Jin-feng Zeng

Jin-feng Zeng


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2019 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
XYXianlin Ye
Xianlin Ye
TLTong Li
Tong Li
WSWen Shao
Wen Shao
JZJin-feng Zeng
Jin-feng Zeng
WHWenxu Hong
Wenxu Hong
TLTingting Li
Tingting Li
Blood donor plasma samples were detected by the Ultrio Plus NAT system for HBV, HCV and HIV-1 in Shenzhen blood center, China. Reactive samples underwent further discriminatory testing of a single virus by the same methodology. A large number of cases of non-discriminated reactive (NDR) donors were found, leaving potential risk of transmitting HBV if not deferrals. This study identified those non-discriminated samples. The NDR plasma samples from blood donation screening were detected and classified by additional molecular and serological tests. Molecular characterizations of DNA+ NDR were determined by sequencing analysis. A number of 259 (0.21%) NDR plasma samples from screening of 123,280 eligible blood donors were detected, which presented a higher rate (91.1%) of anti-HBc reactivity and nearly half (46.7%) of HBV DNA+ that classified as occult HBV infection (OBI). Most OBI strains were wild-type HBV, but some substitutions V168A, S174 N, V177A, Q129R/L/H, G145A/R in S region of genotype B (OBIB) and T47K/V/A, P49H/L, Q101R/H/K, S174 N, L175S, V177A, T118 M/R/K, G145R/A/K/E, R160K/N in S region of genotype C (OBIC) strains were identified in high frequency. Nearly half of NDR blood samples were identified as OBI, in which a number of important mutations were detected. NDR donation might have potential risk for HBV transmission, but need to be further investigated.

6 August 2020 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
JZJunpeng Zhao
Junpeng Zhao
FZFeixue Zhao
Feixue Zhao
WHWei Han
Wei Han
XXXiaoxuan Xu
Xiaoxuan Xu
LWLilin Wang
Lilin Wang
LWLunan Wang
Lunan Wang
Background: Human T-cell lymphotropic virus (HTLV) remains a major safety concern for blood supplies. Despite many HTLV positive cases being reported in southeastern China, the detection of HTLV has not been prioritized in routine blood screening. Additionally, data on the prevalence of HTLV infection among blood donors is also limited. The objective of this study was to investigate the prevalence of HTLV among blood donors in three Chinese provinces through their representative blood centers, to evaluate the feasibility of chemiluminescence immunoassay (CLIA) for blood screening. Methods: From November 2018 to March 2019, blood plasma samples were collected from Hebei, Changsha, and Shenzhen blood centers and were screened for the HTLV-1/2 antibody using a CLIA and enzyme-linked immunosorbent assay (ELISA). This was followed by confirmatory tests using INNO-LIA HTLV I/II. Results: A total of 59,929 blood donations were collected and screened for HTLV-1/2. The reactive rate of CLIA and ELISA among donations in the Shenzhen blood center (0.0943%, 27/28,621) was higher than Hebei (0.0248%, 4/16,144), and Changsha (0.0198%, 3/15,164) (p < 0.05). After confirmation, 3 samples were confirmed as indeterminate for HTLV antibodies, and only one sample from the Shenzhen blood center was confirmed as HTLV-1. The overall prevalence of HTLV-1/2 was 1.67 per 100,000 (1/59,929). The HTLV-infected blood came from a 32-year-old first-time female donor with a high school degree, who belonged to the SHE ethnic minority and was born in the Fujian province. Conclusions: In summary, the overall prevalence of HTLV-1/2 among blood donors in the three blood centers in China remains relatively low. However, blood donations with positive or indeterminate results for HTLV antibodies reminded us of the importance of HTLV screening among blood donors in China.

