According to its various features, the solar photovoltaics (PV) system is realized as a significant promising energy source to cope with energy shortcomings and environmental impacts like contamination. Therefore, it is mandatory to estimate and predict the output power for prediction intervals to avoid any power outage or urgent disturbances in the utility grid. These are challenging tasks as the solar PV output power depends on the weather variables data such as temperature and solar radiation. In this article, the estimation and forecast of solar PV output power are investigated with an upscaling method using three different types of artificial neural networks (ANNs) in order to reduce the estimation errors in current types of ANNs. The multilayer feedforward neural network (MLFFNN), recurrent neural network (RNN), and nonlinear autoregressive exogenous (NARX) model neural network (NARXNN) are applied to estimate and forecast the total output power of four real solar PV substations in Egypt. Hence both the surface temperature and the solar radiation of each PV substation are applied as the inputs of each designed NN, whereas the total output power of the four PV substations is its output. For the training and effectiveness investigation procedures of each applied ANNs, the data of two months (60 days) are attained and collected from these four PV substations. Here, the data of the first 45 days are applied to train the three designed NNs, while the data from the remaining 15 days, which are not applied for the training, are used to check the effectiveness and the generalization capability of the trained NNs. Hence, the estimation process is considered a prior step for the forecast of the output power. Therefore, upscaling method is utilized for assessing and forecasting a regional solar PV output power because of the limited number of monitored plants and applied data. The results provide evidence that the trained NNs are running very well and efficiently to estimate the power correctly. The performance of the MLFFNN is the best compared with the other NNs, whereas the NARXNN’s performance is the lowest one. The MLFFNN achieves the lowest mean squared error (MSE) of 0.27533 and the lowest absolute approximation error of 0.2099 MWh. Finally, the assessment and comparison among the three trained NNs and other techniques in recently published articles are highlighted and presented which reveal the performance superiority of the three trained NNs compared to other ANNs.
24 October 2015 in Signal, Image and Video Processing
In this pilot study, we evaluate the diagnostic accuracy and feasibility of utilizing smartphone-connected electrophysiological biosensors for measuring blood glucose level (BGL) in a type-2 diabetic (T2D) patient using machine learning (ML). Patients’ electrophysiological parameters are measured using commercially available, smartphone operated/embedded electrocardiography (ECG) and photoplethysmography (PPG) biosensors; simultaneously, we measure the BGL of the patient using a minimal invasive (MI) biosensor mounted on the patient’s arm. Statistical correlation analysis confirms that a modest correlation exists between the extracted ECG and PPG features and the measured BGL. The efficacy of ML models trained using the regression tree algorithm utilizing ECG and PPG extracted features for predicting the BGL is investigated. Experimental results show that ECG and PPG feature trained ML models can successfully predict BGL upto ± (8–33 mg/dL) during fasting, pre-prandial, and post-prandial intervals.
An efficient optical modulation technique for multi-input multi-output (MIMO) orthogonal frequency division multiplexing (OFDM) visible light communication system is proposed in this paper. The proposed modulation technique is termed as extended spatial-index light-emitting diode (LED) modulation. In the proposed technique, the indices (the spatial domain) of the LEDs are exploited in a dynamic style to not only get rid of the optical OFDM time-domain ( ) shaping problem but also to expand the LED indices spatial modulation domain. The indices of the active LEDs in the proposed technique are changed from the two LEDs active situation to the situation where all or several LEDs are active. Moreover, within the selected active LED indices, the power weight distribution and the positions of the OFDM components are varied to expand the resultant spatial domain. Therefore, the proposed technique offers a considerable spectral efficiency improvement over the up-to-date LED index OFDM modulation schemes even with a lower number of LEDs. The key idea of the proposed technique is to maximize the LEDs’ indices spatial position (spatial domain) utilization, where both the power weight allocation and the positions of the complex OFDM time domain components are varying several times over the same active LED indices combination, which improve the optical system spectral efficiency. The simulation results asserted the superiority of the proposed technique, as it improves both the average bit error rate (ABER) and the achievable data rate (R) compared with existing up-to-date OFDM-LED index modulations with even lower computational complexity.
15 July 2021 in IEEE Canadian Journal of Electrical and Computer Engineering
Speech signals typically have a stationary interval of 20-30 ms. Due to this, most speech processing techniques split speech signals into segments shorter than the stationary interval to take advantage of the piecewise stationary property of speech. However, there is no way to guarantee that the segments coincide with the stationary timescales inherent in the signal. Furthermore, how do we analyze speech signals over lengths longer than the stationary time scales? Second, there is evidence of the presence of nonlinearities in speech data from the published literature. In this article, the analysis of speech signals, without restriction to stationary time scales, using empirical mode decomposition (EMD) is presented in which the signal is broken down into components called intrinsic mode functions. EMD is especially suited for nonstationary and nonlinear data. The utility of this method, its effects, and opportunities for further research in the context of speech signals are presented.
The smart grid system is an ideal solution to overcome the limitations of traditional grid systems. A system is considered smart if it has smart in all its parts such as smart generation, smart transmission and distribution, smart control, smart metering, and …etc. In this paper, smart transmission and distribution have been presented to achieve the requirements of the smart grid system. By transferring to the smart grid, all utilities catch a lot of benefits such as increasing reliability, efficiency, and safety. On other hand, the operation cost will be decreased. In addition fast dynamic response for fault detection and isolation based on automatic Internet of Things (IoT) and wireless control. It should be noted that in the smart grids, the security of the system and occupational safety will be greatly increased. The system has been validated under different kinds of faults such as single-line to ground fault, and double-line to ground fault. In addition, the theoretical operation has been tested via MATLAB Simulink software.