To determine if tinnitus was related to working memory (WM) in adults and if tinnitus handicap was related to WM in adults with tinnitus. Two groups, cross-sectional design. 76 adults forming a tin...
Degree of distress perceived due to tinnitus is different in every individual. Underlying mechanisms for this are yet unclear. Investigating the relationship between hearing status and tinnitus dis... 背景:每个人因耳鸣而感到的痛苦程度都不尽相同, 其潜在机制尚不清楚。 目的:探讨听力状态与耳鸣困扰的关系。 材料和方法:这是一项病例-对照研究。 38名耳鸣患者, 分为正常听力(NHT, n¼19)组和听力障碍(HIT, n¼19)组。两组年龄和性别匹配, 具有相似的教育背景、耳鸣持续时间和偏侧性。参加者进行了听力测评(0.125至16 kHz), 完成了医院焦虑和抑郁量表(HADS)和耳鸣...
Blue light (400–500 nm) alleviates overexposure risks associated to UV light and has therefore gained increased interest in multiple applications. This meta-analysis deals with decontamination of E. coli through the use of blue light based from nine recent publications identified via a systematic literature search. In these studies, various pathogenic and non-pathogenic E. coli strains grown in nutritional broths were exposed to wavelengths ranging from 395 to 460 nm. Five meta-analyses were performed using Cochrane’s software for meta-analyses (Review Manager): one including all studies to estimate the effect of E. coli reduction and four subgroup-analyses considering reported intensities, wavelengths, exposure dose as well as serovars/pathovars. Random effects models were used. All included studies used colony-forming units to estimate the impact of E. coli reduction. None of the included studies involved an organic matrix (e.g., skin, food related surface). Exposure to blue light had a significant and large reducing effect on viable counts of E. coli. However, substantial heterogeneity across studies was observed. Among subgroups, reported intensity and wavelength showed the clearest impact on E. coli reduction. With respect to the reported exposure dose, the picture across the spectrum was scattered, but effect sizes tend to increase with increasing exposure dose. Substantial heterogeneity was also present with respect to all serovar/pathovar subgroups among the included studies. The present body of reports does not display a strong basis for recommendation of relevant intensities, wavelengths and exposure doses for superficial blue light decontamination in medical or food safety contexts. A serious shortcoming in most studies is the absence of a clear documentation of inoculum preparation and of study parameters. We suggest improvement for study protocols for future investigations.
Research into the potential associations between tinnitus and cognition has investigated specific cognitive domains in laboratory settings despite adults with tinnitus reporting broad cognitive difficulties in every-day life. To address this limitation, the present study compared performance and perceived exertion on a visual office-like task in 38 adults with tinnitus (19 with normal hearing and 19 with hearing loss) and 38 adults without tinnitus (19 with normal hearing and 19 with hearing loss) matched for age, sex and educational background. All participants were also assessed for hearing, anxiety and depression, and participants with tinnitus were also assessed for tinnitus handicap. No associations were found between presence of tinnitus and cognitive performance (mean total rate correct score on the visual office-like task being 2.9 for the tinnitus group, 2.8 for the control group,p= 0.612) and perceived exertion (mean ratings of perceived exertion on the Borg CR10-scale being 5.8 for the tinnitus group, 6.5 for the control group,p= 0.063) on the visual office-like task when corrected for standard (0.125 to 8 kHz) and extended high frequency (10 to 16 kHz) hearing thresholds, anxiety, and depression. The correction for extended high frequency average (10, 12.5, 14, and 16 kHz) hearing threshold was significant for performance (p= 0.009) but not perceived exertion on the visual office-like task. Overall, the results showed extended high frequency hearing, but not tinnitus, was associated with every-day cognitive performance. This indicates clinical testing of hearing thresholds above 8 kHz could support clinicians’ identification and management of cognitive difficulties. One management method suggested by the current findings would include provision of auditory stimulation at frequencies exceeding the frequency response of many current hearing aids.
There is a consensus among tinnitus experts to not recommend hearing aids for tinnitus patients with subclinical hearing impairment. However, this notion is arbitrary, as no previous study has compared the treatment effect of hearing aids on tinnitus distress in patients with and without clinical hearing impairment. In this article, we investigate whether tinnitus patients with clinical and subclinical hearing impairment differ in terms of tinnitus mitigation after hearing aid fitting. Twenty-seven tinnitus patients with either clinical (n = 13) or subclinical (n = 14) hearing impairment were fitted with hearing aids. All participants filled out the tinnitus functional index (TFI) before hearing aid fitting and after 3 months of hearing aid use. Clinically meaningful reductions in tinnitus distress (−13 TFI points or more) were seen in both groups, and the difference in tinnitus mitigation between tinnitus patients with clinical (mean TFI reduction = 17.0 points) and subclinical hearing impairment (mean TFI reduction = 16.9 points) was not statistically significant (p = 0.991). Group differences on the suspected confounding factors of age, sex, time since tinnitus debut, tinnitus distress (TFI score) at baseline, and treatment adherence were statistically insignificant. In light of this, we argue that clinical hearing impairment is not required to achieve meaningful tinnitus mitigation with hearing aids, and that hearing aids could be recommended for tinnitus patients with subclinical hearing impairment.