19 January 2021 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
XYXianlin Ye
Xianlin Ye
TLTong Li
Tong Li
RLRan Li
Ran Li
HLHeng Liu
Heng Liu
JZJunpeng Zhao
Junpeng Zhao
JZJin-feng Zeng
Jin-feng Zeng
Background: Hepatitis B virus (HBV) infection is a major concern for blood safety in high-prevalence HBV countries such as China. In Shenzhen, dual hepatitis B surface antigen (HBsAg) enzyme-linked immunosorbent assays (ELISAs) have been adopted in parallel with nucleic acid testing (NAT) for donors for over a decade. A small proportion of blood donors test reactive (R) for HBsAg but negative through routine NAT, which can lead to HBV infection with an extremely low viral load. Objectives: We aimed to investigate and analyze the molecular characteristics of HBV among blood donors that tested HBsAg R in a single ELISA test. Methods: Blood donations were evaluated in this study if confirmed HBsAg R through one of two ELISA kits. Samples with non-reactive (NR) results by NAT were collected and tested for HBsAg by chemiluminescent microparticle immunoassay (CLIA) with a neutralization test. The level of HBsAg was further assessed by electrochemiluminescence immunoassay (ECLIA). The viral basic core promoter (BCP) and pre-core (PC) and S regions were amplified by nested PCR. Quantitative real-time PCR (qPCR) for viral load determination and individual donation (ID)-NAT were adopted simultaneously. HBsAg was confirmed with CLIA, ECLIA, nested PCR, qPCR, and ID-NAT. Results: Of the 100,252 donations, 38 and 41 were identified as HBsAg R with Wantai and DiaSorin ELISA kits, respectively. Seventy-nine (0.077%, 79/100,252) blood samples with ELISA R-NR and NAT NR results were enrolled in the study. Of these, 17 (21.5%,17/79) were confirmed as HBsAg-positive. Of the 14 genotyped cases, 78.6% (11/14) were genotype B, and C and D were observed in two and one sample, respectively. Mutations were found in the S gene, including Y100C, Y103I, G145R, and L175S, which can affect the detection of HBsAg. A high-frequency mutation, T1719G (93.3%), was detected in the BCP/PC region, which reduced the viral replication. Conclusion: A small number of blood samples with HBsAg ELISA R-NR and NAT NR results were confirmed as HBV infection, viral nucleic acids were found in most of the samples through routine NAT methods. It is necessary to employ more sensitive and specific assays for the detection of HBV infection among blood donors.

1 February 2023 in International Journal of General Medicine
Verified
Journal Article
Open access
PDF file
SWSong-Xing Wang
Song-Xing Wang
LSLi-Yan Sun
Li-Yan Sun
QYQiong Yu
Qiong Yu
TLTong Li
Tong Li
RLRan Li
Ran Li
JZJin-feng Zeng
Jin-feng Zeng
Background: New HIV (Human immune deficiency virus) infections are continuously increasing in China and it remains a huge challenge to blood donation. As access to health services has affected by COVID-19 (Corona virus disease 2019) pandemic, a drop in new diagnoses (especially HIV) was observed worldwide. Methods: During 2013– 2021, 735,247 specimens from unpaid blood donors collected by Shenzhen Blood Center underwent ELISA (Enzyme -linked immunosorbent assay) and NAT (Nucleic acid test). Samples with reactivity results were sent to the Shenzhen Center for Disease Control and Prevention for WB (Western blot). All data were statistically analyzed by the Chi-Square test. Results: From 2013 to 2021, the prevalence of HIV among male blood donors was higher than in females (P < 0.01). During the COVID-19 pandemic, the prevalence of HIV among repeat blood donors decreased significantly compared to 2019 (P < 0.05), and the characteristics of blood donors changed in 2020 compared to 2019 and 2021. Conclusion: The high proportion of female blood donors would help prevent HIV from getting into the blood supply. The COVID-19 pandemic affected the demographics of blood donors as well as the prevalence of HIV among repeat blood donors. An increased number of repeat blood donors can help decrease the risk of HIV transfusion transmission during the epidemic.

