selected 130 studies, which we assessed, summarized, and classified based on the specific XP‐endo file used.Conclusion: Overall, XP‐endo files offer significant improvements in endodontic treatment. XPEF excels in irrigation activation and medicament removal, and XPES succeeds in canal cleaning, shaping, and retreatment. The XPER system, which incorporates the XPEF‐R file, shows promise in removing root‐filling materials, but its performance is inconsistent compared to other retreatment systems. We have found limited information regarding the latest XPE‐Rise and XPE‐Rise‐R systems, additional research is required to fully determine their comparative effectiveness and optimize their clinical application.