Dual-energy CT has shown promising results in determining tumor characteristics and treatment effectiveness through spectral data by assessing normalized iodine concentration (nIC), normalized effective atomic number (nZeff), normalized electron density (nED), and extracellular volume (ECV). This study explores the value of quantitative parameters in contrast-enhanced dual-layer spectral detector CT (SDCT) as a potential tool for detecting lymph node activity in lymphoma patients. A retrospective analysis of 55 lymphoma patients with 289 lymph nodes, assessed through 18FDG-PET/CT and the Deauville five-point scale, revealed significantly higher values of nIC, nZeff, nED, and ECV in active lymph nodes compared to inactive ones (p < 0.001). Generalized linear mixed models showed statistically significant fixed-effect parameters for nIC, nZeff, and ECV (p < 0.05). The area under the receiver operating characteristic curve (AUROC) values of nIC, nZeff, and ECV reached 0.822, 0.845, and 0.811 for diagnosing lymph node activity. In conclusion, the use of g nIC, nZeff, and ECV as alternative imaging biomarkers to PET/CT for identifying lymph node activity in lymphoma holds potential as a reliable diagnostic tool that can guide treatment decisions.
This study aims to propose and evaluate DR-CycleGAN, a disentangled unsupervised network by introducing a novel content-consistency loss, for removing arterial-phase motion artifacts in gadoxetic acid-enhanced liver MRI examinations. From June 2020 to July 2021, gadoxetic acid-enhanced liver MRI data were retrospectively collected in this center to establish training and testing datasets. Motion artifacts were semi-quantitatively assessed using a five-point Likert scale (1 = no artifact, 2 = mild, 3 = moderate, 4 = severe, and 5 = non-diagnostic) and quantitatively evaluated using the structural similarity index (SSIM) and peak signal-to-noise ratio (PSNR). The datasets comprised a training dataset (308 examinations, including 58 examinations with artifact grade = 1 and 250 examinations with artifact grade ≥ 2), a paired test dataset (320 examinations, including 160 examinations with artifact grade = 1 and paired 160 examinations with simulated motion artifacts of grade ≥ 2), and an unpaired test dataset (474 examinations with artifact grade ranging from 1 to 5). The performance of DR-CycleGAN was evaluated and compared with a state-of-the-art network, Cycle-MedGAN V2.0. As a result, in the paired test dataset, DR-CycleGAN demonstrated significantly higher SSIM and PSNR values and lower motion artifact grades compared to Cycle-MedGAN V2.0 (0.89 ± 0.07 vs. 0.84 ± 0.09, 32.88 ± 2.11 vs. 30.81 ± 2.64, and 2.7 ± 0.7 vs. 3.0 ± 0.9, respectively; p < 0.001 each). In the unpaired test dataset, DR-CycleGAN also exhibited a superior motion artifact correction performance, resulting in a significant decrease in motion artifact grades from 2.9 ± 1.3 to 2.0 ± 0.6 compared to Cycle-MedGAN V2.0 (to 2.4 ± 0.9, p < 0.001). In conclusion, DR-CycleGAN effectively reduces motion artifacts in the arterial phase images of gadoxetic acid-enhanced liver MRI examinations, offering the potential to enhance image quality.