Marko Subašić

Prof. Marko Subašić

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
DMDuje Medak
Duje Medak
LPLuka Posilovic
Luka Posilovic
MSMarko Subašić
Marko Subašić
MBMarko Budimir
Marko Budimir
SLSven Loncaric
Sven Loncaric
Nondestructive evaluation (NDE) is a set of techniques used for material inspection and defect detection without causing damage to the inspected component. One of the commonly used nondestructive techniques is called ultrasonic inspection. The acquisition of ultrasonic data was mostly automated in recent years, but the analysis of the collected data is still performed manually. This process is thus very expensive, inconsistent, and prone to human errors. An automated system would significantly increase the efficiency of analysis, but the methods presented so far fail to generalize well on new cases and are not used in real-life inspection. Many of the similar data analysis problems were recently tackled by deep learning methods. This approach outperforms classical methods but requires lots of training data, which is difficult to obtain in the NDE domain. In this work, we train a deep learning architecture EfficientDet to automatically detect defects from ultrasonic images. We showed how some of the hyperparameters can be tweaked in order to improve the detection of defects with extreme aspect ratios that are common in ultrasonic images. The proposed object detector was trained on the largest dataset of ultrasonic images that was so far seen in the literature. In order to collect the dataset, six steel blocks containing 68 defects were scanned with a phased-array probe. More than 4000 VC-B-scans were acquired and used for training and evaluation of EfficientDet. The proposed model achieved 89.6% of mean average precision (mAP) during fivefold cross validation, which is a significant improvement compared to some similar methods that were previously used for this task. A detailed performance overview for each of the folds revealed that EfficientDet-D0 successfully detects all of the defects present in the inspected material.

15 March 2023 in Acta Stomatologica Croatica
Verified
Journal Article
Open access
MVMarin Vodanovic
Marin Vodanovic
MSMarko Subašić
Marko Subašić
DMDenis Milošević
Denis Milošević
IPIvana Savić Pavičin
Ivana Savić Pavičin
Artificial intelligence has been applied in various fields throughout history, but its integration into daily life is more recent. The first applications of AI were primarily in academia and government research institutions, but as technology has advanced, AI has also been applied in industry, commerce, medicine and dentistry. Considering that the possibilities of applying artificial intelligence are developing rapidly and that this field is one of the areas with the greatest increase in the number of newly published articles, the aim of this paper was to provide an overview of the literature and to give an insight into the possibilities of applying artificial intelligence in medicine and dentistry. In addition, the aim was to discuss its advantages and disadvantages. The possibilities of applying artificial intelligence to medicine and dentistry are just being discovered. Artificial intelligence will greatly contribute to developments in medicine and dentistry, as it is a tool that enables development and progress, especially in terms of personalized healthcare that will lead to much better treatment outcomes.

2 April 2022 in Ultrasonics
Verified
Journal Article
Closed access
LPLuka Posilović
Luka Posilović
DMDuje Medak
Duje Medak
FMFran Milković
Fran Milković
MSMarko Subašić
Marko Subašić
MBMarko Budimir
Marko Budimir
SLSven Lončarić
Sven Lončarić

1 February 2022 in Ultrasonics
Verified
Journal Article
Closed access
LPLuka Posilović
Luka Posilović
DMDuje Medak
Duje Medak
MSMarko Subašić
Marko Subašić
MBMarko Budimir
Marko Budimir
SLSven Lončarić
Sven Lončarić

9 December 2023 in Medicina
Verified
Journal Article
Open access
PDF file
MRMario Rašić
Mario Rašić
MTMario Tropčić
Mario Tropčić
PKPjetra Karlović
Pjetra Karlović
DGDragana Gabric
Dragana Gabric
MSMarko Subašić
Marko Subašić
PKPredrag Knežević
Predrag Knežević
Background and Objectives: The purpose of this study was to develop and evaluate a deep learning model capable of autonomously detecting and segmenting radiolucent lesions in the lower jaw by utilizing You Only Look Once (YOLO) v8. Materials and Methods: This study involved the analysis of 226 lesions present in panoramic radiographs captured between 2013 and 2023 at the Clinical Hospital Dubrava and the School of Dental Medicine, University of Zagreb. Panoramic radiographs included radiolucent lesions such as radicular cysts, ameloblastomas, odontogenic keratocysts (OKC), dentigerous cysts and residual cysts. To enhance the database, we applied techniques such as translation, scaling, rotation, horizontal flipping and mosaic effects. We have employed the deep neural network to tackle our detection and segmentation objectives. Also, to improve our model’s generalization capabilities, we conducted five-fold cross-validation. The assessment of the model’s performance was carried out through metrics like Intersection over Union (IoU), precision, recall and mean average precision (mAP)@50 and mAP@50-95. Results: In the detection task, the precision, recall, mAP@50 and mAP@50-95 scores without augmentation were recorded at 91.8%, 57.1%, 75.8% and 47.3%, while, with augmentation, were 95.2%, 94.4%, 97.5% and 68.7%, respectively. Similarly, in the segmentation task, the precision, recall, mAP@50 and mAP@50-95 values achieved without augmentation were 76%, 75.5%, 75.1% and 48.3%, respectively. Augmentation techniques led to an improvement of these scores to 100%, 94.5%, 96.6% and 72.2%. Conclusions: Our study confirmed that the model developed using the advanced YOLOv8 has the remarkable capability to automatically detect and segment radiolucent lesions in the mandible. With its continual evolution and integration into various medical fields, the deep learning model holds the potential to revolutionize patient care.

16 December 2020 in IEEE Access
Verified
Journal Article
Open access
EEEgor Ershov
Egor Ershov
ASAlexey Savchik
Alexey Savchik
ISIllya Semenkov
Illya Semenkov
NBNikola Banic
Nikola Banic
ABAlexander Belokopytov
Alexander Belokopytov
SLSven Loncaric
Sven Loncaric
Computational color constancy has the important task of reducing the influence of the scene illumination on the object colors. As such, it is an essential part of the image processing pipelines of most digital cameras. One of the important parts of the computational color constancy is illumination estimation, i.e. estimating the illumination color. When an illumination estimation method is proposed, its accuracy is usually reported by providing the values of error metrics obtained on the images of publicly available datasets. However, over time it has been shown that many of these datasets have problems such as too few images, inappropriate image quality, lack of scene diversity, absence of version tracking, violation of various assumptions, GDPR regulation violation, lack of additional shooting procedure info, etc. In this paper a new illumination estimation dataset is proposed that aims to alleviate many of the mentioned problems and to help the illumination estimation research. It consists of 4890 images with known illumination colors as well as with additional semantic data that can further make the learning process more accurate. Due to the usage of the SpyderCube color target, for every image there are two ground-truth illumination records covering different directions. Because of that, the dataset can be used for training and testing of methods that perform single or two-illuminant estimation. This makes it superior to many similar existing datasets. The datasets, it’s smaller version SimpleCube++, and the accompanying code are available at https://github.com/Visillect/CubePlusPlus/ .