Proton radiotherapy has the potential to provide state-of-the-art dose conformality in the tumor area, reducing possible adverse effects on surrounding organs at risk. However, uncertainties in the exact location of the proton Bragg peak inside the patient prevent this technique from achieving full clinical potential. In this context, in vivo verification of the range of protons in patients is key to reduce uncertainty margins. Protoacoustic range verification employs acoustic pressure waves generated by protons due to the radio-induced thermoacoustic effect to reconstruct the dose deposited in a patient during proton therapy. In this paper, we propose to use the a priori knowledge of the shape of the proton dose distribution to create a dictionary with the expected ultrasonic signals at predetermined detector locations. Using this dictionary, the reconstruction of deposited dose is performed by matching pre-calculated dictionary acoustic signals with data acquired online during treatment.
Lung ultrasound (LUS) allows for the detection of a series of manifestations of COVID-19, such as B-lines and consolidations. The objective of this work was to study the inter-rater reliability (IRR) when detecting signs associated with COVID-19 in the LUS, as well as the performance of the test in a longitudinal or transverse orientation. Thirty-three physicians with advanced experience in LUS independently evaluated ultrasound videos previously acquired using the ULTRACOV system on 20 patients with confirmed COVID-19. For each patient, 24 videos of 3 s were acquired (using 12 positions with the probe in longitudinal and transverse orientations). The physicians had no information about the patients or other previous evaluations. The score assigned to each acquisition followed the convention applied in previous studies. A substantial IRR was found in the cases of normal LUS (κ = 0.74), with only a fair IRR for the presence of individual B-lines (κ = 0.36) and for confluent B-lines occupying < 50% (κ = 0.26) and a moderate IRR in consolidations and B-lines > 50% (κ = 0.50). No statistically significant differences between the longitudinal and transverse scans were found. The IRR for LUS of COVID-19 patients may benefit from more standardized clinical protocols.
Chest X-ray (CXR) is the first tool globally employed to detect cardiopulmonary pathologies. These acquisitions are highly affected by scattered photons due to the large field-of-view required. Scatter in CXRs introduces background in the images, which reduces their contrast. We developed three deep learning-based models to estimate and correct the scatter contribution to CXRs. We used a Monte Carlo (MC) ray-tracing model to simulate CXRs from human models obtained from CT scans using different configurations (depending on the availability of dual-energy acquisitions). The simulated CXRs contained the separated contribution of direct and scattered X-rays in the detector. These simulated datasets were then used as the reference for the supervised training of several NN. Three NN models (single and dual energy) were trained with the MultiResUNet architecture. The performance of the NN models was evaluated on CXRs obtained with the MC code from chest CTs of patients affected by COVID-19. The results showed that the NN models were able to estimate and correct the scatter contribution to CXRs with an error <5%, being robust to variations in the simulation setup and improving the contrast in soft tissue. The single-energy model was tested with real CXRs, providing robust estimations of the scatter-corrected CXRs.
Chest X-rays (CXRs) represent the first tool globally employed to detect cardiopulmonary pathologies. These acquisitions are highly affected by scattered photons due to the large field of view required. Scatter in CXRs introduces background in the images, which reduces their contrast. We developed three deep-learning-based models to estimate and correct scatter contribution to CXRs. We used a Monte Carlo (MC) ray-tracing model to simulate CXRs from human models obtained from CT scans using different configurations (depending on the availability of dual-energy acquisitions). The simulated CXRs contained the separated contribution of direct and scattered X-rays in the detector. These simulated datasets were then used as the reference for the supervised training of several NNs. Three NN models (single and dual energy) were trained with the MultiResUNet architecture. The performance of the NN models was evaluated on CXRs obtained, with an MC code, from chest CT scans of patients affected by COVID-19. The results show that the NN models were able to estimate and correct the scatter contribution to CXRs with an error of <5%, being robust to variations in the simulation setup and improving contrast in soft tissue. The single-energy model was tested on real CXRs, providing robust estimations of the scatter-corrected CXRs.
Lung ultrasound (LUS) allows the detection of a series of manifestations of COVID-19 such as B lines and consolidations. The objective of this work was to study the inter-rater reliability (IRR) when detecting signs associated with COVID-19 in the LUS, as well as the impact of performing the test in the longitudinal or transverse orientation. 33 physicians with advanced experience in LUS, independently evaluated ultrasound videos previously acquired with the ULTRACOV system of 20 patients with confirmed COVID-19. In each patient, 24 videos of 3 seconds were acquired (using 12 positions with the probe in longitudinal and transverse orientations). Physicians had no information about the patients or other previous evaluations. The score assigned to each acquisition followed the convention applied in previous studies. A substantial IRR was found in the cases of normal LUS (κ = 0.74), only a fair IRR for the presence of individual B lines (κ = 0.36) and for confluent B lines occupying 50% (κ = 0.50). No statistically significant differences between the longitudinal and transverse scans were found. The IRR in LUS of COVID-19 patients may benefit from more standardization of the clinical protocols.