Background: Pin tract infection is a common problem in orthopedic and traumatology surgery. The aim of this study was to investigate the efficacy of an implant coated with carboxymethyl chitosan–zinc (CMC-Zn2+) in prevention of pin tract infection. Materials and Methods: Twenty-four male New Zealand White rabbits were randomized into two equal groups ( n = 12, uncoated and CMC-Zn2+). The implants were colonized with 1 × 106 colony forming units of Staphylococcus aureus and inserted into the lateral right proximal tibia in each rabbit. In each group, at 2 and 4 weeks post-surgery, five and seven rabbits were killed, respectively, to harvest the soft tissues around the implant as well as the hard tissue for histological analysis. The bone cross-sectional view, X-ray, and micro-computed tomography (μCT) were performed. Results: The surgical sites in each animal were evaluated individually at both time points. No evident signs of infections were found in the CMC-Zn2+ group, while a high rate of infection was observed in the uncoated group where minor infections were 85.71% ( n = 12) and major infections 14.29% ( n = 12). The radiography, μCT, and histological analysis showed no evident signs of infection in both groups at 2 weeks post-surgery. However, at 4 weeks, signs of infection were found in all the animals in the uncoated group, whereas in the CMC-Zn2+ group, no infections were observed. The difference between the two groups was highly significant ( p = 0.00). Conclusions: Our study showed that CMC-Zn2+-coated implants were effective in preventing pin tract infection.
22 May 2022 in Journal of Shoulder and Elbow Surgery
Portable ultrasound is a modality of medical ultrasonography that utilizes small and light devices, and is an established diagnostic method used in clinical settings such as Cardiology, Vascular Surgery, Radiology, Endocrinology, Pediatric and Obstetric & Gynecology. We present a case report of 86-years old patient who underwent surgical rib fixation for multiple rib fractures followed by falling from standing height and our management experience. The use of portable ultrasound device in operation theatre demonstrates several advantages.We believe that Portable color doppler ultrasound system would be necessary in the management of rib fracture. This study demonstrates that the portable ultrasound system is a valuable method of imaging in the assessment of rib fractures, and which can save time, economically affordable for many patients, and allow surgeons to make a minor incision in order to avoid complications such as infection, particularly in this group of vulnerable patients.
Introduction Heel puncture (HP) in neonates can result in osteomyelitis if done non-aseptically or with incorrect technique. This study summarizes clinical experience with heel puncture-related osteomyelitis of the calcaneus (HP-CO) in newborns. Methods We systematically reviewed studies that examined HP-CO in newborn patients using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Our search included the PubMed, Embase, and Cochrane Library databases until December 31, 2023. We used the National Institutes of Health (NIH) assessment scale to evaluate the quality of our analyzed studies. Results This study analyzed 15 neonatal calcaneal osteomyelitis (CO) cases due to HP conducted in six countries from 1976 to 2016. The average age of the cases was 8.87 ± 6.13 days, with an average birth weight of 2367.27 ± 947.59 g. The infants had undergone an average of 9.00 ± 8.90 HP, with 93.33% exhibiting swelling. Staphylococcus aureus was present in 80% of cases. Beta-lactam antibiotics were used, with satisfactory outcomes in 53.33% of cases. However, in seven cases, three patients had flatfoot due to calcaneal deformity, and other complications were observed in some patients after 7–8 years. Conclusions This study offers valuable insights into a rare condition, including its epidemiology, clinical and laboratory characteristics, and treatment options for infants with HP-CO. To prevent the risk of osteomyelitis in this vulnerable group of patients, increasing awareness and maintaining strict aseptic techniques is necessary. We recommend that infants presenting with tenderness, redness, purulent discharge, erythema, or fever and with a history of repeated HP and swollen ankles should be evaluated for suspicion of osteomyelitis. A graphical abstract is avilable for this article. Graphical Abstract
[b]BACKGROUND[/b] The aim of this study was to investigate the in vivo efficacy of an implant coated with HTCC in prevention of pin tract infection, a major complication in orthopedic surgery, in comparison with an uncoated implant. [b]MATERIAL AND METHODS[/b] Twenty-four mature male white rabbits were randomized into 2 equal groups (N=12). HTCC-coated implants were used in the experimental group and uncoated implants in the control group. The implants were colonized with 1×106 colony-forming units (CFU) of [i]Staphylococcus aureus[/i] and inserted into the lateral aspect of the right proximal tibiae (1 implant per rabbit). In each group at 2 and 4 weeks after surgery, 5 and 7 rabbits were sacrificed, respectively, to harvest the soft tissues around the pin tract for histological analysis, radiographic examination, and gross observation of the surgical sites. [b]RESULTS[/b] After 4 weeks, 100% of the uncoated implants showed signs of infection, while 75% of the HTCC-coated implants were infected. [b]CONCLUSIONS[/b] HTCC coating was not effective in prevention of pin tract infection.