Marlissa Becker

Ms. Marlissa Becker

Orthopedics and Sports Medicine - Physical Therapy, Erasmus University Medical Center, Rotterdam, Zuid-Holland, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2022 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
MGMarco Giurgiu
Marco Giurgiu
ITIrina Timm
Irina Timm
MBMarlissa Becker
Marlissa Becker
SSSteffen Schmidt
Steffen Schmidt
Kathrin WunschKathrin Wunsch
Kathrin Wunsch
BHBirte von Haaren-Mack
Birte von Haaren-Mack
Background: Wearable technology is a leading fitness trend in the growing commercial industry and an established method for collecting 24-hour physical behavior data in research studies. High-quality free-living validation studies are required to enable both researchers and consumers to make guided decisions on which study to rely on and which device to use. However, reviews focusing on the quality of free-living validation studies in adults are lacking. Objective: This study aimed to raise researchers’ and consumers’ attention to the quality of published validation protocols while aiming to identify and compare specific consistencies or inconsistencies between protocols. We aimed to provide a comprehensive and historical overview of which wearable devices have been validated for which purpose and whether they show promise for use in further studies. Methods: Peer-reviewed validation studies from electronic databases, as well as backward and forward citation searches (1970 to July 2021), with the following, required indicators were included: protocol must include real-life conditions, outcome must belong to one dimension of the 24-hour physical behavior construct (intensity, posture or activity type, and biological state), the protocol must include a criterion measure, and study results must be published in English-language journals. The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool with 9 questions separated into 4 domains (patient selection or study design, index measure, criterion measure, and flow and time). Results: Of the 13,285 unique search results, 222 (1.67%) articles were included. Most studies (153/237, 64.6%) validated an intensity measure outcome such as energy expenditure. However, only 19.8% (47/237) validated biological state and 15.6% (37/237) validated posture or activity-type outcomes. Across all studies, 163 different wearables were identified. Of these, 58.9% (96/163) were validated only once. ActiGraph GT3X/GT3X+ (36/163, 22.1%), Fitbit Flex (20/163, 12.3%), and ActivPAL (12/163, 7.4%) were used most often in the included studies. The percentage of participants meeting the quality criteria ranged from 38.8% (92/237) to 92.4% (219/237). On the basis of our classification tree to evaluate the overall study quality, 4.6% (11/237) of studies were classified as low risk. Furthermore, 16% (38/237) of studies were classified as having some concerns, and 72.9% (173/237) of studies were classified as high risk. Conclusions: Overall, free-living validation studies of wearables are characterized by low methodological quality, large variability in design, and focus on intensity. Future research should strongly aim at biological state and posture or activity outcomes and strive for standardized protocols embedded in a validation framework. Standardized protocols for free-living validation embedded in a framework are urgently needed to inform and guide stakeholders (eg, manufacturers, scientists, and consumers) in selecting wearables for self-tracking purposes, applying wearables in health studies, and fostering innovation to achieve improved validity.

28 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MBMarlissa Becker
Marlissa Becker
HHHenri L. P. Hurkmans
Henri L. P. Hurkmans
JVJan A. N. Verhaar
Jan A. N. Verhaar
JBJohannes BJ Bussmann
Johannes BJ Bussmann
Sedentary behaviors and low physical activity among hospitalized patients have detrimental effects on health and recovery. Wearable activity monitors are a promising tool to promote mobilization and physical activity. However, existing devices have limitations in terms of their outcomes and validity. The Activ8 device was optimized for the hospital setting. This study assessed the concurrent validity of the modified Activ8. Hospital patients performed an activity protocol that included basic (e.g., walking) and functional activities (e.g., room activities), with video recordings serving as the criterion method. The assessed outcomes were time spent walking, standing, upright, sedentary, and newly added elements of steps and transfers. Absolute and relative time differences were calculated, and Wilcoxon and Bland–Altman analyses were conducted. Overall, the observed relative time differences were lower than 2.9% for the basic protocol and 9.6% for the functional protocol. Statistically significant differences were detected in specific categories, including basic standing (p < 0.05), upright time (p < 0.01), and sedentary time (p < 0.01), but they did not exceed the predetermined 10% acceptable threshold. The modified Activ8 device is a valid tool for assessing body postures, motions, steps, and transfer counts in hospitalized patients. This study highlights the potential of wearable activity monitors to accurately monitor and promote PA among hospital patients.