14 July 2020 in medRxiv
Verified
Preprint
Open access
PDF file
LCLe Chang
Le Chang
WHWangheng Hou
Wangheng Hou
LZLei Zhao
Lei Zhao
YZYali Zhang
Yali Zhang
YWYanbin Wang
Yanbin Wang
LWLunan Wang
Lunan Wang
Objectives: The prevalence of antibodies to SARS-CoV-2 among blood donors in China remains unknown. To reveal the missing information, we investigated the seroprevalence of SARS-CoV-2 antibodies among blood donors in the cities of Wuhan, Shenzhen, and Shijiazhuang of China. Design: Cross-sectional study Setting: Three blood centers, located in the central, south and north China, respectively, recruiting from January to April 2020. Participants: 38,144 healthy blood donors donated in Wuhan, Shenzhen and Shijiazhuang were enrolled, who were all met the criteria for blood donation during the COVID-19 pandemic in China. Main outcome measures: Specific antibodies against SARS-CoV-2 including total antibody (TAb), IgG antibody against receptor-binding domain of spike protein (IgG-RBD) and nucleoprotein (IgG-N), and IgM. Pseudotype lentivirus-based neutralization test was performed on all TAb-positive samples. In addition, anonymous personal demographic information, including gender, age, ethnicity, occupation and educational level, and blood type were collected. Results: A total of 519 samples from 410 donors were confirmed by neutralization tests. The SARS-CoV-2 seroprevalence among blood donors was 2.29% (407/17,794, 95%CI: 2.08% to 2.52%) in Wuhan, 0.029% (2/6,810, 95%CI: 0.0081% to 0.11%) in Shenzhen, and 0.0074% (1/13,540, 95%CI: 0.0013% to 0.042%) in Shijiazhuang, respectively. The earliest emergence of SARS-CoV-2 seropositivity in blood donors was identified on January 20, 2020 in Wuhan. The weekly prevalence of SARS-CoV-2 antibodies in Wuhan’s blood donors changed dynamically and were 0.08% (95%CI: 0.02% to 0.28%) during January 15 to 22 (before city lockdown), 3.08% (95%CI: 2.67% to 3.55%) during January 23 to April 7 (city quarantine period) and 2.33% (95%CI: 2.06% to 2.63%) during April 8 to 30 (after lockdown easing). Female and older-age were identified to be independent risk factors for SARS-CoV-2 seropositivity among donors in Wuhan. Conclusions: The prevalence of antibodies to SARS-CoV-2 among blood donors in China was low, even in Wuhan city. According to our data, the earliest emergence of SARS-CoV-2 in Wuhan’s donors should not earlier than January, 2020. As most of the population of China remained uninfected during the early wave of COVID-19 pandemic, effective public health measures are still certainly required to block viral spread before a vaccine is widely available.

28 November 2025 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
LSLiyan Sun
Liyan Sun
RLRan Li
Ran Li
SCSiqi Cai
Siqi Cai
SWSongxing Wang
Songxing Wang
JZJin-feng Zeng
Jin-feng Zeng
Objective: This study aimed to investigate the recovery efficiency and functional characteristics of lymphocytes isolated from leukocyte filters, compared with those isolated directly from whole blood sample, and to assess their potential as an alternative immune cell source for therapeutic applications. Methods: From December 2023 to 2024, leukocyte filters and 5 mL whole blood samples were collected from healthy donors. Cell recovery was optimized by testing different flushing methods (forward/reverse), solutions (1 × PBS/NS), and volumes (20 – 80 mL). Peripheral blood mononuclear cells (PBMCs) were isolated via density gradient centrifugation, and lymphocyte subsets (CD3 + CD56 + NK, CD3 + CD4 + T, CD3 + CD8 + T cells) were analyzed by flow cytometry. Transcriptome sequencing was conducted to evaluate functional differences. Results: Reverse flushing with 40 mL normal saline (NS) achieved cost-effective lymphocyte recovery, with cell counts correlating with flushing method and volume. The proportion of CD3 + CD4 + T cells in 40 mL NS was higher than that in whole blood samples ( P < 0.05), while CD3 + CD8 + T cells was lower ( P < 0.01). CD3 + CD4 + T cells exhibited the highest recovery efficiency, and CD3 + CD8 + T cells the lowest. Transcriptome analysis identified 634 differentially expressed genes, however, GO/KEGG enrichment analysis revealed no significant pathways related to NK or T cell functions ( P -adjust > 0.05). Conclusion: Reverse flushing of leukocyte filters with 40 mL NS enables cost-effective recovery of lymphocytes, particularly CD3 + CD4 + T cells. The recovered NK and T cells exhibit functional equivalence to those from those from whole blood samples, offering a low-cost and sustainable cell source for allogeneic cell therapy.