Jiang Xu

Prof. Jiang Xu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2021 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MYMingyin Yao
Mingyin Yao
GFGangrong Fu
Gangrong Fu
JXJiang Xu
Jiang Xu
TLTao Li
Tao Li
LZLinying Zhang
Linying Zhang
HRHonghui Rao
Honghui Rao
Laser-induced breakdown spectroscopy (LIBS) is a promising alternative to conventional methods in classifying citrus huanglongbing (HLB). Mature citrus fruits with similar features were picked and divided into healthy and HLB-asymptomatic groups. LIBS spectra and images were collected by focusing a laser on fresh fruit surfaces without sample preparation. The pH value and soluble solids content of juice as the indicators of acidity and sugar were detected, and the content of Ca, Zn, and K in peel and pulp was analyzed. The characteristic lines from LIBS spectra were extracted by continuous wavelet transform and principal component analysis (PCA). The t -test of these indicators displayed significant difference between the two groups. Fisher discriminant analysis and multilayer perception neural network (MLP) were applied to identify the disease. The classification accuracy reached 100% by PCA-MLP. The results show that LIBS can realize in situ detection of citrus HLB fruits.

21 March 2022 in Applied Optics
Verified
Journal Article
Closed access
PDF file
GFGangrong Fu
Gangrong Fu
ZLZhongxiu Li
Zhongxiu Li
JXJiang Xu
Jiang Xu
WXWeiping Xie
Weiping Xie
PYPing Yang
Ping Yang
MYMingyin Yao
Mingyin Yao
To predict the nutrition and safety of agricultural products by laser-induced breakdown spectroscopy (LIBS), heavy metal Cd in rice was selected as an analytical target. Mature rice grain samples from 40 growing geographical areas around Poyang Lake were picked on-site and processed by grinding to obtain the edible rice. The content of Cd in rice samples was determined by graphite furnace atomic absorption spectrometry, and the rice pellets were detected by LIBS. The risk intake was estimated by the target hazard quotient and Chinese National Standard. Moreover, the samples were classified as clean, slight, and severe ones according to evaluation. The content of Cd was predicted by analyzing LIBS spectra coupled with the partial least square (PLS) model. The correlation coefficients ( R 2 ) reached 0.9036 and 0.9771 for the training and prediction sets, respectively, and the root mean square errors were 0.0487 and 0.027, respectively. It denotes that the PLS model has a higher prediction ability especially after LIBS spectra were processed by smoothing and multiplicative scatter correction. For the clean, slight, and severe rice samples, the LIBS intensity ratio between minerals Mg, K, Na, Si, and Mn to Ca was compared. The ratio was decreased in all samples as Cd stress increased. Correlation analysis results show that Mn displayed a highly significant negative correlation with Cd stress, while Mg, K, and Na displayed a significant negative correlation with Cd stress. The relationship between Si and Cd did not reach a significant level. This work indicated that it was feasible to use LIBS combined with a suitable data process to predict Cd content and the effect of Cd stress on minerals in rice. It is promising to evaluate the nutrition and safety of food products by analyzing LIBS spectra.

13 September 2023 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
JXJiang Xu
Jiang Xu
XWXiao Wang
Xiao Wang
MYMingyin Yao
Mingyin Yao
MLMuhua Liu
Muhua Liu
The intensity of the induced spectral signal is determined by the laser energy density.

2 December 2021 in Applied Optics
Verified
Journal Article
Closed access
PDF file
XWXiao Wang
Xiao Wang
MYMingyin Yao
Mingyin Yao
MZMin Zeng
Min Zeng
JXJiang Xu
Jiang Xu
In order to analyze the mechanism of plasma polarization characteristics and the improvement effect of spectral signal-to-back ratio, the intensity formulas of continuous spectrum and discrete spectrum were derived by exploring the path of the radiation spectrum. At the Brewster angle, the model of polarization degree was established based on the measured spectral data to identify the radiation intensity of plasma. The experimental results showed that the polarization characteristics of the background and discrete spectrum were both observed in the plasma spectrum of a copper element, and there were obvious differences in polarization degree and vibration direction. Moreover, cadmium and chromium were used to verify the detection model. It was found that the characteristic signals of the polarization spectrum were more than the effective peaks in laser-induced breakdown spectroscopy, and the variation trend was relatively gentle. The model retained the effective information in the continuum spectrum and fully explored the basic polarization mechanism of plasma. The measured data were not only convenient to observe the characteristic signal peaks of elements, but also greatly improved the recognition effect. This method could extract effective information of illumination plasma under the condition of low incident light intensity and reduce the damage of medium surface, which is a more effective nondestructive testing technology.

23 May 2022 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JXJiang Xu
Jiang Xu
XWXiao Wang
Xiao Wang
MYMingyin Yao
Mingyin Yao
MLMuhua Liu
Muhua Liu
Laser-induced breakdown spectroscopy (LIBS) is a fast recognition method for heavy-metal detection. The recognition rate of the characteristic spectrum is related to the laser-induced energy. In order to analyze the polarization characteristics of plasma and the improvement mechanism of recognition rate under the condition of low energy density, a detection model of polarization recognition rate was established by exploring the intensity formula of discrete spectral data. At the Brewster angle, the LIBS and discrete spectral data of Cd and Cu elements induced by five energies were measured in combination with the polarization spectrometric path. According to the model of polarization recognition rate, the optimization effect of the polarization separation approach on the plasma spectra of heavy-metal elements has been clarified, and the recognition rate of discrete spectra induced by low energy density has been improved. This study shows that the increase of laser energy is helpful to the recognition of characteristic spectral lines. Under the same energy induction, the polarization recognition rate of heavy-metal elements is larger, and this characteristic is more obvious under low energy density. This model not only improves the recognition rate of the plasma spectrum but also greatly reduces the requirement of laser energy and the damage of the medium surface, which is a more effective nondestructive testing technology.

10 June 2021 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JXJiang Xu
Jiang Xu
XWXiao Wang
Xiao Wang
MYMingyin Yao
Mingyin Yao
In order to obtain stable spectral data of copper plasma, a detection platform of polarization-resolved laser-induced breakdown spectroscopy (PRLIBS) was built. The PRLIBS characteristic function of copper was constructed by combining the spectral path of plasma discrete spectrum and contact spectrum. The system can not only measure the original data, but also obtain the polarization information in the spectral data. By analyzing the extraction method of spatial polarized light information, the characteristic model of S-wave intensity information in PRLIBS was derived. The results show that in the decay process of plasma energy, the anisotropy of plasma recombination under local thermal equilibrium makes the number of deflected particles of atoms and electrons different in unit time, which leads to the polarization of radiation. The polarization characteristics of the plasma spectrum decreased with the increase of laser energy density. The S-wave was very active, and the polarization of continuous media was much stronger than that of discrete line emission. The advantages were helpful to obtain more stable characteristic peak signals. As a plasma element identification method, PRLIBS makes up for the deficiency of plasma detection technology, and can provide a scientific basis for the safety and non-destructive detection of heavy metals.