6 September 2024 in Annals of Medicine
Verified
Journal Article
Open access
MBMarlissa Becker
Marlissa Becker
HHHenri L. Hurkmans
Henri L. Hurkmans
JVJan A.N. Verhaar
Jan A.N. Verhaar
JBJohannes B.J. Bussmann
Johannes B.J. Bussmann
Sensor technology could provide solutions to monitor postures and motions and to help hospital patients reach their rehabilitation goals with minimal supervision. Synthesized information on device applications and methodology is lacking. The purpose of this scoping review was to provide an overview of device applications and methodological approaches to monitor postures and motions in hospitalized patients using sensor technology. A systematic search of Embase, Medline, Web of Science and Google Scholar was completed in February 2023 and updated in March 2024. Included studies described populations of hospitalized adults with short admission periods and interventions that use sensor technology to objectively monitor postures and motions. Study selection was performed by two authors independently of each other. Data extraction and narrative analysis focused on the applications and methodological approaches of included articles using a personalized standard form to extract information on device, measurement and analysis characteristics of included studies and analyse frequencies and usage. A total of 15.032 articles were found and 49 articles met the inclusion criteria. Devices were most often applied in older adults (n = 14), patients awaiting or after surgery (n = 14), and stroke (n = 6). The main goals were gaining insight into patient physical behavioural patterns (n = 19) and investigating physical behaviour in relation to other parameters such as muscle strength or hospital length of stay (n = 18). The studies had heterogeneous study designs and lacked completeness in reporting on device settings, data analysis, and algorithms. Information on device settings, data analysis, and algorithms was poorly reported. Studies on monitoring postures and motions are heterogeneous in their population, applications and methodological approaches. More uniformity and transparency in methodology and study reporting would improve reproducibility, interpretation and generalization of results. Clear guidelines for reporting and the collection and sharing of raw data would benefit the field by enabling study comparison and reproduction.

12 January 2022 in JMIR Preprints
Verified
Preprint
Open access
MGMarco Giurgiu
Marco Giurgiu
ITIrina Timm
Irina Timm
MBMarlissa Becker
Marlissa Becker
SSSteffen Schmidt
Steffen Schmidt
Kathrin WunschKathrin Wunsch
Kathrin Wunsch
BHBirte von Haaren-Mack
Birte von Haaren-Mack
BACKGROUND Wearable technology is a leading fitness trend in the growing commercial industry and an established method for collecting 24-hour physical behavior data in research studies. High-quality free-living validation studies are required to enable both researchers and consumers to make guided decisions on which study to rely on and which device to use. However, reviews focusing on the quality of free-living validation studies in adults are lacking. OBJECTIVE This study aimed to raise researchers’ and consumers’ attention to the quality of published validation protocols while aiming to identify and compare specific consistencies or inconsistencies between protocols. We aimed to provide a comprehensive and historical overview of which wearable devices have been validated for which purpose and whether they show promise for use in further studies. METHODS Peer-reviewed validation studies from electronic databases, as well as backward and forward citation searches (1970 to July 2021), with the following, required indicators were included: protocol must include real-life conditions, outcome must belong to one dimension of the 24-hour physical behavior construct (intensity, posture or activity type, and biological state), the protocol must include a criterion measure, and study results must be published in English-language journals. The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool with 9 questions separated into 4 domains (patient selection or study design, index measure, criterion measure, and flow and time). RESULTS Of the 13,285 unique search results, 222 (1.67%) articles were included. Most studies (153/237, 64.6%) validated an intensity measure outcome such as energy expenditure. However, only 19.8% (47/237) validated biological state and 15.6% (37/237) validated posture or activity-type outcomes. Across all studies, 163 different wearables were identified. Of these, 58.9% (96/163) were validated only once. ActiGraph GT3X/GT3X+ (36/163, 22.1%), Fitbit Flex (20/163, 12.3%), and ActivPAL (12/163, 7.4%) were used most often in the included studies. The percentage of participants meeting the quality criteria ranged from 38.8% (92/237) to 92.4% (219/237). On the basis of our classification tree to evaluate the overall study quality, 4.6% (11/237) of studies were classified as low risk. Furthermore, 16% (38/237) of studies were classified as having some concerns, and 72.9% (173/237) of studies were classified as high risk. CONCLUSIONS Overall, free-living validation studies of wearables are characterized by low methodological quality, large variability in design, and focus on intensity. Future research should strongly aim at biological state and posture or activity outcomes and strive for standardized protocols embedded in a validation framework. Standardized protocols for free-living validation embedded in a framework are urgently needed to inform and guide stakeholders (eg, manufacturers, scientists, and consumers) in selecting wearables for self-tracking purposes, applying wearables in health studies, and fostering innovation to achieve improved validity. CLINICALTRIAL